• 제목/요약/키워드: Average heat transfer coefficient

검색결과 179건 처리시간 0.024초

루버휜형 열교환기내 유동 및 열전달 특성에 관한 해석적 연구 (Numerical Analysis on Flow and Heat Transfer Characteristics in Louver Fin Heat Exchanger)

  • 한진호;박상록;김일겸;임장순
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.398-403
    • /
    • 2000
  • Numerical analysis was conducted to investigate flow and heat transfer characteristics in louver fin exchanger, which were influenced by louver pitch, fin pitch, louver angle and inlet velocity. Standard $k-\varepsilon$ turbulent modelling was used in this study, and compared with laminar modelling. As a result of this study, Nusselt number became smaller as louver pitch or fin pitch was greater. Drag coefficient became smaller as louver pitch or fin pitch was greater, but it was little affected by inlet velocity.

  • PDF

마이크로 소결 구조 채널에서의 흐름 비등 열전달 특성 연구 (Flow Boiling Heat Transfer Characteristics on Sintered Microporous Surfaces in a Mini-channel)

  • 김영환;신동환;김진섭;문우용;허재훈;이정호
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.105-110
    • /
    • 2018
  • The flow boiling heat transfer of water was experimentally investigated on plain and sintered microporous surfaces in a mini-channel. The effects of microporous coating on flow boiling heat transfer of subcooled water were investigated in a 300 mm long mini-channel with a cross section of $20{\times}10mm^2$. The test section has sufficiently long entrance length of 300 mm which provides a fully-developed flow before the channel inlet. The bottom side of the channel was heated by a copper block assembled with a high-density cartridge heater and other sides of the channel were insulated. The microporous surface was fabricated by sintering copper particles with the average particle size of $50{\mu}m$ on the top side of the copper block. Heat transfer measurement was conducted at the mass flux of $208kg/m^2s$ and the heat flux up to $500kW/m^2$. Microporous coated surface showed an earlier boiling incipience compared with plain surface regardless of the mass flux. Microporous coating were significantly attributed to local wall temperature and local heat transfer coefficient for flow boiling.

강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구 (A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection)

  • 윤찬훈;권상기;황인필;김진
    • 방사성폐기물학회지
    • /
    • 제8권3호
    • /
    • pp.189-199
    • /
    • 2010
  • 고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽입하여 암반 내부를 $90^{\circ}C$로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000~340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여름철 $7.68\;W/m^2{\cdot}K$와 겨울철 $7.24\;W/m^2{\cdot}K$의 수치를 나타냈다.

비대칭 입구조건을 갖는 정사각 막냉각홀 내부에서의 열/물질전달 및 유동 특성 (Heat/Mass Transfer and Flow Characteristics within a Film Cooling Hole of Square Cross Sections with Asymmetric Inlet Flow Condition)

  • 이동호;강승구;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.14-21
    • /
    • 2001
  • An experimental study has been conducted to investigate the heat/mass transfer characteristics within a square film cooling hole with asymmetric inlet flow conditions. The asymmetric inlet flow condition is achieved by making distances between side walls of secondary flow duct and film cooling hole different; one side wall is $2D_h$ apart from the center of film cooling hole, while the other side wall is $1.5D_h$ apart from the center of film cooling hole. The heat/mass transfer experiments for this study have been performed using a naphthalene sublimation method and the flow field has been analyzed by numerical calculation using a commercial code. Swirl flow is generated at the inlet region and the heat/mass transfer pattern with the asymmetric inlet flow condition is changed significantly from that with the symmetric condition. At the exit region, the effect of mainstream on the inside hole flow is reduced with asymmetric condition. The average heat/mass transfer coefficient is higher than that with the symmetric condition due to the swirl flow generated by the asymmetric inlet condition.

  • PDF

정사각 막냉각홀 내부에서의 열/물질전달 및 유동 특성 (II) - 비대칭 입구조건 효과 - (Heat/Mass Transfer and Flow Characteristics Within a Film Cooling Hole of Square Cross Sections (II) - Effects of Asymmetric Inlet Flow Condition -)

  • 이동호;강승구;조형희
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.937-944
    • /
    • 2002
  • An experimental study has been conducted to investigate the heat/mass transfer characteristics within a square film cooling hole with asymmetric inlet now condition. The asymmetric inlet now condition is achieved by making distances between side walls of the secondary now duct and the film cooling hole different; one side wall is $2D_h$ apart from the center of the film cooling hole, while the other side wall is $1.5D_h$ apart from the center of the film cooling hole. The heat/mass transfer experiments for this study have been performed using a naphthalene sublimation method and the now field has been analyzed by numerical calculation using a commercial code. Swirl now is generated at the inlet region and the heat/mass transfer pattem with the asymmetric inlet now condition is changed significantly from that with the symmetric condition. In the exit region, the effect of mainstream on the inside hole now is reduced with the asymmetric condition. The average heat/mass transfer coefficient is higher than that with the symmetric condition due to the swirl now generated by the asymmetric inlet condition.

