THE FACTORS WHICH AFFECT THE EXTERNAL RADIATION DOSE RATE OF PET-CT PATIENTS

  • Cho, Ihn Ho;Kim, Su Jin;Han, Eun Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.231-236
    • /
    • 2012
  • This study derived measures to reduce exposure doses by identifying factors which affect the external radiation dose rate of patients treated with radiopharmaceuticals for PET-CT tests. The external radiation dose rates were measured on three parts of head, thorax and abdomen at a distance of 50cm from the surface of 60 PET-CT patients. It showed there are changes in factors affecting the external radiation dose rate over time after the administration of F-18 FDG. The external radiation dose rate was lower in the patients with more water intake than those with less water intake before the injection of radiopharmaceuticals at all three points: right after the injection of radiopharmaceuticals (average 4.17 mins), after the pre-PEET-CT urination step (average 77.47 mins), and right after the PET-CT test (average 114.15 mins). The study also found there is a need to increase the amount of water intake before the injection of radiopharmaceuticals in order to maintain a low external radiation dose rate in patients. This strategy is only possible under the assumption that the quality of the video has not changed after conducting this study on the relations between the image and quality. This study also found a need to use radiopharmaceuticals with the minimum amount needed for each patient because F-FDG doses affects the external radiation dose rate at the point right after the injection of radiopharmaceuticals. Urination frequency was the most significant factor to affect the external radiation dose rates at the point right after the PET-CT test and the point after the pre-PET-CT urination step. There is a need to realize the strategy to increase the urination frequency of patients to maintain the external radiation dose rate low (average 77.47 mins) before and after the injection of radiopharmaceuticals. In addition, at this point, there is a need to take advantage of personal strategies because the external radiation dose rate is lower if the fasting time is shorter, the contrast medium is used, and the amount of water intake is increased after the administration of radiopharmaceuticals. Finally this study found the need to be able to generalize these findings through an in-depth research on the factors affecting the external radiation dose rate, which includes radiopharmaceutical dose, urination frequency, the amount of water intake, fasting time and the use of contrast medium.

Evaluations and Comparisons of Body Surface Doses during Breast Cancer Treatment by Tomotherapy and LINAC Radiotherapy Devices

  • Lee, Hyun-Jik;Bae, Sun-Hyun;Cho, Kwang Hwan;Jeong, Jae-Hong;Kwon, Su-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.218-225
    • /
    • 2017
  • Effects on skin caused by the dose from linear accelerator (LINAC) opposing portal irradiation and TomoDirect 3-D modeling treatment according to the radiation devices and treatment methods were measured, and a comparative analysis was performed. Two groups of 10 patients each were created and measurements were carried out using an optically stimulated luminescence dosimeter. These patients were already receiving radiation treatment in the hospital. Using the SPSS statistical program, the minimum and maximum average standard deviations of the measured skin dose data were obtained. Two types of treatment method were selected as independent variables; the measured points and total average were the dependent variables. An independent sample T-test was used, and it was checked whether there was a significance probability between the two groups. The average of the measured results for the LINAC opposing portal radiation was 117.7 cGy and PDD 65.39% for the inner breast, 144.7 cGy and PDD 80.39% for the outer breast, 143.2 cGy and PDD 79.56% for the upper breast, 151.4 cGy and PDD 84.11% for the lower breast, 149.6 cGy and PDD 83.11% for the axilla, and 141.32 cGy and PDD 78.51% for the total average. In contrast, for TomoDirect 3-D conformal radiotherapy, the corresponding measurement values were 137.6 cGy and PDD 76.44%, 152.3 cGy and PDD 84.61%, 148.6 cGy and PDD 82.56%, 159.7 cGy and PDD 88.72%, and 148.6 cGy PDD 82.56%, respectively, and the total average was 149.36 cGy and PDD 82.98%. To determine if the difference between the total averages was statistically significant, the independent sample T-test of the SPSS statistical program was used, which indicated that the P-value was P=0.024, which was 0.05 lower than the significance level. Thus, it can be understood that the null hypothesis can be dismissed, and that there was a difference in the averages. In conclusion, even though the treatment dose was similar, there could be a difference in the dose entering the body surface from the radiation treatment plan; however, depending on the properties of the treatment devices, there is a difference in the dose affecting the body surface. Thus, the absorbed dose entering the body surface can be high. During breast cancer radiotherapy, radiation dermatitis occurs in almost all patients. Most patients have a difficult time while undergoing treatment, and therefore, when choosing a radiotherapy treatment method, minimizing radiation dermatitis is an important consideration.

