• 제목/요약/키워드: Axial Tension

검색결과 301건 처리시간 0.024초

특별직교이방성 이론에 의한 포스트 텐션된 교량의 해석(II) - 강 판형교 - (Analysis of Post-tensioned Bridge by Specially Orthotropic Laminate Theory (II) - Steel Plate Girder Bridge)

  • 김덕현;원치문;이정호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.141-146
    • /
    • 2001
  • A post-tensioned steel plate girder bridge with cross-beams is analyzed by specially orthotropic laminate theory. The cross-sections of both girders and cross-beams are WF types. The result is compared with that of the beam theory. This bridge with simple support is under uniformly distributed vertical load, and axial loads and moment due to post-tension. In this paper, finite difference method for numerical analysis of simple supported bridge is developed. Relatively exact solution is obtained even with small number of meshes. Theory and analysis method of specially orthotropic laminate plates used in this paper can be used in design of new bridges, and maintenance and repair of old bridges.

  • PDF

단일 및 혼합모드 하중하에서의 레일강의 파괴조건 및 피로균열진전거동 (Fracture Criterion and Fatigue Crack Growth Behavior of Rail Steel Under Mode I & Mixed Mode Loading)

  • 김정규;이종선;김철수
    • 대한기계학회논문집A
    • /
    • 제23권6호
    • /
    • pp.1039-1047
    • /
    • 1999
  • It is necessary to evaluate the fatigue behavior of rail steel under the multi-axial stress state to assure the railway vehicle's safety. For this purpose, the stress analysis to investigate the crack initiation criteria, static failure and fatigue behavior under mixed-mode are performed. The stress analysis results show that the initiation of the transverse fissure depends on the maximum shear stress below the surface. For the mixed mode, the fatigue crack growth behavior which is represented by the projection crack length and comparative S.I.F, ${\Delta}K_v$, shows the more conservative results. Also, its rate is lower than that of the case of the mode I, and this difference decreases with increasing the stress ratio, R.

Flow Behavior of Safranine Solution in Prunus sargentii Rehder

  • Hong, Seong-Du;Ahmed, Sheikh Ali;Chun, Su-Kyoung
    • 한국가구학회지
    • /
    • 제18권4호
    • /
    • pp.282-286
    • /
    • 2007
  • An experiment was conducted to compare the 1% safranine solution flow depth in radial and longitudinal direction of Prunus sargentii. Longitudinal flow of safranine solution was found higher than radial flow. Body ray parenchyma was found more permeable than marginal ray parenchyma and it was about 1.3 times higher. Intercellular space conducted safranine solution more than ray parenchyma. Vessel was found to be the main avenue for liquid conduction in longitudinal direction. Different anatomical features of ray, vessel and fiber affected the penetration depth of safranine solution. Moreover initial penetration depth was found to be high and thereafter decreased gradually.

  • PDF

Essential Oil Penetration Depth in Prunus sargentii Rehder

  • Ahmed, Sheikh Ali;Hong, Seong-Du;Chun, Su-Kyoung
    • 한국가구학회지
    • /
    • 제18권4호
    • /
    • pp.307-311
    • /
    • 2007
  • An experiment was conducted to know the essential oil penetration depth in radial and longitudinal direction of Prunus sargentii. Oil penetration depth was found greater than radial flow depth. Vessel conducted oil more than wood fiber. In radial direction, body ray parenchyma was found more permeable than marginal ray parenchyma and it was about 138% times higher. Furthermore penetration depth of oil in intercellular space was greater than ray parenchyma and it was about 250% higher than ray parenchymas. Initial flow speed was found high and then it gradually decreased.

  • PDF

단부구속 효과에 따른 철근콘크리트 T형 벽체의 구조성능 평가에 관한 실험적 연구 (Experimental Study of Structural Capacity Evaluation of RC T-shape Walls with the Confinement Effect)

  • 하상수;윤현도;최창식;오영훈;이원호;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.191-196
    • /
    • 2001
  • The structural performance of a shear wall subjected to lateral loads is influenced by many factors, such as sectional shape, aspect ratio, vertical and horizontal reinforcement, lateral confinement and axial compression, etc. This experimental research is focusing to investigate the structural performance of T-shaped walls with different confining reinforcement. Experimental results show that all specimens finally failed by the crushing of the concrete in the compression zone. Although the location and content of the lateral confinement is different, the results are very similar during the negative loading direction where the flange is compressed. However, when flange is subjected to tension, the location and content of the lateral confinement results in a large difference in the structural performance of T-shaped walls. Therefore, selection of location and content of the lateral confinement would be important aspect in the design of the nonsymmetric structural walls.

