• 제목/요약/키워드: Axial Gap

검색결과 252건 처리시간 0.032초

PIV를 이용한 초음파 진동에 의해 유도된 음향유동의 가시화 (Flow Visualization of Acoustic Streaming Induced by Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;권기정;이장연;이동렬
    • 한국소음진동공학회논문집
    • /
    • 제14권6호
    • /
    • pp.528-535
    • /
    • 2004
  • Ultrasonic Vibrator is designed to achieve the maximum vibration amplitude at 30 kHz by in-cluding a horn (diameter, 40 mm), mechanical vibration amplifier at the top of the ultrasonic vibrator in the system and making the complete system resonate. In addition, it is experimentally visualized by particle imaging velocimetry (PIV) that the acoustic streaming velocity in the gap is at maximum when the gap between the ultrasonic vibrator and stationary plate agrees with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave and the theoretical analysis of that is also accomplished and verified by experiment. It is observed that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary plate possibly changes due to the measurement of the average velocity fields of the acoustic streaming induced by the ultrasonic vibration at resonance and non-resonance. There exists extremely small average velocity at non-resonant gaps while the relatively large average velocity exists at resonant gaps compared with non-resonant gaps. It also reveals that there should be larger axial turbulent intensity at the hub region of the vibrator and at the edge of it in the resonant gap where the air streaming velocity is maximized and the flow phenomena is conspicuous than that at the other region. Because the variation of the acoustic streaming velocity at resonant gap is more distinctive than that at non-resonant gap, shear stress increases more in the resonant gap and is also maximized at the center region of the vibrator except the local position of center (r〓0). At the non-resonant gap there should be low values of vorticity distribution, but in contrast to the non-resonant gap, high and negative values of it exist at the center region of the vibrator with respect to the radial direction and in the vicinity of the middle region with respect to the axial direction. Acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover, the proposed method by acoustic streaming can be utilized to the nano and micro-electro mechanical systems as a driving mechanism in addition to the augmentation of the streaming velocity.

3차원 유한요소법을 이용한 축방향 자속형 브러시리스 DC 전동기 최적 설계 (Optimal Design of Axial Type Brushless DC Motor Using 3-D FEM)

  • 홍선기
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.143-147
    • /
    • 2005
  • 본 연구에서는 희토류 자석편을 이용한 이중 회전자를 갖는 축방향 자속형 브러시리스 DC 전동기를 설계한다. 이러한 종류의 전동기는 반경방향 자속형에 비해 축방향 길이가 짧고 조립이 용이한 장점이 있다. 충분한 토크를 얻기 위해서 NdFeB 자석이 이용되며 생산 비용을 고려하여 자석은 세그먼트로 만들어 진다. 이 전동기를 설계하기 위해 자기 등가회로 모델이 이용되었고, 정확한 파라미터를 얻기 위해 3차원 유한요소법을 이용하여 공극 자속밀도를 구하였다. 최적화된 설계 변수들은 유전 알고리즘을 이용하여 구하였다. 시뮬레이션결과로부터 자석에 따른 설계의 지침과 타당성을 확인하였다.

지하철 개착구 굴착시 주변자반과 구조물에 대한 거동예측과 실측의비교평가 (The Study on the Prediction and Measurement for the Behaviour of Structures and Weathered Soil & Rock in Excavating the Ventilation Shaft)

  • 김융태;안대영;김득기;한창헌
    • 터널과지하공간
    • /
    • 제4권1호
    • /
    • pp.63-76
    • /
    • 1994
  • This paper discusses contents of the existing design, the behaviours prediction on the strut and retaining wall around subsurfaces, and also evaluates the measured results in comparison with the management criterion during excavation period of ventilation shaft at Pusan-Subway 220. Field measurements showed that maximum displacement 23.74 mm at boundary site of multistratification and the weathered rock to be formed at 0.2~0.6 H of total excavating depth(H), 68 ton of maximum axial force and 4.4X102 kg/cm2 of stress on strut. The measured axial force exceeds prediction levels by up to 50 percent at the weathered soil & rock, and the others come under the category of their levels. The great gap of both field measurements and prediction on behaviour makes a difference of the site situation at the design stage and the practical working. This measured value is greatly safety in comparison with that of the safety criterion, but axial force at 4~5 strut of ventilation shaft l is higher than the prediction.

  • PDF

Estimation of Beam Mode Frequencies of Co-axial Cylinders Immersed in Fluid by Equivalent Mass Approach

  • Kim, Tae-Wan;Park, Suhn;Park, Keun-Bae
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.1-13
    • /
    • 2003
  • In this study, an effective method to estimate the fundamental frequencies of co-axial cylinders immersed in fluid is proposed. The proposed method makes use of the equivalent mass or density that is derived from the added mass matrix caused by the fluid-structure interaction (FSI) phenomenon. The equivalent mass is defined from the added mass matrix based on a 2-D potential flow theory. The theory on two co-axial cylinders extended to the case of three cylinders. To prove the validity of the proposed method, the eigenvalue analyses upon coaxial cylinders coupled with fluid gaps are peformed using the equivalent mass. The analyses results upon various fluid gap is conditions reveal that the present method could provide accurate frequencies and be suitable for expecting the fundamental frequencies of fluid coupled cylinders in beam mode vibration.