Geometric Evaluation of Patient-Specific 3D Bolus from 3D Printed Mold and Casting Method for Radiation Therapy

  • An, Hyun Joon;Kim, Myeong Soo;Kim, Jiseong;Son, Jaeman;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.32-38
    • /
    • 2019
  • Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

Effect of a Finite Substrate on the Radiation Characteristics of a Linear Phased Array Antenna Positioned along the E-plane (유한한 기판 크기가 E-평면으로 배열된 선형 위상 배열 안테나의 방사 특성에 미치는 영향)

  • Kim, Tae-Young;Kim, Gun-Su;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.46-53
    • /
    • 2011
  • The effect of a finite substrate on the radiation characteristics of a linear 7-element array antenna positioned along the E-plane is investigated. Active reflection coefficients and average active element patterns are simulated for various substrate sizes. The E-plane radiation pattern of a fully excited array for various scan angles is correlated with the active reflection coefficient and average acitive element pattern. The effect of E-plane substrate size on the radiation characteristics of a linear array along the E-plane is larger than that of H-plane substarte size.

A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital (일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석)

  • Yang, Nam-Hee;Chung, Woon-Kwan;Dong, Kyung-Rae;Choi, Eun-Jin;Ju, Yong-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

Shielding Effect of Radiation Protector for Interventional Procedure (중재적 방사선 분야 방호용구 차폐효과)

  • Ko, Shin-Kwan;Kang, Byung-Sam;Lim, Chung-Hwang
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.213-219
    • /
    • 2007
  • The purpose of this study is to evaluate shielding effect of radiation protector for interventional radiologists in procedures by measuring inside and outside of radiation protector. In this study, we measured the radiation dose of 4 interventional radiologists during TACE and PTBD procedure for 4 month(2005.05-2005.09). Absorbed dose were measured by TLD placed underneath and over radiation protector such as Goggle, Thyroid protector, Apron and placed on the 4th finger of Hand. In addition, we measured background radiation dose in the control room using TLD. During TACE procedure, using 0.07 mmPb Goggle decreased average 53.8% of radiation dose rate in continuous fluoroscopic mode and decreased average 77.6% of radiation dose rate in pulse fluoroscopic mode. Using 0.5 mmPb Thyroid protector decreased average 88.9% of radiation dose rate in continuous fluoroscopic mode and decreased average 92.8% in pulse fluoroscopic mode. During PTBD procedure, using 0.07 mmPb Goggle decreased radiation dose rate average 62.7%, 87.9% by 0.5 mmPb Thyroid protector, 90.5% by 0.5 mmPb Apron. The average fluoroscopic time of PTBD was 6.14 min. shorter than TACE procedure, but radiation exposure dose rate of PTBD was 3 times higher in total body dose, and 40 times higher in hand dose rate than TACE. Interventional radiologists must wear thicker protector recommended over 0.5 mmPb. Also, they must use lead Goggle during interventional procedure. Abdomen dose decreased average 38.4% by drawing a lead curtain under the patient's table, therefore, they must draw a lead curtain to shield scattering ray. Radiation exposure dose decreased average 59.0% by using pulse fluoroscopic mode. So radiologists would better use pulse fluoroscopic mode than continuous fluoroscopic mode to decrease exposure dose.

  • PDF

N-Nitrosodimethylamine Concentrations in Domestic and Imported Beer in Korea

  • Ahn, Hyun-Joo;Kim, Jae-Hyun;Cheorun Jo;Kim, Myung-Chul;Hong, Jin-Hwan;Byun, Myung-Woo
    • Preventive Nutrition and Food Science
    • /
    • v.7 no.2
    • /
    • pp.219-221
    • /
    • 2002
  • N-Nitrosodimethylamine (NDMA) was determined in both domestic Korean and imported beers, from the Netherlands, USA, Japan, Belgium and Germany. Among the 8 kinds of Korean beers, 4 were contaminated with NDMA, and 4 were not. The average concentration of NDMA detected in Korean beers was 0.78 $\mu\textrm{g}$/kg and the maximum NDMA concentration was 5.73 $\mu\textrm{g}$/kg. NDMA was only detected in one imported beer, which had a concentration of 5.29 $\mu\textrm{g}$/kg. Assuming an average concentration of 0.78 $\mu\textrm{g}$/kg NDMA in Korean domestic beer, the average daily intake of NDMA through domestic beer consumption by a typical Korean is approximately 0.58 $\mu\textrm{g}$/person/day.

STUDY ON ENTRANCE SKIN DOSE AT PANORAMIC RADIOGRAPHY IN INCHEON, KOREA

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong Kyoon
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.182-186
    • /
    • 2014
  • Recently, the use of panoramic radiography has shown a constant increase, and significant research is underway. However, radiation exposure attracts less attention in dental radiography than in other types of radiography. We used an OSLD for measurement of the entrance skin dose in eyeballs and the thyroid region, both of which are not covered by examinations but are included in radiographical regions and are sensitive to radiation, as well as orally in Incheon and reported the results. The entrance skin dose was 0.0282 mSv on average for the oral region, and 0.0259 mSv on average for the eyeball, and 0.0261mSv on average, for thyroid gland. While there is no proper shielding method for the eyeball, a thyroid protector is not used by most hospitals and most hospitals are equipped with an apron and a thyroid protector separately; thus, it is necessary to use an integration of an apron and a thyroid protector and medical device manufacturers need to develop a method for controlling the length of the slit in the slit-type area of radiation occurrence in order to reduce unnecessary exposure.

A Survey about Self-Efficacy and Consciousness on the Use of Radiation, Knowledge and Attitude for Student at Department of Dental Hygiene (부산지역 치위생과 학생의 자기효능감과 방사선 이용에 대한 의식도, 지식 및 태도에 관한 조사연구)

  • Jung, Young-Hee;Lim, Hyun-Ju
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.2
    • /
    • pp.81-89
    • /
    • 2012
  • This research, which was conducted for student at department of dental hygiene, intended to measure the level of self-efficacy and consciousness on the use of radiation, knowledge and attitude on radiation safety management and got the following conclusions. This study was performed from May 8 to July 7, 2011 for 326 students who study at Department of Dental Hygiene of a three-year course in Busan areas. The result of as follows; 1. As a result of comparing the average of a sense of self-efficacy according to the characteristics of those surveyed, a statistically significant difference(p<0.01)(p<0.001) was found according to grade point average, subjective health condition. 2. As a result of comparing the average level of consciousness about radiation use according to the characteristics of those surveyed, a statistically meaningful difference(p<0.05)(p<0.01) was found according to grade, grade point average. 3. As a result of conducting a correlation analysis among self-efficacy, consciousness on the use of radiation, knowledge and attitude on RSM, the correlation of self-efficacy and consciousness, knowledge, and attitude was r=0.108, 0.203, 0.231 respectively, all of which was a plus correlation(p<0.01). we believe that a variety of programs should be offered to be capable of enhancing knowledge and attitude on RSM, self-efficacy.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF