• Title/Summary/Keyword: Average of Floor

Search Result 378, Processing Time 0.021 seconds

Clothing Pressure Sensation and Discomfort Experience of Skinny Jean (여대생의 스키니 진 착용 실태 및 주관적 압박감)

  • Na, Young-Joo;Lee, Dong-Wook
    • Korean Journal of Human Ecology
    • /
    • v.19 no.4
    • /
    • pp.655-665
    • /
    • 2010
  • This study analyzed the effects of skinny jean on women's health by questionnaire survey and measuring the pressure experienced under the clothing and participants' subjective view of the pressure level. The average size women in their 20s' waists is 26 inches and so three pairs of jeans were prepared and worn by 4 female participants. A survey was conducted to investigate how often participants wear skinny jeans and whether they had had any feelings of discomfort as a result of this. Participants responded that they hadexperienced middle to high levels of discomfort due to the high pressure inside skinny jeans. For the maximum value of clothing pressures, jean f2 at the part of buttocks showed $48.7gf/cm^2$. The pressure inside the clothing was found to be highest around the buttocks followed by the knees and finally the belly. The mean values of 7 measuring parts are different according to the jean type; f3 $20.8gf/cm^2$ > f2 $16.4gf/cm^2$ > f1 $15.5gf/cm^2$, which is corresponding to the order of pressure sensation, but not corresponding to the order of ease amount of clothing pattern: f2 > f3 > f1. Mean pressure values were also measured according to the body posture: they were found to by highest when sitting on a chair (21.3gf/$cm^2$), second highest when sitting on the floor ($19.2gf/cm^2$) and lowest when standing ($15.0gf/cm^2$). This is not always same to the order of participants subjective perceptions of the pressure, which is, they estimated pressure to be highest when sitting on the floor followed by sitting on a chair and lowest in a standing position.

Current Status of Lighting System and Illumination Distribution in the Greenhouse for Light Culture of Strawberries (딸기 전조재배 온실의 인공광 설치실태 및 조도분포 조사분석)

  • 김태한;장익주;이경진
    • Journal of Biosystems Engineering
    • /
    • v.24 no.1
    • /
    • pp.19-24
    • /
    • 1999
  • Motivated by the need for developing the more efficient lighting system for light culture of strawberries in the greenhouse, this paper aims at acquiring and suggesting more concrete and scientific foundation of illuminating position, numbers of light source by investigating the types of lighting system and illumination distribution in the greenhouse for light culture of strawberries. The results of investigation and experiment are summarized as following below: 1. The types of lighting system used in the greenhouse producing strawberries were classified as 1 line and 2 lines lighting system. 2. As for the arranging types of artificial light, 2 lines lighting system, were classified as Z-type, N-type and W-type. (Refer Fig. 3) 3. The results of illumination distribution for Z-type, N-type and W-type of 2 lines illuminating system in the greenhouse with a small size tunnel measured at the height of 1.5m from the ground with 220V, 100W lamp in 6m light gap showed that maximum illuminance are 961x, 1211x, 1251x, minimum illuminance are 4.41x, 4.71x, average illuminance are 33.71x, 43.11x, 44.51x and standard deviations are 28.31x, 35.41x, 38.31x at each types. 4. Proportion of the area below optimal illuminance to floor area at the two lines illuminating system of Z-, N-, and W-type in greenhouse were appeared as 39.4%, 26.0% and 26.3%, respectively. Also proportion of the area over optimal illuminance to floor area at the two lines illuminating system of Z-, N-, W-type in greenhouse were appeared as 16.8%, 14% and 14.7%, respectively. Thus N-type was superior to the others from the view points of optimal illumination distribution and energy saving.

  • PDF

Distribution Characteristics and Cost Estimation of Collection and Treatment of Deposited Marine Debris in Coastal Fisheries around the Southwestern Islands of Korea (서남해 주요 도서 연안 어장 침적쓰레기의 분포 실태 조사 및 수거 처리 비용 추정)

  • Kim, Seondong;Kang, Wonsoo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.15 no.4
    • /
    • pp.330-336
    • /
    • 2012
  • We surveyed and evaluated quantities and distribution characteristics of debris on the sea floor around active fishing grounds around the islands in the southwest coast of Korea in 2007 where the average depth is below 40m. Proper recovery gears mainly to haul the derelict fishing gears are selected considering the sea bed types of the areas. The collected debris amounts were used to estimate the total amount of the surveyed area. The number of hauls per trial times the amount of the debris was extended to whole sampling area and the weighting factor from the opinion was applied to reach the total amount of marine debris on the floor. The amount of the deposited marine debris around Wangdeung-do area is estimated as about 686 $kg/km^2$, and the cost of the collection and treatment for the deposited marine debris is estimated about 3.9 billion KRW after consideration of the proper size of the working ships, labor, transport and treatment cost.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

A Preliminary Study of the Effect of Kegel Exercise Using a Pressure Biofeedback Unit on Maximum Voluntary Ventilation and Abdominal Muscle Thickness (압력 생체되먹임 기구를 이용한 케겔 운동이 최대 수의적 환기량과 배 근육 두께에 미치는 사전 연구)

  • Lee, Kyung-Soon;Park, Kang-Hui;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose : Kegel exercises reported that it is effective in managing stress-related or complex urinary incontinence through contraction and relaxation of the pelvic floor muscles. In many previous studies, it was confirmed that Kegel exercise is involved in respiration as well as urinary system diseases. However, there is a lack of research on the effect of pelvic setting when performing Kegel exercises. Therefore, this study was conducted to investigate the effect on maximum voluntary ventilation (MVV) and abdominal muscle thickness through Kegel exercise after lumbar-pelvic motor control using pressure biofeedback unit (PBU). Methods : The subjects of this study were 10 healthy female students in their 20s. Subjects measured MVV with a spirometer. In hooklying, external oblique, internal oblique, and transverse abdominis of the dominant hand were measured using ultrasound. The measured value was an average of three times. After one week of intervention, measurements were made in the same manner. Before Kegel exercise, pelvic setting training was performed using PBU. In hooklying, PBU was placed in the waist and set to 40 mmHg, and it was adjusted to 60 mmHg through pelvic muscle contraction. For Kegel exercise, the pelvis was first set using PBU, and then the pelvic floor muscles were contracted for 8 seconds and relaxed for 8 seconds, 10 times, 1 set, and 3 sets. Results : In MVV, a significant difference was confirmed after exercise than before exercise (p<.05). There was also a significant difference in abdominal muscle thickness before and after exercise (p<.05). Conclusion : Based on the results of this study, Kegel exercise using PBU had an effect on MVV and abdominal muscle thickness. However, since this study was conducted without a control group as a preliminary study, additional research should be conducted to supplement this.

Estimation of Parking Requirements of an Apartment (공동주택 주차장 설치기준)

  • Oh, Jae Hak;Park, Junsik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.451-457
    • /
    • 2009
  • This study verifies parking requirements of an apartment suggested in parking generation law in Korea through analysing the surveyed parking generation rate. It is revealed that the parking requirements according to the gross floor area in parking generation law is similar to the surveyed parking generation rate as an average but the differences of each requirements by region and apartment's size are not significant. Parking generation rate results in strong correlation with the number of household rather than the gross floor area, and the new requirements suggested in this study, based on the number of household, shows significant difference by region and apartment's size, which is consistent with common sense. This study suggests parking requirements of an apartment, based on the number of household, by region and apartment's size for 6 groups. Surveyed parking generation rate of each group is fitted to statistical distribution and the mean value of fitted statistical distribution is suggested as the parking requirements of each group. Parking requirements based on the number of household is easily recognized of its relative and absolute value, and moreover is consistent with the surveyed parking generation rate.

TREATMMENT OF CHRONIC RUMINATION THROUGH REVERSE OF REINFORCEMENT (행동치료를 통한 시설아동의 만성 구토행위 치료)

  • Chung, Bo-In;Kim, Sin-Ja;Lee, Jum-Sook
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.1 no.1
    • /
    • pp.172-177
    • /
    • 1990
  • The reverse of reinforcement technique was used in treating rumination of a 12-year old (estimated age) mentally retarded child in a residential setting. The subject's rumination pattern was first to vomit the food onto the floor and then to eat it back in several attempts. Consequently, the way to reverse the contingency of rumination in this child was to take away the discharge whenever rumination occurred. An ABAB single subject design was adopted to evaluate the treatment effect. In baseline 1 the frequency of his rumination for 2.5 hours after eating was an average of 46(range= 30-62), while decreased to 6.7 in treatment condition 1. However, when the discharge was not taken away in baseline 2, his rumination increased to 34 times and then decreased to zero to 1 time when the reverse of reinforcement was reinstituted in treatment condition 2. The results clearly indicate that the reverse of reinforcement which was implemented in the form of removing the discharge from the floor was successful. It was reported that the treatment effect has been maintained over 10 months post treatment.

  • PDF

Prediction of Peak Back Compressive Forces as a Function of Lifting Speed and Compressive Forces at Lift Origin and Destination - A Pilot Study

  • Greenland, Kasey O.;Merryweather, Andrew S.;Bloswick, Donald S.
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.236-242
    • /
    • 2011
  • Objectives: To determine the feasibility of predicting static and dynamic peak back-compressive forces based on (1) static back compressive force values at the lift origin and destination and (2) lifting speed. Methods: Ten male subjects performed symmetric mid-sagittal floor-to-shoulder, floor-to-waist, and waist-to-shoulder lifts at three different speeds (slow, medium, and fast), and with two different loads (light and heavy). Two-dimensional kinematics and kinetics were captured. Linear regression analyses were used to develop prediction equations, the amount of predictability, and significance for static and dynamic peak back-compressive forces based on a static origin and destination average (SODA) backcompressive force. Results: Static and dynamic peak back-compressive forces were highly predicted by the SODA, with R2 values ranging from 0.830 to 0.947. Slopes were significantly different between slow and fast lifting speeds (p < 0.05) for the dynamic peak prediction equations. The slope of the regression line for static prediction was significantly greater than one with a significant positive intercept value. Conclusion: SODA under-predict both static and dynamic peak back-compressive force values. Peak values are highly predictable and could be readily determined using back-compressive force assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

Achievable Sum Rate Analysis of ZF Receivers in 3D MIMO Systems

  • Li, Xingwang;Li, Lihua;Xie, Ling
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.4
    • /
    • pp.1368-1389
    • /
    • 2014
  • Three-dimensional multiple-input multiple-output (3D MIMO) and large-scale MIMO are two promising technologies for upcoming high data rate wireless communications, since the inter-user interference can be reduced by exploiting antenna vertical gain and degree of freedom, respectively. In this paper, we derive the achievable sum rate of 3D MIMO systems employing zero-forcing (ZF) receivers, accounting for log-normal shadowing fading, path-loss and antenna gain. In particular, we consider the prevalent log-normal model and propose a novel closed-form lower bound on the achievable sum rate exploiting elevation features. Using the lower bound as a starting point, we pursue the "large-system" analysis and derive a closed-form expression when the number of antennas grows large for fixed average transmit power and fixed total transmit power schemes. We further model a high-building with several floors. Due to the floor height, different floors correspond to different elevation angles. Therefore, the asymptotic achievable sum rate performances for each floor and the whole building considering the elevation features are analyzed and the effects of tilt angle and user distribution for both horizontal and vertical dimensions are discussed. Finally, the relationship between the achievable sum rate and the number of users is investigated and the optimal number of users to maximize the sum rate performance is determined.

Analysis of the Relationship between Three-Dimensional Built Environment and Urban Surface Temperature (도시의 3차원 물리적 환경변수와 지표온도의 관계 분석)

  • Li, Yige;Lee, Sugie;Han, Jaewon
    • Journal of Korea Planning Association
    • /
    • v.54 no.2
    • /
    • pp.93-108
    • /
    • 2019
  • This study examines the relationship between three-dimensional urban built environment and urban surface temperature using LANDSAT 8 satellite image data in Seoul city. The image was divided into 600m×600m grid units as an unit of analysis. Due to the high level of spatial dependency in surface temperature, this study uses spatial statistics to take into account spatial auto-correlation. The spatial error model shows the best goodness of fit. The analysis results show that the three-dimensional built environment and transport environment as well as natural environment have statistically significant associations with surface temperature. First, natural environment variables such as green space, streams and river, and average elevation show statistically significant negative association with surface temperature. Second, the building area shows a positive association with surface temperature. In addition, while sky view factor (SVF) has a positive association with surface temperature, surface roughness (SR) shows a negative association with it. Third, transportation related variables such as road density, railway density, and traffic volume show positive associations with surface temperature. Moreover, this study finds that SVF and SR have different effects on surface temperature in regard to the levels of total floor areas in built environment. The results indicate that interactions between floor area ratio (FAR) and three-dimensional built environmental variables such as SVF and SR should be considered to reduce urban surface temperature.