• 제목/요약/키워드: Average of Floor

검색결과 376건 처리시간 0.029초

참나무류(類)의 제습태양열건조(除濕太陽熱乾燥)의 조건(條件), 속도(速度), 결함(缺陷), 수율(收率) 및 열효율(熱效率)과 관행(慣行) 천연(天然), 반온실형(半溫室型) 태양열(太陽熱) 및 열기건조(熱氣乾燥)와의 비교(比較)·분석(分析) (The Comparative Analysis of Drying-Conditions, -Rates, -Defects and Yield, and Heat-Efficiency in Solar-Dehumidification-Drying of Oaks With Those in Conventional Air-, Semi-Greenhouse Type solar-, and Kiln- Drying)

  • 이형우;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제17권1호
    • /
    • pp.22-54
    • /
    • 1989
  • Seasonal semi-greenhouse type solar-drying of 2.5cm-and 5.0cm-thick lumber of Quercus aliena Blume and Quercus variailis Blume was carried out to investigate the possibility of solar-drying of wood and to decide the active solar-drying period in Korea. In the active solar-drying period obtained solar-dehumidification, semi-greenhouse type solar-, air- and kiln-drying of 2.5cm -thick lumber of oaks were carried out to analyze drying-rates. -defects, and -yield in each drying-method and to calculate daily total absorbed solar-radiation the solar dryers. The energy balance equations were set up, considering all the energy requirements, to analyze the heat efficiencies of semi-greenhouse type solar and solar-dehumidification-dryer. In a seasonal drying the drying rate of semi-greenhouse type solar-dryer was highest in summer, and greater in fall, spring, and winter in order. Solar-drying time was 45% in summer to 50% in winter of the air-drying rime, and more serious drying-defects occurred in air-drying than in solar-drying. In the active solar-drying period. April, May, and June, the average drying rate in solar-dehumidification-drying was 1.0%/day and greater than 0.8%/day in semi-greenhouse type solar-drying. In solar-dehumidification-drying the time required to dry lumber to 10% moisture content was less than 60 days, and solar-dehumidification-drying showed the highest drying-yield, 65.01%, than the other drying methods. The daily total absorbed solar radiations were 8.51MJ on the roof collector and 6.22 MJ on the south wall collector. In the energy blance 69.48% of total energy input was lost by heat conduction through walls, roof. and floor 11.68% by heat leakage, 0.33% by heating the internal structures of the solar-dryer and 5.38% by air-venting. Therefore the heat efficiency of semi-greenhouse type solar-dryer 13.13%, was lower than that of solar-dehumidification-dryer, 14.04%. Solar-drying of lumber in Korea showed the possibility to reduce the air-drying-time in every season and the efficiency of solar-dehumidification drying was higher than that of semi-greenhouse type solar-drying.

  • PDF

중왕산 천연활엽수림에서 고로쇠나무 낙하종자량 및 종자활력의 연년변이 연구 (A Study on the Interannual Variation of Seedfall and Seed Viability of Acer pictum subsp. mono in Natural Broadleaved Forests at Mt. Jungwang)

  • 김회진;김갑태
    • 한국환경생태학회지
    • /
    • 제29권4호
    • /
    • pp.503-507
    • /
    • 2015
  • 고로쇠나무의 낙하종자량과 종자활력의 연년변이와 그 원인을 밝혀보고자, 평창군 소재의 중왕산 천연활엽수림에서 종자트랩을 설치하여 낙하종자량과, 낙하종자의 활력을 6년(2009~2014)간 조사하였다. 2009년부터 2014년까지의 낙하종자량은 각각 55,700, 4,060, 60,900, 45,670, 403,450 ea/ha였으며, 2014년에는 310ea/ha로 평년에 비하여 매우 적은 양이었다. 2013년은 고로쇠나무 종자풍년(masting year)이었다고 판단된다. 종자활력 간 낙하종자량은 통계적 유의차가 인정되었다. 가장 많은 낙하종자는 피해 또는 부후된 종자이며 평균 47.88%였고, 다음으로 쭉정이 종자, 미발육 종자, 건전종자 순으로 낮아졌다. 건전종자는 6.7~31.0% 범위, 평균은 16.74%로 가장 낮았다. 종자풍년인 2013년에 건전종자는 평년(320~17,840ea/ha)보다 월등히 많은 125,070ea/ha이 숲바닥에 떨어졌다. 한편 피해 또는 부후종자의 비율이 38%로 가장 낮았으나, 종자립수는 153,310립/ha로 가장 많았다. 이러한 결과는 종자풍년에 천연갱신을 위한 충분한 건전종자가 공급됨을 암시하고, 포식자물림 가설(seed predator satiation hypothesis)을 지지한다고 사료된다. 연구가 미흡한 활엽수종의 종자생산에 대한 장기연구가 필요하다고 사료된다.