Effect of Refrigeration Oil on the Condensation Heat Transfer for R-22 and R-407C Refrigerations in Microfin Tube with a U-bend

  • Cho, Keum-Nam;Tae, Sang-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.85-93
    • /
    • 2001
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-22 and R-407C in a microfin tube with a U-bend. Mineral oil and POE oil were used for R-22 and R-407C respectively. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to 400 $kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. The decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the 90$^{\circ}$position. the heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

마이크로핀관 곡관부내 대체 냉매의 응축 열전달에 미치는 냉동기유의 영향 (Effect of Refrigeration Oil on the Condensation Heat Transfer for Alternative Refrigerant in Microfin Tube with a U-bend)

  • 태상진;조금남
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.541-549
    • /
    • 2000
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-407C and R-22 in a microfin tube with a U-bend. POE oil ($74.1\;\textrm{mm}^2/s,\;40^{\circ}C$,) and mineral oil $62.5\;\textrm{mm}^2/s,\;40^{\circ}C$,) were used for R-407C and R-22 respectively Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400kg/m^{2}s sand an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the $90^{\circ}$/TEX> position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

四角리브를 갖는 傳熱面에 衝突하는 2次元 噴流의 熱傳達에 관한 硏究 (Heat Transfer of a Two-Dimensional Jet Impinging on the Wall with Transverse Repeated Ribs of Square Cross-Section)

  • 김상필;서정윤
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.214-221
    • /
    • 1987
  • 본 논문에서는 2차원충돌분류에서 사각리브(rib)를 갖는 요철형전열면에 대한 실험에 관한 것이며, 리브의 높이를 (e=5nm) 일정하게 하고 리브의 피치(p=25,35,50 nm) 변화, 노즐출구와 전열면간 거이(H/B=1~14) 및 노즐출구유속(u$_{e}$=12.30~ 18.07m/s)의 변화에 따른 전열특성을 실험적으로 구명하고 평판전열면의 경우와 비교 검토한다. 또한 스모크와이어(smoke-wire)법으로 평판 및 리브판에서의 유체의 거동 을 가시화하여 전열기구의 정성적 특성을 검토하는데 목적이 있다.

2차원(次元) 충돌분류(衝突噴流)의 열전달(熱傳達) 증진(增進)에 관(關)한 실험적(實驗的) 연구(硏究) (사각(四角) Rib폭(幅)의 효과(效果)) (Augmentation of Heat Transfer by two Dimensional Impinging Air Jet (Effect of Square Rib Width))

  • 이용화;이관석;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.350-356
    • /
    • 1988
  • The impinging air jet system is still being used in the various fields with its inherent merits, that is, the easiness in engineering application and high heat transfer coefficients at stagnation point. The purpose of this study is augmentation of heat transfer without additional power in the rectangular air jet which impinges vertically to the heating surface. As a method of passive heat transfer augmentation in a two-Dimensional impinging jet, the transverse-repeated surface roughness of square cross-section is used. This paper deals with the experimental study on the characteristics of heat transfer at the x-direction in between nozzle exit and heating surface of flat plate, and that of ribbed plate. And this study also investigates the effect of square rib widths. The integral average heat transfer coefficient of ribbed plate is about 2.2 times larger than that of flat plate.

  • PDF

마이크로핀관의 확관 전후 열전달 및 압력강하 변화 특성에 관한 연구 (Evaporation Heat Transfer and Pressure Drop in Micro-Fin Tubes Before and After Tube-Expansion)

  • 황윤욱;김민수
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.29-38
    • /
    • 2004
  • The objective of this study is to investigate the pressure drop and heat transfer characteristics of the micro-fin tubes before and after the tube-expansion process. Test tubes are single-grooved micro-fin tubes made of copper with an outer diameter of 9.52 mm before the tube-expansion. The direct heating method is applied in order to make the refrigerant evaporated in the micro-fin tubes. The test ranges of the heat flux, mass flux, and the saturation pressure are 5 to 15kW/$m^2$, 100 to 200 kg/$m^2s$ and 540 to 790 kPa, respectively. The effects of the mass flux, heat flux, and the saturation pressure of the refrigerant on the pressure drop and the heat transfer are presented for the refrigerant R22. In the test conditions of this study, the heat transfer coefficient for the micro-fin tube after the tube-expansion is about 16.5% smaller than that before the tube-expansion because the fin height of micro-fin is reduced and the fin shape becomes flatter. The micro-fin tube after the tube-expansion has about 7.7% greater average pressure drop than that before the tube-expansion process.

  • PDF