• Title/Summary/Keyword: Average of Floor

Search Result 376, Processing Time 0.028 seconds

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

Crime Incident Prediction Model based on Bayesian Probability (베이지안 확률 기반 범죄위험지역 예측 모델 개발)

  • HEO, Sun-Young;KIM, Ju-Young;MOON, Tae-Heon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.89-101
    • /
    • 2017
  • Crime occurs differently based on not only place locations and building uses but also the characteristics of the people who use the place and the spatial structures of the buildings and locations. Therefore, if spatial big data, which contain spatial and regional properties, can be utilized, proper crime prevention measures can be enacted. Recently, with the advent of big data and the revolutionary intelligent information era, predictive policing has emerged as a new paradigm for police activities. Based on 7420 actual crime incidents occurring over three years in a typical provincial city, "J city," this study identified the areas in which crimes occurred and predicted risky areas. Spatial regression analysis was performed using spatial big data about only physical and environmental variables. Based on the results, using the street width, average number of building floors, building coverage ratio, the type of use of the first floor (Type II neighborhood living facility, commercial facility, pleasure use, or residential use), this study established a Crime Incident Prediction Model (CIPM) based on Bayesian probability theory. As a result, it was found that the model was suitable for crime prediction because the overlap analysis with the actual crime areas and the receiver operating characteristic curve (Roc curve), which evaluated the accuracy of the model, showed an area under the curve (AUC) value of 0.8. It was also found that a block where the commercial and entertainment facilities were concentrated, a block where the number of building floors is high, and a block where the commercial, entertainment, residential facilities are mixed are high-risk areas. This study provides a meaningful step forward to the development of a crime prediction model, unlike previous studies that explored the spatial distribution of crime and the factors influencing crime occurrence.

Effect of heat stress on growth performance and physiological changes of pigs in commercial farm (고온스트레스가 일반 양돈농가의 돼지 생산성 및 생리 변화에 미치는 영향)

  • Oh, Seo Young;Jeong, Yong Dae;Kim, Doo Wan;Min, Ye Jin;Yu, Dong Jo;Kim, Ki Hyun;Kim, Young Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.130-139
    • /
    • 2017
  • This study investigated the effect of heat stress on the performance and blood characteristics in commercial pig farms. A total of 180 growing pigs and 180 finishing pigs were assigned to two treatments consisting of thermal-neutral period(TNP) and high-temperature period(HTP) with three replications in floor pen, respectively. Feeding trials in the TNP and HTP were individually performed in autumn and summer seasons, respectively. Temperature-humidity index(THI) was calculated by temperature and humidity. Performance and physiological responses were identified per growth stages and feeding trial. Average temperature and THI were $16.8^{\circ}C$ and 61.4 at the TNP, and $25^{\circ}C$ and 74.3 at the HTP, respectively. Growing pigs in HTP exhibited lower BW, ADG and ADFI than in TNP(p<0.01). Similarly, finishing pigs showed lower growth parameters in HTP than in TNP(p<0.01). Lymphocytes and neutrophils of growing pigs were lower in HTP than in TNP(p<0.05). The serum T-PRO and NEFA in finishing pigs were higher in HTP than in TNP(p<0.05). In HTP, finishing pigs had higher cortisol levels than in TNP. Therefore, HTP can negatively influence growth performance and nutritional metabolism in pigs. Our results may provide useful information for developing feeding programs and diets to control heat stress for swine farms.

Risk Factor Analysis for Preventing Foodborne Illness in Restaurants and the Development of Food Safety Training Materials (레스토랑 식중독 예방을 위한 위해 요소 규명 및 위생교육 매체 개발)

  • Park, Sung-Hee;Noh, Jae-Min;Chang, Hye-Ja;Kang, Young-Jae;Kwak, Tong-Kyung
    • Korean journal of food and cookery science
    • /
    • v.23 no.5
    • /
    • pp.589-600
    • /
    • 2007
  • Recently, with the rapid expansion of the franchise restaurants, ensuring food safety has become essential for restaurant growth. Consequently, the need for food safety training and related material is in increasing demand. In this study, we identified potentially hazardous risk factors for ensuring food safety in restaurants through a food safety monitoring tool, and developed training materials for restaurant employees based on the results. The surveyed restaurants, consisting of 6 Korean restaurants and 1 Japanese restaurant were located in Seoul. Their average check was 15,500 won, ranging from 9,000 to 23,000 won. The range of their total space was 297.5 to $1322.4m^2$, and the amount of kitchen space per total area ranged from 4.4 to 30 percent. The mean score for food safety management performance was 57 out of 100 points, with a range of 51 to 73 points. For risk factor analysis, the most frequently cited sanitary violations involved the handwashing methods/handwashing facilities supplies (7.5%), receiving activities (7.5%), checking and recording of frozen/refrigerated foods temperature (0%), holding foods off the floor (0%), washing of fruits and vegetables (42%), planning and supervising facility cleaning and maintaining programs of facilities (50%), pest control (13%), and toilet equipped/cleaned (13%). Base on these results, the main points that were addressed in the hygiene training of restaurant employees included 4 principles and 8 concepts. The four principles consisted of personal hygiene, prevention of food contamination, time/temperature control, and refrigerator storage. The eight concepts included: (1) personal hygiene and cleanliness with proper handwashing, (2) approved food source and receiving management (3) refrigerator and freezer control, (4) storage management, (5) labeling, (6) prevention of food contamination, (7) cooking and reheating control, and (8) cleaning, sanitation, and plumbing control. Finally, a hygiene training manual and poster leaflets were developed as a food safety training materials for restaurants employees.