지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가 (Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation)

  • 이지현;강명지;박윤경;박동욱;최상준
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.

2주간 압력 생체되먹임 기구를 이용한 케겔 운동이 최대 자발적 환기량과 배 근육 두께에 미치는 영향 (Effect of Kegel Exercise Using Pressure Biofeedback Unit for 2 Weeks on Maximum Voluntary Ventilation and Abdominal Muscle Thickness)

  • 박한규;이정희;김초희;윤주미;조예은;이소희
    • 대한통합의학회지
    • /
    • 제10권4호
    • /
    • pp.175-185
    • /
    • 2022
  • Purpose : This study was conducted to determine the effect of Kegel exercise using a pressure biofeedback unit (PBU) for 2 weeks on maximum voluntary ventilation (MVV) and abdominal muscle thickness based on previous studies. Methods : The subjects of this study were 20 healthy female students in their 20s. Subjects were randomly assigned to two groups. Eleven subjects were assigned to the experimental group (EG) and 9 subjects were assigned to the control group (CG). Subjects measured MVV with a spirometer. In hooklying position, transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) of the dominant side were measured using ultrasound. For the measurement value, the average value of three times was adopted. After 2 weeks of intervention, the measurements were measured in the same way. In the EG, pelvic setting training using PBU was performed before Kegel exercise. The PBU was first placed at the waist in the Kegel exercise position and the starting pressure was set at 40 mmHg and adjusted to 60 mmHg through pelvic floor muscle contraction. After performing pelvic control using PBU, Kegel exercise was performed with 8 seconds of contraction, 8 seconds of relaxation, and 3 sets of 10 reps per set. A significance level of 𝛼=.05 was used to verify statistical significance. Results : In the variable of MVV, a significant increase was confirmed in the EG (p<.05). In the abdominal muscle thickness variable, significant increases were confirmed in IO and TrA in the EG (p<.05). In addition, a significant increase in IO was confirmed in the CG (p<.05). Significant increases in IO and TrA were confirmed between groups (p<.05). Conclusion : Based on the previous study, this study confirmed that Kegel exercise using a PBU had a positive effect on MVV and abdominal muscle thickness based on a 2-week intervention.

일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가 (Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings)

  • 정은교;김기웅
    • 한국산업보건학회지
    • /
    • 제27권1호
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

화순 운주사 원형다층석탑의 재질특성과 훼손도 평가 (Material Characteristics and Deterioration Assessment for Multi-storied Round shape Stone Pagoda of Unjusa Temple, Hwasun, Korea)

  • 박성미;이명성;김재환;이찬희
    • 헤리티지:역사와 과학
    • /
    • 제45권1호
    • /
    • pp.86-101
    • /
    • 2012
  • 운주사 원형다층석탑의 주요 구성암석은 암편질응회암과 유문암질 각력응회암으로 담녹색 및 회색을 띠며 원마도가 불량한 암편을 함유하고 있다. 암편질응회암은 유리질 기질과 은미정질의 장석과 석영이 보이고 미정질 결정들이 나타난다. 유문암질 각력응회암에서는 장석 및 불투명 광물로 이루어진 기질에 석영과 장석이 반정으로 관찰된다. 석탑의 모든 부재에는 먼지, 박리박락, 공동, 탈락, 균열이 발달되어 있으며, 적외선 열화상 촬영 결과 부분적으로 내부 공극이 상당히 진행되어 박리를 유발하고 있는 상태이다. 또한 서측과 북측의 3층 이상 옥개석 상부에서는 회색, 녹색, 황갈색 등의 다양한 지의류 및 선태류들이 높은 점유율을 보인다. 기단부와 옥개석에는 산화망간, 산화철 및 수산화철 등의 무기오염물에 의한 변색이 나타난다. 석탑 부재의 화학적 풍화지수(CIA)와 풍화잠재지수(WPI)를 산출한 결과, 각각 55.69, 1.12로 상당히 풍화가 진행되었으며 초음파속도는 평균 2,892m/s, 풍화도지수와 일축압축강도는 각각 0.4k, $1,096kg/cm^3$로 암석의 강도와 내구성이 약화된 상태이다.

