• 제목/요약/키워드: Axial cyclone

검색결과 25건 처리시간 0.031초

공기조화기 장착용 축상유입식 싸이클론의 압력손실에 대한 수치해석 및 실험적 연구 (Numerical and experimental study on the pressure dorp of axial-flow cyclone in the air handling unit)

  • 권순박;박덕신;조영민;김세영;김명준;김호중;김태성
    • 한국입자에어로졸학회지
    • /
    • 제5권2호
    • /
    • pp.37-43
    • /
    • 2009
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator are used in the air handling unit (AHU) of subway stations. However, those systems are prone to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts might malfunction due to the high load of particulates unless the filter medium is periodically replaced. In this study, the use of axial-flow cyclone was proposed for particulate filter unit in the AHU for its low operation and maintenance cost. Novel shape of axial-flow cyclone was designed by using computational fluid dynamics (CFD). The shape of vortex vane was optimized in terms of pressure drop and tangential velocity. In addition, CFD analysis was validated experimentally through the pressure drop measurement of mock-up model. We found that pressure drop and tangential velocity of fluid through the axia-flow cyclone was significantly affected by the rotating degree of vortex vane and the numerical prediction of pressure drop agreed well with experimental measurement.

  • PDF

디젤 엔진용 싸이클론 내부 수치 해석 (A Numerical Study on Axial Inlet Cyclone for Diesel Engine)

  • 김성광;손창석;김인관
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.16-21
    • /
    • 2006
  • On this study, numerical analysis was performed for the 3 dimensional flow field of gas and particle phase for axial inlet cyclone, a part of dust collector. We applied FVM to visualize the gas phase. The flow was solved using ${\kappa}-{\varepsilon}$ turbulence model. The major parameters considered in this study were helical guide vane, inner diameter, length. Particle trajectory calculations were performed for the particle sizes of $5{\mu}m{\sim}75{\mu}m$. The distribution curve of particle sizes was made of Rosin-Rammler function. The simulation results show various gas flows, particle trajectories on numerical models.

  • PDF

마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구 (Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor)

  • 오창보;최병일;한용식;김명배;황철홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1900-1905
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

  • PDF

마이크로 사이클론 연소기의 화염 안정화 기구 (Flame Stabilization Mechanism of a Micro Cyclone Combustor)

  • 오창보;최병일;한용식;김명배;황철홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2007년도 제34회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.139-144
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a component of mobile power generator (MPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately to prevent a flash-back. The flame shape stabilized inside the micro cyclone combustor was visualized experimentally and the flow field and the combustion characteristics of the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the overall flow and flame features of the combustor. The flame stabilization mechanism could be well understood using the velocity distribution inside the combustor. For only non-reacting case, it was found that a weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. It was also found that small regions that have a negative axial velocity exist near the fuel injection ports for both of non-reacting and reacting case. It was identify that a flame front was stabilized at the negative axial velocity regions near the fuel injection ports.

  • PDF

마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구 (Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor)

  • 최병일;한용식;김명배;황철홍;오창보
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.1042-1047
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio ($\Phi$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$<1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

하이브리드 사이클론 제트 연소기의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of a Hybrid Cyclone Jet Combustor)

  • 정원석;황철홍;이규영;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.149-155
    • /
    • 2002
  • A promising new approach to achieve low pollutants emission and improvement of flame stabilities is tested experimentally using a hybrid cyclone jet combustor employing both premixed and diffusion combustion mode, Three kind of nozzles are used for LNG(Liquified Natural Gas) as a fuel. The combustor is operated by two method, One is ATI(Air Tangential Injection) mode, generated swirl flow by air as general swirl combustor, and the other is PTI(Premixed gas Tangential Injection) mode, The PTI mode consists of diffusion flame of axial direction and premixed cyclone flame of tangential direction in order to stabilized the diffusion flame. The results showed that the stable region of the PTI mode is more larger than the ATI mode. In addition, the reduction of NOx emission in PTI mode, as compared with that for the ATI mode is at least 50% in stable region. Also, even using the low calorific fuel as $CO_2$-blended gas, the cyclone jet combustor has high performance of flame stability.

  • PDF

출구형상에 따른 축상유입식 싸이클론의 입자제거효율 (Particle Collection Efficiency of Axial- flow Cyclone with Outlet Shape)

  • 권순박;김세영;김명준;박덕신;정우태;김태성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.128-131
    • /
    • 2011
  • Management of indoor air quality of underground subway station is an important issue. The air handling unit (AHU) installed in the underground subway station is the main facility determining the air quality of station. Especially for removing particulate matters, it is important to operate the appropriate air filter. In this study, we studied particle collection efficiency of axail-flow cyclone for subway AHU. The particle collection efficiencies of axial-flow cyclones with three different outlet shape have been evaluated.

  • PDF

바이오 가스 소각용 저공해 사이클론 소각기 개발을 위한 수치 해석적 연구 (Numerical Study for the Design of Biogas-fired Low Emission Cyclone Incinerator)

  • 전영남;김시욱;백원석
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.401-410
    • /
    • 2002
  • Concerns for energy conservation, environmental pollution, and the fact that organic wastes account for a major portion of our waste materials, have created the interest of biogas, which usually contains about 60 to 70 percent methane, 30 to 40 percent carbon dioxide, and other gases, including ammonia, hydrogen sulfide, mercaptans and other noxious gases. Cyclone combustors are used for homing a wide range of fuels such as low calorific value gas, waste water, sludge. coal, etc. The 3-dimensional swirling flow, combustion and emission in a tangential inlet cyclone incinerator under different inlet conditions are simulated using a standard k-s turbulence model and ESCRS (Extended Simple Chemically-Reacting System) model. The commercial code Phoenics Ver.3.4 was used for the present work. The main parameters considered in this work are inlet velocity and air to fuel ratio. The results showed that the change of operating conditions had an influence on the shape and size of recirculation zones, mixture fraction and axial velocity which are important factors for combustion efficiency and emission behavior. The application of this kind of computer program seams to be promising as a potential tool for the optimum design of a cyclone combustor with low emission.

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.