• 제목/요약/키워드: Axial

검색결과 8,463건 처리시간 0.029초

액체로켓엔진 터보펌프용 펌프의 축추력 조절에 관한 연구 (Study on the Control of the Axial Thrust of a Pump for Liquid Rocket Engine Turbopumps)

  • 최창호;노준구;김대진;김진한
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.36-40
    • /
    • 2012
  • The magnitude of the axial thrust acting on pump bearings has a great influence on the operational reliability and service life of a pump for turbopumps. In the present study, radial vanes are introduced to the pump casing to control the axial thrust by changing the cavity pressure between the impeller and the casing. To investigate the effect of the vanes on the axial thrust of the pump, experimental and computational studies were performed with and without the vanes. It is shown that the vanes reduce the cavity pressure by preventing the flow from rotating with the impeller. Experimental and computational results show similar trend for the axial thrust difference between two cases with and without the vanes. The results show that the cavity vanes are very effective in controlling the magnitude of the axial thrust.

탄소섬유쉬트로 횡구속된 콘크리트 공시체의 압축 거동에 관한 연구 (A Study on the Axial Behavior of the Concrete Cylinders Confined by Carbon Fiber Sheets)

  • 황진석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권4호
    • /
    • pp.141-148
    • /
    • 2000
  • Recently the Carbon Fiber Sheet(CFS) is widely used for strengthening damaged RC structures. Strengthening compression members such as column can increase ductility and strength due to the confinement effect. In this experiment, the behavior of concrete cylinders confined by CFS was examined. The confinement pressure is increased linearly as axial stress is increased in low axial stress, and the confinement effect of CFS was rapidly developed after near maximum axial stress, thus axial strength and ductility was improved. As the ratio of CPS is increased, concrete cylinders failed due to local fracture of CFS. The confinement effect of circular section is more efficient than that of rectangular section. And significant improvement of axial strength, axial strain, transverse strain at failure is observed in circular section. This is because in rectangular section the local fracture of CFS near corner may be occured, thus the strain efficiency ratio must be considered for RC structures with CFS.

  • PDF

Post-buckling behaviours of axially restrained steel columns in fire

  • Li, Guo-Qiang;Wang, Peijun;Hou, Hetao
    • Steel and Composite Structures
    • /
    • 제9권2호
    • /
    • pp.89-101
    • /
    • 2009
  • This paper presents a simplified model to study post-buckling behaviours of the axially restrained steel column at elevated temperatures in fire. The contribution of axial deformation to the curvature of column section is included in theoretical equations. The possible unloading at the convex side of the column when buckling occurs is considered in the stress-strain relationship of steel at elevated temperatures. Parameters that affect structural behaviours of the axial restrained column in fire are studied. The axial restraint cause an increase in the axial force before the column buckles; the buckling temperature of restrained columns will be lower than non-restrained steel columns. However, the axial force of a restrained column decreases after the column buckles with the elevation of temperatures, so make use of the post-buckling behaviour can increase the critical temperature of restrained columns. Columns with temperature gradient across the section will produce lower axial force at elevated temperatures.

Behaviour of flush end-plate beam-to-column joints under bending and axial force

  • da Silva, Luis Simoes;de Lima, Luciano R.O.;da S. Vellasco, Pedro C.G.;de Andrade, Sebastiao A.L.
    • Steel and Composite Structures
    • /
    • 제4권2호
    • /
    • pp.77-94
    • /
    • 2004
  • Steel beam-to-column joints are often subjected to a combination of bending and axial forces. The level of axial forces in the joint may be significant, typical of pitched-roof portal frames, sway frames or frames with incomplete floors. Current specifications for steel joints do not take into account the presence of axial forces (tension and/or compression) in the joints. A single empirical limitation of 10% of the beam's plastic axial capacity is the only enforced provision in Annex J of Eurocode 3. The objective of the present paper is to describe some experimental and numerical work carried out at the University of Coimbra to try to extend the philosophy of the component method to deal with the combined action bending moment and axial force.