시스템 다이내믹스 기법을 활용한 성남시 토지이용수요 예측에 관한 연구 (A Study on Prediction of Land Use Demand in Seongnam-city Using System Dynamics)

  • 이미숙;신동빈;김창훈
    • 한국측량학회지
    • /
    • 제40권4호
    • /
    • pp.261-273
    • /
    • 2022
  • 본 연구는 시스템 다이내믹스 기법을 활용하여 성남시의 토지이용수요를 예측하고 가족구조 변화와 토지이용밀도 조정정책이 토지이용수요에 미치는 영향을 모의실험하는데 연구의 목적이 있다. 이를 위해 분석모형을 설계하고 시뮬레이션 결과를 통해 시간의 흐름에 따른 토지이용수요의 변화를 살펴보았다. 분석결과에 의하면, 2035년 기준으로 주거용지는 2.08km2, 상업용지는 1.36km2의 추가 공급이 필요하고, 공업용지는 현재 공급면적으로 수요를 충족할 수 있는 것으로 나타났다. 한편, 기본 모형에서 변수값을 변경하여 세가지 정책실험을 실시하였다. 첫 번째 정책실험에서는 가구원수가 기본 모형에 비해 급격히 감소할 경우에는 주거용지가 최대 7.99km2 추가공급이 필요한 것으로 나타났다. 두 번째 정책실험에서는 아파트 용적율이 200%에서 300%로 상향하면 현재의 성남시 주거지역 공급면적으로 주거용지 수요 충족이 가능하였다. 세 번째 정책실험에서는 상업지역 평균층수를 4층에서 5층 상향하고 상업지역 건폐율을 80%에서 85%로 상향하더라도 상업용지의 수요가 성남시 상업지역 공급면적을 초과하는 것으로 나타났다. 본 연구는 시스템 다이내믹스를 활용하여 토지이용수요 예측의 새로운 분석모형을 제시하고, 성남시의 실제 도시계획 현황 및 통계치를 적용하여 모형을 실증하였다는데 연구의 의의가 있다. 향후 성남시 토지이용수요 예측 및 분석 모형의 정교화를 위한 후속연구가 이루어져야 할 것이다.

노인요양시설 거주 노인의 낙상 위험요인 조사 연구 (Fall Risk Assessment of the Elderly living in Nursing Home)

  • 양선희;박영혜;조혜숙;백희정
    • 가정∙방문간호학회지
    • /
    • 제12권2호
    • /
    • pp.1-15
    • /
    • 2005
  • Purpose: This study was conducted to assess the fall risk factors. Method: The subjects were 87 persons who were older than 65 years living at 28 nursing home in Seoul and Gyunggi province. Subjects were interviewed using RAFS II for intrinsic factor and the environmental factor were assessed using a structured questionnaire from Oct. to Dec. in 2004. The data were analyzed by SPSS(ver. 12.0) programs, using descriptive statistics, $x^2$-test, and t-test. Result: The 37.9% of the subjects experienced the fall, and its average number is $1.94\pm1.75$. The Women's experience of the fall was higher than that of the men, but it was no significant difference with gender. There was no significant difference with the age and duration of living. The mean of the intrinsic risk factor was 13.38 in total score 39 points marks on the RAFS II scales. The intrinsic risk factor score of the fallen group 15.71 was significantly higher than the non-fallen group 12.10. The variables of recent fall experience(t=4.72, p=0.000) and urinary dysfunction(t=2.64, p=0.010) was significantly higher than the non-fallen group. The highest variable of the intrinsic factor was the age and the variables of drug intake, balance, chronic disease, recent fall experience, urinary dysfunction were followed in order. The mean of the environmental risk factor was 0.24 points. No significant differences were shown in environmental risk factor between the fallen and the non-fallen groups. To the fallen group, the place of entrance was the highest risky environmental factor. To see in area dimension, the floor surfaces was the highest risky environmental factor and equipment and illumination factor was the following risky elements in order. In the total score of environmental risk factors based on the ares, the fallen group was 0.26 and the non-fallen group was 0.24, but there were no significant differences between the groups. Conclusion: This results suggested that visual protection strategy, set up the safety device in the place of entrance and inner stairway, bathroom and nonskid mat in the nursing home would be contribute to the prevention of the fall for the elderly.