  • PDF

Beam-column behavior of concrete filled steel tubes

  • Campione, G.;Scibilia, N.
    • Steel and Composite Structures
    • /
    • 제2권4호
    • /
    • pp.259-276
    • /
    • 2002
  • In the present investigation the experimental and theoretical flexural and compressive behavior of short tubular steel columns filled with plain concrete and fiber-reinforced concrete (FRC) was examined. For a given length of the members, the effects of different geometry and dimensions of the transverse cross-section (square and circular) were investigated. Constituent materials were characterized through direct tensile tests on steel coupons and through compressive and split tension tests on concrete cylinders. Load-axial shortening and load-deflection curves were recorded for unfilled and composite members. Finally, simplified expressions for the calculus of the load-deflection curves based on the cross-section analysis were given and the ultimate load of short columns was predicted.

포스트텐션 조립식 교각의 유효프리스트레스 크기 결정 (Determination of Effective Prestress of Post-tensioned Precast Bridge Piers)

  • 심창수;코엠찬다라
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.135-143
    • /
    • 2016
  • In this paper, a design concept of post-tensioned precast bridge piers was proposed to improve seismic behavior of the bridge pier. Mild reinforcing bars are placed continuously along the height of the column. Prestressing tendons are also provided to obtain re-centering capability for seismic events. Arrangement of the axial steels to prevent buckling of rebars at plastic hinge region was suggested and enhanced seismic performance was verified by experiments. Moment-curvature analyses were performed to evaluate the effect of effective prestress on seismic behavior after verifying the calculation method by cyclic tests of the precast columns. A real bridge pier was designed to investigate the seismic performance according to different level of effective prestress. Level of effective prestress showed obvious effect on crushing displacement but negligible effect on lateral displacement at fracture of tendons and reinforcements.

Inelastic distortional buckling of hot-rolled I-section beam-columns

  • Lee, Dong-Sik
    • Steel and Composite Structures
    • /
    • 제4권1호
    • /
    • pp.23-36
    • /
    • 2004
  • The inelastic lateral-distortional buckling of doubly-symmetric hot-rolled I-section beam-columns subjected to a concentric axial force and uniform bending with elastic restraint which produce single curvature is investigated in this paper. The numerical model adopted in this paper is an energy-based method which leads to the incremental and iterative solution of a fourth-order eigenproblem, with very rapid solutions being obtained. The elastic restraint considered in this paper is full restraint against translation, but torsional restraint is permitted at the tension flange. Hitherto, a numerical method to analyse the elastic and inelastic lateral-distortional buckling of restrained or unrestrained beam-columns is unavailable. The prediction of the inelastic lateral-distortional buckling load obtained in this study is compared with the inelastic lateral-distortional buckling of restrained beams and the inelastic lateral-torsional buckling solution, by suppressing the out-of-plane web distortion, is published elsewhere and they agree reasonable well. The method is then extended to the lateral-distortional buckling of continuously restrained doubly symmetric I-sections to illustrate the effect of web distortion.

스트럿-타이 모델을 이용한 세장한 철근콘크리트 부재의 강도평가 (Evaluation of Shear Strength of RC Beams using Strut-and-Tie Model)

  • 박홍근;엄태성;박종철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.271-274
    • /
    • 2005
  • Existing strut-and-tie model cannot be applied to analysis of slender beams without shear reinforcement because shear transfer mechanism is not formed. In the present study, a new strut-and-tie model with rigid joint was developed. Basically, concrete strut is modeled as a frame element which can transfer shear force (or moment) as well as axial force. Employing Rankine failure criterion, failure strength due to shear-tension and shear-compression developed in compressive concrete strut was defined. For verification, various test specimens were analyzed and the results were compared with tests. The proposed strut-and-tie model predicted shear strength and failure displacement with reasonable precision, addressing the design parameters such as shear reinforcement, concrete compressive strength, and shear span ratio.

  • PDF

형상비에 따른 비보강 조적벽체의 전단거동 평가에 관한 연구 (A Study on Evaluation of Shear Behavior of Unreinforced Masonry Wall with Different Aspect Ratio)

  • 이정한;강대언;양원직;우현수;권기혁;이원호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.46-49
    • /
    • 2006
  • In general, the shear behavior mode of URM wall expresses four types of modes such as rocking failure, sliding shear failure, toe crushing failure, and diagonal tension failure. From the comparison of each equation according to the shear behavior modes, the failure modes based on the aspect ratio and vertical axial stress can be expected. The objectives of this study is to find out the shear behavior of URM wall with different aspect ratio. The test results show that the aspect ratio is understood as an important variable.

  • PDF