• 제목/요약/키워드: Average turbidity

검색결과 141건 처리시간 0.025초

액상소석회와 이산화탄소를 이용한 수돗물 부식성 개선 (Improvement of tap water corrosivity by lime and carbon dioxide)

  • 김진근;이정훈
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.725-733
    • /
    • 2014
  • 16 water treatment plants(WTPs) in Jeju province were investigated to evaluate the corrosivity of tap water. In addition, the impacts of lime and carbon dioxide on LI changes at ES WTP were analyzed. The average of LI in Jeju tap was -1.78 which was similar to that of in-land multi-regional WTPs. The recommended process to improve LI of ES WTP which has high corrosivity(i.e., LI = -2.61) was to combine lime and carbon dioxide with the dosages of 20 mg/L and 5 mg/L respectively to meet LI of -1.0 ~ 0. pH was confirmed to be a major water quality parameter that determined LI based on the correlation results among LI and water quality parameters. Precaution on turbidity increase by lime addition should given to minimize particle breakthrough in the distribution system. Turbidity increase can be controlled by the addition of lime prior to filters.

경기지역 목장수의 위생화학적 조사연구 (Hygienic Chemical Conditions of Farm Waters in Kyunggi Province)

  • 박석기;윤중섭;김은정;임봉택;이용욱
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.22-28
    • /
    • 1993
  • In order to investigate the hygienic chemical conditions of farm waters used as the potable and cleaning water for cow, we examined the pH, turbidity, KMnO$_4$ consumption, total hardness, chlorine, sulfate, NH$_3$-N, NO$_3$-N, lead, maganese, copper, zinc, fluoride and chrome for 78 farm waters around Kyunggi Province. Of 78 farm waters tested, average pH was 6.70+_0.06, turbidity 0.724 $\pm$ 0.081, KMnO$_4$ consumption 4.200 $\pm$ 0.256 mg/l, total hardness 107.46 $\pm$ 6.90 mg/l, NH$_3$-N 0.043 $\pm$ 0.037 mg/l, NO$_3$-N 8.096 $\pm$ 0.652 mg/l, chlorine 21.414 $\pm$ 2.187 mg/l, sulfate 12.737 $\pm$ 1.511 mg/l, lead 0.076 $\pm$ 0.001 mg/l, manganese 0.029 $\pm$ 0.004 mg/l, copper 0.018 $\pm$ 0.002 mg/l, zinc 0.055 $\pm$ 0.005 mg/l, chrome 0.048 $\pm$ 0.002 mg/l and fluorine 0.011 $\pm$ 0.001 mg/l. According to the geological characteristics, the concentrations of total hardness, NO$_3$-N, pH and chlorine in farm waters of Hwasung gun were higher than those in Yangpyung and Kwangju gun. In hygienic chemical items tested, there were high significanc among NO$_3$-N, total hardness, sulfate and chlorine. KMnO$_4$ consumption was significant with NH$_3$-N, sulfate and pH. But in heavy metals, there were significance between lead and copper, copper and chrome, and copper and fluorine.

  • PDF

낙동강 하류 갈전지역에서의 강변여과수 수질평가 (Evaluation of Bank Filtrate Water Quality in Galjon, the Downstream of the Nakdong River)

  • 이수영;정태학
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.487-494
    • /
    • 2003
  • In this research, water qualities of river water and bank-filtrate were compared for six months including winter season. The location studied was Galjon area, the downstream of the Nakdong river. The well for bank-filtrate was installed 40 m apart from riverside. Main analytic results of bank-filtrate and river water were summarized as followings; the average concentrations in bank-filtrate were turbidity 0.8NTU, TN 0.4mg/l, $BOD_5$, 0.1mg/l, $KMnO_4$ consumption 1.6mg/l, heterotrophic bacteria 350cfu/ml, Fe 0.5mg/l, Mn 0.99mg/l while the average concentrations in river water were turbidity 6.1NTU, TN 3.9mg/l, $BOD_5$, 3.6mg/l, $KMnO_4$ consumption 11mg/l, heterotrophic bacteria 1,640cfu/ml, Fe 0.28mg/l, Mn 0.04mg/l. Water quality of bank-filtrate was mostly shown a good results than it of river water excepting Fe and Mn. In even basic constituents such as water temperature and pH, bank-filtrate was very settled while river water was extraordinary changable and high. In case of nitrogen, especially, total nitrogen of river water was 3.9mg/l while it of bank-filtrate was 0.4mg/l and its reduction was very high. The reason is that $NH^+_4-N$ among total nitrogen in the river water is nitrified and then denitrified in soil layer when it is pumped up as bank-filtrate. But Fe and Mn caused by the characteristics of soil was very high in bank-filtrate while Mn in river water was particularly very low and settled. As the distance between riverside and well was longer, concentration of Fe and Mn may be went up while its bacteria may be reduced.