  • PDF

Differences in bedding material could alter the growth performance of White Pekin ducks raised for 42 days

  • Elijah Ogola Oketch;Yu Bin Kim;Myunghwan Yu;Jun Seon Hong;Shan Randima Nawarathne;Jung Min Heo
    • Journal of Animal Science and Technology
    • /
    • 제65권2호
    • /
    • pp.377-386
    • /
    • 2023
  • The effect of different commercially available bedding materials on the growth performance and carcass characteristics of ducks for 42 days was investigated. 336 one-day-old White-Pekin ducklings (60.48 ± 0.16 g) were randomly allocated into 24-floor pens with one of the three beddings namely i) coco peat, ii) rice husks, or iii) sawdust. 14 ducklings per pen and 8 replicate pens per bedding material were used. Birds were fed a starter diet from days 1-21 and a grower diet from days 22-42. Weekly growth performance evaluation was conducted for the average body weight, weight gains, daily feed intake, and feed conversion efficiency. One bird per pen was sacrificed on day 42 for the evaluation of carcass characteristics including the carcass, breast, and leg muscle percentages. Breast and leg muscle samples were then collected and analyzed for their proximate and pH values. Higher body weights (p < 0.05) were noticed with rice husks on day 42 only. Improved daily gains (p < 0.05) were also noticed for birds raised with rice husks over the entire period (days 1-42). Concerning feed intake, higher values (p < 0.05) were similarly noted with rice husks for the grower phase (days 22-42), and the entire experimental period (days 1-42). Marginally improved feed intake values were also noted with the use of rice husks as the bedding materials on day 42 (p = 0.092). Improved feed efficiency (p < 0.05) was noticed with rice husks on day 35, the grower period, and the entire 42-day period. However, no significant differences were noticed for most of the carcass characteristics that were evaluated. Nevertheless, higher (p < 0.05) pH values for the breast muscle were noticed with the use of coco peat and sawdust as the bedding. Conclusively, the bedding type could have a significant impact on the growth performance of ducks without adverse effects on carcass characteristics. The use of rice husks as bedding might be advantageous and is therefore recommended.

역세권 특성이 지하철 이용수요에 미치는 영향분석 (An Empirical Study on the Relationship between Subway Trips and Characteristics of Subway Catchment Area.)

  • 조현우;이석환;신강원
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.5191-5198
    • /
    • 2010
  • 지하철 이용수요와 토지이용, 개발밀도, 환승교통체계, 접근성과 같은 다양한 역세권 특성의 관계를 규명하기 위한 많은 연구들이 추진되어 왔으나, 역세권내 보행 가로망 구조와 지하철 이용수요간의 관계에 관한 분석은 미비한 실정이다. 본 연구는 부산광역시 79개 지하철 역세권내 가로망의 구조를 공간구문론(Space syntax)을 이용하여 평가하였으며, 역세권내 가로망 구조의 접근성을 포함한 다양한 역세권 특성이 지하철 이용수요에 미치는 영향을 실증분석을 하였다. 분석결과 역세권 가로망 구조를 대변할 수 있는 공간지표인 통합도, 연결도, 명료도 중 역세권 가로망의 접근 편의성을 나타내는 통합도가 높을수록 지하철 이용수요가 증가하는 것으로 나타났다. 또한 역세권 토지이용형태와 개발밀도를 각각 반영하는 집객시설 집중도와 용적률이 높을수록 지하철 이용수요가 증가하는 것으로 나타났다. 따라서 부산광역시의 지하철 역세권 구조를 대중교통 중심의 개발 체계로 개선하기 위해서는 역세권내 보행가로의 접근성을 향상시킬 수 있는 가로 설계와 통행 목적성이 강한 도시시설물을 압축 고밀의 건축물에 조성하기 위한 노력들이 추진되어야 할 것으로 판단된다.