Characteristic on the Layout and Semantic Interpretation of Chungryu-Gugok, Dongaksan Mountain, Gokseong (곡성 동악산 청류구곡(淸流九曲)의 형태 및 의미론적 특성)

  • Rho, Jae-Hyun;Shin, Sang-Sup;Huh, Joon;Lee, Jung-Han;Han, Sang-Yub
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.24-36
    • /
    • 2014
  • The result of the research conducted for the purpose of investigating the semantic value and the layout of the Cheongryu Gugok of Dorimsa Valley, which exhibits a high level of completeness and scenic preservation value among the three gugoks distributed in the area around Mt. Dongak of Gogseong is as follows.4) The area around Cheongryu Gugok shows a case where the gugok culture, which has been enjoyed as a model of the Neo-Confucianism culture and bedrock scenery, such as waterfall, riverside, pond, and flatland, following the beautiful valley, has been actually substituted, and is an outstanding scenery site as stated in a local map of Gokseong-hyeon in 1872 as "Samnam Jeil Amban Gyeryu Cheongryu-dong(三南第一巖盤溪流 淸流洞: Cheongryu-dong, the best rock mooring in the Samnam area)." Cheongryu Gugok, which is differentiated through the seasonal scenery and epigrams established on both land route and waterway, was probably established by the lead of Sun-tae Jeong(丁舜泰, ?~1916) and Byeong-sun Cho(曺秉順, 1876~1921) before 1916 during the Japanese colonization period. However, based on the fact that a number of Janggugiso of ancient sages, such as political activists, Buddhist leaders, and Neo-Confucian scholars, have been established, it is presumed to have been utilized as a hermit site and scenery site visited by masters from long ago. Cheongryu Gugok, which is formed on the rock floor of the bed rock of Dorimsa Valley, is formed in a total length of 1.2km and average gok(曲) length of 149m on a mountain type stream, which appears to be shorter compared to other gugoks in Korea. The rock writings of the three gugoks in Mt. Dongak, such as Cheongryu Gugok, which was the only one verified in the Jeonnam area, total 165 in number, which is determined to be the assembly place for the highest number of rock writings in the nation. In particular, a result of analyzing the rock writings in Cheongryu Gugok totaling 112 places showed 49pieces(43.8%) with the meaning of 'moral training' in epigram, 21pieces (18.8%) of human life, 16pieces(14.2%) of seasonal scenery, and 12pieces(10.6%) of Janggugiso such as Jangguchur, and the ratio occupied by poem verses appeared to be six cases(3.6%). Sweyeonmun(鎖烟門), which was the first gok of land route, and Jesiinganbyeolyucheon(除是人間別有天) which was the ninth gok of the waterway, corresponds to the Hongdanyeonse(虹斷烟鎖) of the first gok and Jesiinganbyeolyucheon of the ninth gok established in Jaecheon, Chungbuk by Se-hwa Park(朴世和, 1834~1910), which is inferred to be the name of Gugok having the same origin. In addition, the Daeeunbyeong(大隱屛) of the sixth gok. of land route corresponds to the Chu Hsi's Wuyi-Gugok of the seventh gok, which is acknowledged as the basis for Gugok Wollim, and the rock writings and stonework of 'Amseojae(巖棲齋)' and 'Pogyeongjae(抱經齋)' between the seventh gok and eighth gok is a trace comparable with Wuyi Jeongsa(武夷精舍) placed below Wuyi Gugok Eunbyeon-bong, which is understood to be the activity base of Cheongryu-dong of the Giho Sarim(畿湖士林). The rock writings in the Mt. Dongak area, including famous sayings by masters such as Sunsaeuhje(鮮史御帝, Emperor Gojong), Bogahyowoo(保家孝友, Emperor Gojong), Manchunmungywol(萬川明月, King Joengjo), Biryeobudong(非禮不動, Chongzhen Emperor of the Ming Dynasty)', Samusa(思無邪, Euijong of the Ming Dynasty), Baksechungpwoong(百世淸風, Chu Hsi), and Chungryususuk-Dongakpungkyung(淸流水石 動樂風景, Heungseon Daewongun) can be said to be a repository of semantic symbolic cultural scenery, instead of only expressing Confucian aesthetics. In addition, Cheongryu Gugok is noticeable with its feature as a cluster of cultural scenery of the three religions of Confucian-Buddhism-Taoism, where the Confucianism value system, Buddhist concept, and Taoist concept co-exists for mind training and cultivation. Cheongryu Gugok has a semantic feature and spatial character as a basis for history and cultural struggle for the Anti-Japan spirit that has been conceived during the process of establishing and utilizing the spirit of the learning, loyalty for the Emperor and expulsion of barbarians, and inspiration of Anti-Japan force, by inheriting the sense of Dotong(道統) of Neo-Confucianism by the Confucian scholar class at the end of the Joseon era that is represented by Ik-hyun Choi(崔益鉉, 1833~1906), Woo Jeon(田愚, 1841~1922), Woo-man Gi(奇宇萬, 1846~1916), Byung-sun Song(宋秉璿, 1836~1905), and Hyeon Hwang(黃玹, 1855~1910).

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF