• Title/Summary/Keyword: Average of Floor

Search Result 377, Processing Time 0.02 seconds

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

Pelvic Floor Muscle Exercise by Biofeedback and Electrical Stimulation to Reinforce the Pelvic Floor Muscle after Normal Delivery

  • Lee, In-Sook;Choi, Euy-Soon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.8
    • /
    • pp.1374-1380
    • /
    • 2006
  • Purpose. This study was conducted to investigate the effectiveness of pelvic floor muscle exercise using biofeedback and electrical stimulation after normal delivery. Methods. The subjects of this study were 49 (experimental group: 25, control group: 24) postpartum women who passed 6 weeks after normal delivery without complication of pregnancy, delivery and postpartum. The experimental group was applied to the pelvic muscle enforcement program by biofeedback and electrical stimulation for 30 minutes per session, twice a week for 6 weeks, after then self-exercise of pelvic floor muscle was done 50-60 repetition per session, 3 times a day for 6 weeks. Maximum pressure of pelvic floor muscle contraction (MPPFMC), average pressure of pelvic floor muscle contraction (APPFMC), duration time of pelvic floor muscle contraction (DTPFMC) and the subjective lower urinary symptoms were measured by digital perineometer and Bristol Female Urinary Symptom Questionnaire and compared between two groups prior to trial, at the end of treatment and 6 weeks after treatment. Results. The results of this study indicated that MPPFMC, APPFMC, DTPFMC were significantly increased and subjective lower urinary symptoms were significantly decreased after treatment in the experimental group than in the control group. Conclusions. This study suggested that the pelvic floor muscle exercise using biofeedback and electrical stimulation might be a safer and more effective program for reinforcing pelvic floor muscle after normal delivery.

A Study on Comparison of Capacity between Wet.Dry Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.567-570
    • /
    • 2009
  • The present study conducted comparative evaluation of wet dry floor heating systems using geothermal heat pump. Circulation hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler was used. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.89^{\circ}C$ for wet type and $32.66^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. In the results, for floor heating system using low temperature circulation water, wet type was not enough to meet stable and comfortable radiant floor heating due to low floor temperature and access time to indoor set temperature. While dry type was practicable for stable floor heating due to fast rise of indoor set temperature and comfortable floor temperature.

  • PDF

A study on the proportion of plans and elevations in traditional architecture - Focused on the period of Joseon - (전통 건축에 있어서 평면 및 입면의 비례 연구 - 조선시대 중심으로 -)

  • Seo, Hyun-Su;Kong, Sung-Hoon;An, Chang-Hwan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.91-94
    • /
    • 2009
  • The purpose of this study is to research the proportion of plans and elevations in traditional architecture for period of Joseon. The collected data of traditional buildings are analyzed for the basic design methods; horizontal factors and vertical factors for floor plans and front elevations. The results of the analysis on this study are as follows. Proportion data of floor plans in traditional architecture is from 1 : 3.8 to 1 : 1.21. Proportion data of front elevations in traditional architecture is from 1 : 8.1 to 1 : 1.03. Average proportion of floor plans in traditional architecture is 1.87. Average proportion of front elevations in traditional architecture is 2.59.

  • PDF

Comparative Study on Performance of Wet-type and Dry-type Floor Heating Systems Using Geothermal Heat Pump (지열히트펌프를 이용한 습식.건식 바닥난방 성능평가 연구)

  • Lee, Byoung-Doo;Lee, Se-Jin;Lee, Dae-Woo;Oh, Sung-Hae;Nam, Woo-Dong
    • New & Renewable Energy
    • /
    • v.5 no.4
    • /
    • pp.60-65
    • /
    • 2009
  • The present study was conducted for a comparative evaluation of wet and dry floor heating systems using geothermal heat pump. We circulated hot water from geothermal heat pump which is $10{\sim}15^{\circ}C$ lower than that from boiler. In order to access indoor temperature ($25^{\circ}C$) it took 74 minutes for dry type and 247 minutes for wet type. Average floor temperature was $23.9^{\circ}C$ for wet type and $32.7^{\circ}C$ for dry type. Energy saving rate gradually increased by 66% after 138 minutes. As a result, in case of floor heating system using low temperature circulation water, dry type was more practicable for stable floor heating than wet type in terms of floor temperature and access time to indoor set temperature.

