• 제목/요약/키워드: Axial-type turbine

검색결과 81건 처리시간 0.025초

축류형 터빈에서 정${\cdot}$동익 축방향 거리의 변화에 대한 실험적 연구 (An Experimental Study of 3-D Axial Type Turbine Performance with Various Axial Gaps between the Rotor and Stator)

  • 김종호;김은종;조수용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.541-544
    • /
    • 2002
  • The turbine performance test of an axial-type turbine is carried out with various axial gap distances between the stator and rotor. The turbine is operated at the low pressure and speed, and the degree of reaction is 0.373 at the mean radius. The axial-type turbine consists of ons-stage and 3-dimensional blades. The chord length of rotor is 28.2mm and mean diameter of turbine is 257.56mm. The power of turbo-blower for input power is 30kW and mass flow rate is $340m^3/min\;at\;290mmAq$ static-pressure. The RPM and output power are controlled by a dynamometer connected directly to the turbine shaft. The axial gap distances are changed from a quarter to two times of stator axial chord length, and performance curves are obtained with 7 different axial gaps. The efficiency is dropped about $5{\%}$ of its highest value due to the variation of axial gap on the same non-dimensional mass flow rate and RPM, and experimental results show that the optimum axial gap is 1.0-1.5Cx.

  • PDF

정.동익 축방향 간격에 따른 단단 축류터빈의 성능시험에 관한 연구 (A Study of the One-Stage Axial Turbine Performance with Various Axial Gap Distances between the Stator and Rotor)

  • 김동식;조수용
    • 한국항공우주학회지
    • /
    • 제30권4호
    • /
    • pp.99-105
    • /
    • 2002
  • 본 연구에서는 정익과 동익간의 축방향 간격을 달리하여 축류형 터빈에서의 성능시험을 수행하였다. 실험에 사용된 터빈은 저압저속터빈으로써 평균반경에서 반동도가 0.373이며 축류형 3차원 단단터빈이다. 터빈의 평균반경 직경은 257.56mm이며 평균반경에서 동익의 익현은 28.2mm이다. 성능시험을 위한 공기력 입력장치로는 풍동이 사용되었으며 풍동의 터보블로워 동력은 30kW로써 290mmAq의 정압력에서 $340m^3$/min의 공기량을 보낼 수 있다. 터빈에서의 회전수 및 출력은 터빈 축에 직결식으로 연결된 다이나모메터에서 제어되었다. 실험에서 축방향 간격조정은 평균반경에서의 정익 축방향 익현의 1/4에서 3배까지 변경하여 총 9개의 성능시험을 수행하였다. 같은 무차원 유량과 RPM에서 축방향의 간격에 따른 효율의 변화는 최대 8%이내지만 최고효율을 얻게되는 축방향 간격은 1.6-1.9Cx 였다.

부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구 (Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine)

  • 조종현;조수용;최상규
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.324-330
    • /
    • 2005
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

  • PDF

부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구 (Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine)

  • 조종현;최상규;조수용
    • 한국유체기계학회 논문집
    • /
    • 제9권4호
    • /
    • pp.13-19
    • /
    • 2006
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

축류형 3차원 터빈익형의 성능시험장치 개발 (Development of a Test Rig for Three-Dimensional Axial-Type Turbine Blade)

  • 장범익;김동식;조수용;김수용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.453-460
    • /
    • 2000
  • A test rig is developed for performance test of 1 stage axial-type turbine which is designed by meanline analysis, streamline curvature method, and blade design method using configuration parameters. The purpose of this study is to find the best configuration parameters for designing a high efficiency axial-type turbine blade. To measure the efficiency of turbine stage, a dynamo-meter is installed. Two different stators which are manufactured as an integrated type are developed, and a rotor blade and 5 sets disc are developed for setting different stagger angle. The tip and hub diameters of the test turbine are 300 and 206.4mm, respectively. The rotating speed is 1800RPM, and the extracted power is 2.5kW. Flow coefficient is 1.68 and the reaction factor at meanline is 0.373. The number of stator and rotor of test turbine are 31 and 41, respectively. The Mach number of stator exit flow near hub is 0.164.

  • PDF

3차원 축류형 터빈익형의 공력설계에 관한 연구 (A Study on the Aerodynamic Design of Three-Dimensional Axial Type Turbine Blade)

  • 장범익;김동식;조수용
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.38-47
    • /
    • 2001
  • One stage axial type turbine is designed by mean-line analysis, streamline curvature method and blade design method using shape parameters. Tip and hub diameter of the turbine are 300mm and 206.4mm, respectively. The rotating speed is 1800RPM, and the output power is 1.4kW. The flow coefficient is 1.68 and the reaction factor at mean-line is 0.373. The number of stator and rotor of the turbine are 31 and 41, respectively. Mach number of stator exit flow near hub is 0.164. A test rig is developed for performance test to validate a developed design method. The experimental result shows that the maximum efficiency is obtained on the design point.

  • PDF

소형축류형 터빈에서의 부분분사 유동특성에 관한 연구 (An Experimental Study of Partial Admitted Flow Characteristics on a Small Axial-Type Turbine)

  • 조종현;조수용;최상규
    • 한국유체기계학회 논문집
    • /
    • 제7권6호
    • /
    • pp.28-37
    • /
    • 2004
  • An experimental study is conducted to investigate flow characteristics on a small axial-type turbine which is applied as the rotating part of air tools. It operates in a partial admission due to consumption restriction of the high pressure air. In this operating condition, it is necessary to understand flow characteristics for obtaining the high specific output power. Tested turbine consists of two stages and the mean radius of flow passage is less than 10mm. A 6 bar pressure air is used to operate the turbine. The experimental results show that flow angles depend on the measuring location along the circumferential direction, but its discrepancy is alleviated along the axial direction. Absolute flow velocities show three times difference according to the measuring location at the exit of the first rotor due to the partial admission, but they show similar value at the exit of the second rotor by the velocity diffusion. From the measured flow angles and velocities, a ratio of output power obtained by the first and second rotor is estimated. It shows that the output power obtained by the second rotor is about $11\%$ to that by the first rotor at 60,000 RPM. It is effective therefore to improve the first rotor for increasing the turbine output power.

증기가 분사된 축류형 터빈의 성능해석에 관한 연구 (Study on the Performance Analysis of an Axial-Type Turbine with Steam Injection)

  • 조수용;김수용
    • 한국유체기계학회 논문집
    • /
    • 제4권4호
    • /
    • pp.28-36
    • /
    • 2001
  • Performance analysis is conducted on an axial-type turbine which is used for fire extinction by injecting water or steam into the turbine. Loss models developed by Hacker and Okapuu are applied for predicting the performance of turbine. Pressure loss generated through a turbine is converted to the thermal efficiency, and thermal and gas properties are calculated within a turbine passage. Total-to-total efficiency, total-to-static efficiency, static temperature at the exit of turbine, output power, flow coefficient, blade loading coefficient, and expansion ratio are predicted with changing the amount of injected steam and the rotational speed. The 74 kW class gas turbine developed at KIMM is chosen for performance analysis. The 74 kW class turbine consists of 1 stage like a current developing gas turbine for fire extinction. Water or steam is injected at the end of combustor, and results show that efficiency and output power are dependent on the temperature of injected water or steam and the static temperature at the exit is decreased.

  • PDF

A Study on an Axial-Type 2-D Turbine Blade Shape for Reducing the Blade Profile Loss

  • Cho, Soo-Yong;Yoon, Eui-Soo;Park, Bum-Seog
    • Journal of Mechanical Science and Technology
    • /
    • 제16권8호
    • /
    • pp.1154-1164
    • /
    • 2002
  • Losses on the turbine consist of the mechanical loss, tip clearance loss, secondary flow loss and blade profile loss etc.,. More than 60 % of total losses on the turbine is generated by the two latter loss mechanisms. These losses are directly related with the reduction of turbine efficiency. In order to provide a new design methodology for reducing losses and increasing turbine efficiency, a two-dimensional axial-type turbine blade shape is modified by the optimization process with two-dimensional compressible flow analysis codes, which are validated by the experimental results on the VKI turbine blade. A turbine blade profile is selected at the mean radius of turbine rotor using on a heavy duty gas turbine, and optimized at the operating condition. Shape parameters, which are employed to change the blade shape, are applied as design variables in the optimization process. Aerodynamic, mechanical and geometric constraints are imposed to ensure that the optimized profile meets all engineering restrict conditions. The objective function is the pitchwise area averaged total pressure at the 30% axial chord downstream from the trailing edge. 13 design variables are chosen for blade shape modification. A 10.8 % reduction of total pressure loss on the turbine rotor is achieved by this process, which is same as a more than 1% total-to-total efficiency increase. The computed results are compared with those using 11 design variables, and show that optimized results depend heavily on the accuracy of blade design.

소형 축류 공압 터빈 공력 설계 및 수치 해석 (AERODYNAMIC DESIGN AND NUMERICAL ANALYSIS OF AN SMALL SIZE AXIAL AIR TURBINE)

  • 박수영;백제현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.567-571
    • /
    • 2011
  • Air Starter motors are used for the start of medium-speed diesel engine. One of the main part of air starting motors is the axial turbine stage. In this study, design of 1-stage axial type turbine for 14kw class air starter motors has been performed. The turbine blade was designed based on mean-line analysis. 1-D design calculation and numerical analysis with CFD were conducted iteratively. The validation between 1-D design method and numerical analysis for axial clearance has been performed. It revealed that there is optimum axial clearance of turbine design.

  • PDF