탄소섬유쉬트로 횡보강된 R/C단주의 압축거동 (Axial Compressive Behavior of the R/C Short Columns Strengthened with CFS)

  • 신성우;반병열;이광수;안종문;황준호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권4호
    • /
    • pp.201-208
    • /
    • 1998
  • To observe the confinement effects of Carbon Fiber Sheet(CFS) on the high-strength R/C short columns, Fifteen specimens with CFS were manufactured and tested under uni-axial compressive load. Major variables of this study are amount, spacing, type of CFS and amount of transverse steel. Increasing the amount of transverse steel and CFS, compressive strength and axial rigidity is improved. R/C columns with transverse steel and CFS exhibited less axial stress than columns with only CFS. From the test results, it is shown that the area confined with transverse steel and CFS is considerably important to evaluate axial stress of R/C short columns.

  • PDF

테이프와 거칠기가 설치된 사각 채널의 압력강하 특성 (Characteristics of Pressure Drops in Square Channels with Twisted Tape Inserts plus Axial Interrupted Ribs)

  • 안수환;배성택;강호근
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.38-42
    • /
    • 2006
  • Pressure drops and friction factors in square channels with twisted tape inserts plus axial interrupted ribs are investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, $e/D_h$, is kept at 0.057 and test section length-to-hydraulic diameter, $L/D_h$ is 30. The pressure drops and friction factor values are enhanced with axial interrupted ribs and twisted tape inserts. Square channels with twisted tape inserts plus axial interrupted ribs show the greatest pressure loss penalty in the present work. Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Slope-Rotatability in Axial Directions for Second Order Response Surface Designs

  • Jang Dae-Heung
    • Communications for Statistical Applications and Methods
    • /
    • 제12권1호
    • /
    • pp.253-264
    • /
    • 2005
  • Hader and Park(l978) suggested the concept of slope-rotatability in axial directions for second order response surface designs. In this paper, the moment conditions for slope-rotatability in axial directions are shown and the measures for evaluating slope-rotatability in axial directions are proposed.

종진동에 의한 크랭크축의 안전성 평가 (Security Evaluation of Crankshaft due to Axial Vibration)

  • 이돈출;윤완배;유정대
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.139-145
    • /
    • 1997
  • Nowadays, the axial stiffness of crankshaft of long-stroke diesel engine is low compared to that of the old types of engine by increasing stroke/bore ratio and major critical speed might occur within engine operation speed. An axial damper needs to be installed in order to reduce the axial vibration of the crankshaft in the event of reduced or stopped axial damper function are discussed.

  • PDF

소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가 (Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT)

  • 박기석;김동현
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.683-689
    • /
    • 2019
  • 소아의 선천적 심장질환 진단을 위해 High Pitch Mode를 사용하여 획득한 소아 심장 CT 영상과 Wide Coverage Volume Axial Mode를 사용하여 획득한 소아 심장 CT 영상으로부터 환자의 피폭선량과 각 영상의 화질을 비교 및 분석하여 Wide Coverage Volume Axial Mode의 유용성을 평가해보고자 한다. 소아 심장 CT 검사 시 High Pitch Mode와 Wide Coverage Volume Axial Mode를 각각 50명 총 100명의 환자를 대상으로 시행하였으며, 각 프로토콜로부터 얻은 영상을 이용하여 환자의 피폭선량을 비교하였다. 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상의 화질을 비교하였다. High Pitch Mode에 비해 Wide Coverage Volume Axial Mode를 사용하여 검사하였을 때 환자의 피폭선량이 13.07% 감소하였고, SNR과 CNR이 향상되었다. Wide Coverage Volume Axial Mode는 고속 회전 스캐너를 이용하여 조사시간을 줄이고, 저선량 기술인 ASi R-V를 통해 High Pitch Mode를 사용했을 때보다 환자의 피폭선량이 감소하고 영상의 화질 또한 향상되는 유용한 검사라 할 수 있다.

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.