수도시설 운영정보화 시스템 구축 및 효율개선효과 (Constructing the Operating Information System(OIS) and Improving the Water Quality by OIS in Water Treatment Plants)

  • 오정우;송윤섭;강금배;유만식
    • 대한환경공학회지
    • /
    • 제29권6호
    • /
    • pp.699-705
    • /
    • 2007
  • 본 연구에서는, 안산정수장에 구축된 수도시설 운영정보화 시스템에 의한 처리수질개선 등 정수장 효율개선효과를 평가하였다. 분석기간 동안의 안산정수장 생활용수 유입유량은 운영정보화 시스템이 구축되기 전인 2004년도보다 구축 후인 2005년도가 약 15.6% 감소한 것으로 나타났다. 원수의 평균탁도는 2005년 12.37 NTU, 2004년 12.06 NTU로 비슷한 값을 나타내었으나, 연평균 응집제의 주입농도는 2005년도가 12.06 mg/L으로 2004년(10.31 mg/L)보다 다소 높은 것으로 나타났고, 정수탁도는 약간 개선된 처리효율을 나타내었다. 원수의 $COD_{Mn}$ 및 BOD 등의 분석결과, 2004년보다 2005년의 원수수질이 개선된 것으로 판단할 수 있었다. 정수의 $KMnO_4$ 소비량은 2004년(2.95 mg/L)보다 2005년은 1.25 mg/L로써 그 양이 줄어들었고, THMs의 농도도 2004년(0.038 mg/L)보다 2005년 0.025 mg/L로써 다소 개선되었다. 본 연구결과, 약품주입 등 정수장 운영은 운영 정보화 시스템의 구축에 의해 보다 최적의 상태를 도모할 수 있으며, 이에 따라 수질개선효과도 있음을 판단할 수 있었다.

로프형 미생물 담체 침전조를 이용한 상수원수중의 NOM 제거 (Removal of NOM Using Biological Rope Media Sedimentation Tank)

  • 심상준;강연석;김우식;박대원
    • KSBB Journal
    • /
    • 제16권4호
    • /
    • pp.332-336
    • /
    • 2001
  • 본 연구에서는 정수처리 중에서 BAC(Biological activated carbon) 처리의 생물분해능과 같이 NOM의 생분해성 부분을 제거하고자 로프형 미생물 담체를 침전조에 적용하는 공정을 시도하였다. 다양한 운전조건을 적용하여 DOC와 UV$_{254}$ 그리고, 탁도 제거효과를 평가하였는데, 담체 설치는 일반적인 정수처리 공정을 모사한 pilot plant에 첫 번째로 아무 전 처리도 거치지 않은 팔당원수를 바로 지나도록 하였고(Media 1), 두 번째는 팔당원수를 오존으로만 전처리한 후 지나도록 하였으며(Media 2), 세 번째는 전 오존과 응집-침전과정이 끝난 후 지나도록 하였다(Media 3). 원수의 DOC 농도는 1.3~3.4 mg/L이고, UV$_{254}$는 0.027~0.039 ($cm^{-1}$ /)이며, 탁도는 0.3~4.5 NTU 였다. 평균 DOC 농도는 media 1, 2, 3에서 각각 2.2 mg/L, 1.8 mg/L, 1.3 mg/L를 보였다. 반면에 침전조에서는 1.5 mg/L의 농도를 보여 media 3에서 가장 높은 제거량을 나타내었다. 평균 UV$_{254}$ 값은 media 1, 2, 3에서 각각 0.037 ($cm^{-1}$ /), 0.027 ($cm^{-1}$ /), 0.014 ($cm^{-1}$ /)를 나타내었으며, 침전조에서의 UV$_{254}$ 값은 media 3와 비슷한 0.014 ($cm^{-1}$ /)를 보였다. 평균 탁도는 media 1, 2, 3에서 각각 1.1 NTU, 0.9 NTU, 0.5 NTU를 나타내었다. 위의 결과를 보면 로프형 미생물 담체 침전조는 일반적인 침전 공정에 바로 적용할 수 있는 경제적인 장치로 활용 가능할 것이다.