  • PDF

Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load (직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토)

  • Kim, Soo-Kyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

Trend Analysis of Men's Gymnastics on Floor Exercise in the 2018 Asian Games through Digital Video Materials (디지털 영상자료를 통한 2018 아시안게임 기계체조 마루운동에 대한 연기내용 분석)

  • Han, Yoon-Soo
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.619-624
    • /
    • 2018
  • The purpose of this study was to examine the trend of men's gymnastics on floor exercise final(8 gymnasts) in the 2018 Asian Games through digital video materials. Video recordings of floor exercise final were collected from the 2018 Asian Games. The cross-check with three international gymnastics judges on floor exercise final was analyzed. To fulfil the D-score, 8 gymnasts were the most performed backward saltos elements group(36 elements), forward salto with 1/1 turn(8 gymnasts), backward salto with 5/2 turn(8 gymnasts) and backward salto with 3/1 turn(8 gymnasts). The scores showd average the D score 6.0, E score 7.9, and connection values 0.25. To get a good results on floor exercise, gymnasts need to get a average the D score over 6.0, E score over 8.5, and connection values over 0.3.

Effects of semi-floor pens on growth performance and stress in weaning pigs (사육면적 증가를 위한 반층돈사의 활용이 이유자돈의 성장 및 스트레스에 미치는 영향)

  • Chung, Woolim;Lee, Geonil;Hong, Jinsu;Jeong, Jaehark;Kim, Yooyong
    • Journal of Animal Environmental Science
    • /
    • v.22 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The objective of this study was to increased breeding area in same size pig pen and growth performance of weaning pigs. A total of 330 crossbred ($6.68{\pm}0.36kg$) weaning pigs were subjected to a 42-day feeding trial(3 pens/treatment) in which effects of the semi-floor were compared : NC; Negative control ($0.23m^2/pig$; 40 pigs/pen), PC; Positive control($0.30m^2/pig$; 30 pigs/pen) and Semi-floor($0.30m^2/pig$; 40 pigs/pen). There was a significant effect on BW at 6 week along all treatment(P<0.01). There was a effect of Semi-floor treatment on ADG(average daily gain) only during the first 3 week after weaning(P<0.01). No significant effect was observed in the ADFI during the experiment period. NC treatment had significantly lower BUN value than other treatments(P<0.05). The results from immune and stress response with semi-floor suggest that no negative effects in their blood analysis. Consequently, semi floor treatments increased additional breeding area and also growth performance rather than other treatments in weaning pigs.

The Variation of Top Floor Indoor Thermal Environment with Roof Storage Using Model Experiment (옥상 저류조 설치에 따른 최상층 실내열환경 변화에 관한 모형 실험연구)

  • Park, Bong-Gil;Lee, Kyung-Hee;Jang, Seung-Jae
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.105-112
    • /
    • 2009
  • The purpose of this study is to investigate a top floor, indoor, thermal environment by comparison between the indoor air temperature and the rooftop surface temperature, and between the indoor air temperature and the outdoor air temperature using an experimental model. The model experiment was conducted with 4 cases,: no-rainfall, 1 em-height, 10 em-height and 20em-height of rainfall on the rooftop. According to the results of the height of stored rainfall, the average air temperature difference between the indoor and outdoor air with 1, 10 and 20 em-height of rainfall on the rooftop was $4.0^{\circ}C$, rooftop $1.2^{\circ}C$ and rooftop $1.0^{\circ}C$, respectively. The upper 10 em-height of rainfall on the rooftop acted to decrease the indoor air temperature on the top floor.

Orbital wall restoring surgery with resorbable mesh plate

  • Joo, Jae Doo;Kang, Dong Hee;Kim, Hyon Surk
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.264-269
    • /
    • 2018
  • Background: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. Methods: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results: The OVR decreased significantly, by an average of 6.01% (p<0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p<0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. Conclusion: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.