Design for Triple Band Patch Array Antenna with High Detection Ability

  • Kim, In-Hwan;Min, Kyeong-Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제13권4호
    • /
    • pp.214-223
    • /
    • 2013
  • This paper proposes a theoretical analysis of hidden device detection and a design of multiband circular polarization patch array antenna for non-linear junction detector system application. A good axial ratio of circular polarization patch antenna is realized by a new approach that employs inclined slots, two rectangular grooves and a truncated ground for the conventional antenna. A good axial ratio of the 1.5 dB lower is measured by having an asymmetric gap distance between the ground planes of the coplanar waveguide feeding structure. The common ground plane of the linear array has an optimum trapezoidal slot array to reduce the mutual coupling without increasing the distance between the radiators. The higher gain of about 1 dBi is realized by using the novel common ground structure. The measured return loss, gain, and axial ratio of the proposed single radiator, as well as the proposed array antennas, showed a good agreement with the simulated results.

종축 자속형 영구자석 동기 발전기의 전자기적 구조 변경에 따른 출력특성 비교 (The Comparison of Output Characteristic by the Electro-magnetic Structure Modification of the Axial Flux Type Permanent Magnet Synchronous Generator)

  • 정태욱;배병덕;김회천
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.42-48
    • /
    • 2011
  • Generally, the structure without the stator core Axial Field Permanent Magnet (AFPM) generator was simple and there was nearly no cogging toque. And because it had the wide driving rate area, it had been being mainly used in the small wind power generation system. However, AFPM generator with non-slotted stator can't generate high voltage at low wind speed due to long air-gap. It is the reason of output efficiency drop. Therefore, in this paper, the AFPM synchronous generator with internal rotor and dual slotted stators for the small wind turbine is studied, and deal with a cogging torque minimization through the determination of optimum pole-arc ratio.

Design and Analysis of Axial Flux Permanent Magnet Synchronous Machine

  • Jo, Won-Young;Lee, In-Jae;Cho, Yun-Hyun;Koo, Dae-Hyun;Chun, Yon-Do
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.61-67
    • /
    • 2007
  • In this article, a special kind of axial flux permanent magnet machine has proved to be suitable for high torque and low speed applications. An innovative design of the machine has been proposed in order to make the machine suitable for traction applications by means of field-weakening. The aim of this paper is to analyze, in general terms, the basic equations that describe the operating conditions of such machines. Optimal sizes for design can be obtained by calculating the power density and the air-gap flux density, etc.

A Fast Analytic Model of Axial Flux Permanent Magnet Machines with Static/Dynamic Axis Eccentricity

  • Guo, Baocheng;Huang, Yunkai
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.554-560
    • /
    • 2016
  • This paper presents a general analytical model to calculate the characteristics of axial-flux permanent-magnet machines with axis eccentricities. The radial and tangential magnetic flux densities in the air gap under normal conditions were first obtained using a combination of Maxwell's equations and Schwarz-Christoffel (SC) transformation. Next, equations for the radii were deduced to investigate the static/dynamic eccentricities. The back electromotive forces (EMFs) were calculated and compared with those obtained from finite element (FE) analysis. The analytical predictions show good agreement with the FE results. Detection approaches were obtained by comparing with normal conditions, and the analytical model was verified experimentally.

서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성 (Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods)

  • 조영범;정재헌;김희중
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.366-376
    • /
    • 2013
  • 구강내 스캔(Group 1), 모델 광학 스캔(Group 2)과 모델 접촉식 스캔(Group 3)방식으로 각각 zirconia 코핑을 제작하여 광학 현미경으로 적합성을 관찰하였다. 측정항목은 변연오차(absolute marginal discrepancy;AMD), 변연간극(marginal gap; MG), 측방간격(gap of axial wall; GA), 선각간격(gap of line angle; GL)와 교합간격(gap of occusal surface; GO)이었으며, 결과는 아래와 같았다. 1. Group 1, Group 2, Group 3의 평균 AMD는 각 각 $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$이고, Group1, Group 2, Group 3의 MG는 각 각 $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$였다. AMD와 MG는 각 그룹에서 통계학적으로 유의한 차이를 보여주지 않았다(Anova test, P>0.05). 2. Group 2의 GA가 Group 1과 Group 3에 비해 통계학적으로 유의하게 적은 수치를 나타내었다(Anova test, P<0.05). 3. Group 1의 GL과 GO가 다른 그룹에 비해 통계학적으로 높은 수치를 나타내었다(Mann-whitney test(P<0.05). 세 가지 스캔 방식으로 제작된 zirconia 코핑은 세라믹 보철의 가장 중요한 평가 요소인 AMD와 MG에서 서로 통계학적 차이를 보이지 않았다.