  • PDF

반응표면 분석을 이용한 사과.당근 혼합주스의 청징공정 최적화 (Use of Response Surface Methodology for Optimization of Clarified Mixed Apple and Carrot Juice Production)

  • 석은주;이준호
    • 한국식품영양과학회지
    • /
    • 제35권8호
    • /
    • pp.1051-1056
    • /
    • 2006
  • 온도와 ATP 증가에 따라 사과.당근 배합비율과 상관없이 혼합주스의 투과플럭스가 비례적으로 증가했으며, 특히 온도변화에 따른 투과플럭스의 증가가 뚜렷했다. 사과와 당근비가 3:1인 실험구에서 가용성 고형분과 총당의 함량이 높게 측정되었고, 가용성 고형분의 경우 시료배합비율의 영향이, 총당의 경우 온도의 영향이 큰 것으로 나타났다. 시료배합비율에 따른 비타민 C 함량차이는 크지 않았으나 당근의 함량이 많을수록 비타민 C의 함량이 높게 측정되었고, 압력증가에 따른 비타민 C 함량 증가가 뚜렷했다. 사과의 함량이 높을수록 산도도 높았고, 온도증가에 따른 산도의 증가도 뚜렷했다. 한외여과 결과, 전 시료에 걸쳐 우수한 청징효과를 나타내었고, 사과와 당근비가 3:1인 실험구에서 그 청징효과가 두드러졌으며, 또한 점도변화도 가장 컸다. 또한 공정최적화 결과 공정온도 및 ATP가 각각 $44.97^{\circ}C$, 113.57 kPa이고 사과의 혼합비율이 28.50%인 경우 $flux=0.216\;L/m^2.h$, soluble $solids=10.39^{\circ}Brix$, total sugar=71.32 mg/mL, vitamin C=315.18 mg%, acidity=7.78 mL, turbidity=0.017, viscosity=1.44 cp인 사과.당근 혼합과채주스를 제조할 수 있는 것으로 나타났다.

가정용 정수기의 수질에 대한 위생학적 조사 소견 (A Sanitary Survey on the Clean Water by Domestic Purifier)

  • 채용곤
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

서울시 지하수 수질특성에 관한 연구 (The characteristics of the Groundwater Quality in Seoul)

  • 김익수;엄석원;이재영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.225-228
    • /
    • 2003
  • For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. 1. The rates of groundwater for drinking water were 10.5% in Yangcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1%(786 wells) for civil defense emergency, 22.1%(299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. 2. The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for tither uses-domestic, industrial, agricultural uses- were shown to be proper. 3. For drinking water, the average values of colar, turbidity, NH3-N, F, and Fe were 11.216 degree, 2.138 NTU, 2.458mg/l, 0.212mg/1 and 0.507mg/1 respectively. 4. In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO$_3$-N(-0.171) and F ̄(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.

  • PDF

국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로) (Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998))

  • 윤제용;조순행;김해심
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF

천연조류제거제를 활용한 응집·부상 전처리공정의 기존 응집공정 대체 가능성 (Substitutability of coagulation process by pre-treatment of coagulation·flotation using natural algae coagulant)

  • 장여주;정진홍;임현만;장향연;김원재
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.39-50
    • /
    • 2017
  • In the coagulation/sedimentation (C/S) process of the water treatment process, the inflow of massive algal bloom causes many problems including fouling of filter media. This study was conducted to find out the way to remove the algae's harmful effects by addition of pre-treatment prior to C/S process. Many Jar-tests were conducted such as (1) ACF (Algae Coagulation Flotation) process using natural algae coagulant (Water $Health^{(R)}$), (2) ACF + C/S process and (3) C/S process with a variety of conditions using cultured algae. The average values of turbidity were (1) 0.42 NTU for ACF process, (2) 0.13 NTU for ACF + C/S process and (3) 0.25 NTU for C/S process. It was shown that the treatment efficiency of ACF process could get low turbidity results, and ACF + C/S process could achieve more efficient results than those of C/S process. Any negative effects of ACF process to the efficiency of C/S process were not observed in ACF + C/S process. In order to reduce the unfavorable effects of algae, it was found out that the introduction of ACF process in the forms of (1) ACF or (2) ACF + C/S could be one of the effective and alternative solutions.