• 제목/요약/키워드: Average energy ratio

검색결과 718건 처리시간 0.024초

옥외광고용 발광조명의 야간휘도분포 분석 (Luminance Assessment of Outdoor Lighting for Advertisements at Night)

  • 신화영;이종수;김정태
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.65-72
    • /
    • 2009
  • Lighting for outdoor advertising is very common feature of building facades as they provide the information and commercial identification. As the interest of improving street beautification more widely, application of various lighting technologies has been develop for advertisement such as electric sign board and signage. Furthermore, the installation of higher sign luminance than needed has many negative consequences, including higher energy consumption and light pollution. There are now no standard for outdoor advertisements in terms of luminance, and installation of indiscreet outdoor advertisement without luminance consideration is becoming more commonplace. This study was to evaluate the luminous characteristics of outdoor advertising as a function of sign and building facade luminance, luminance ratio. Data were collected on 8 electric sign boards, 20 internally illuminated, externally illuminated, neon, and channel letter signs and 4 commercial areas. Photometric measurements were taken by CS-100(Minolta) and ProMetric-1400(Radiant Imaging) for various sign modes and sign design. Also luminance of building facades were analyzed according with CIE standard of maximum obtrusive light permitted for exterior lighting installations. The findings are as follows; (1) There were excessive luminance of electric sign boards that could affect adjacent building facade and night sky luminance. (2) Sings that are externally illuminated providing an inappropriate amount of light on to the outer surface of the sign caused higher building facade luminance and potential of unnecessary glare.

Cyclic Prefixed CI/OFDM 시스템과 단일반송파 시스템의 ABR 비교 분석 (Achievable Bit Rate Comparison of Cyclic Prefixed CI/OFDM System and Single Carrier System)

  • 장휴이;황재호;황대근;김재명
    • 한국위성정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.6-16
    • /
    • 2010
  • Since OFDM system suffers from high peak-to average power ratio(PAPR) drawbacks, more energy has been converted to seek for a new substitutable system which can maintain OFDM system's inherent virtues while avoid its defects. Consequently, a new multicarrier system called as CI/OFDM system has been proposed which applied carrier interferometry(CI) code to OFDM system. Due to its low PAPR advantage and orthogonal property, it has received more and more attention. Simultaneously, an old technique called single carrier(SC) system has retaken its attractions for the same purposes. This paper analyzes two cyclic prefixed transmission schemes variants of OFDM system: 1.carrier interferometry-Orthogonal Frequency-Division Multiplexing (CI/OFDM); 2. Cyclic prefixed single carrie(CP-SC) with frequency domain equalization. We compare the achievable bit rate transmission of the two systems in terms of signal to noise ratio(SNR) by mathematical derivation. We demonstrated that CI/OFDM achieves a bit higher transmission bit rate to that of the CP-SC with frequency domain equalizer.

Analytical solution and experimental study of membrane penetration in triaxial test

  • Ji, Enyue;Zhu, Jungao;Chen, Shengshui;Jin, Wei
    • Geomechanics and Engineering
    • /
    • 제13권6호
    • /
    • pp.1027-1044
    • /
    • 2017
  • Membrane penetration is the most important factor influencing the measurement of volume change for triaxial consolidated-drained shear test for coarse-grained soil. The effective pressure p, average particle size $d_{50}$, thickness $t_m$ and elastic modulus $E_m$ of membrane, contact area between membrane and soil $A_m$ as well as the initial void ratio e are the major factors influencing membrane penetration. According to the membrane deformation model given by Kramer and Sivaneswaran, an analytical solution of the membrane penetration considering the initial void ratio is deduced using the energy conservation law. The basic equations from theory of plates and shells and the elastic mechanics are employed during the derivation. To verify the presented solution, isotropic consolidation tests of a coarse-grained soil are performed by using the method of embedding different diameter of iron rods in the triaxial samples, and volume changes due to membrane penetration are obtained. The predictions from presented solution and previous analytical solutions are compared with the test results. It is found that the prediction from presented analytical solution agrees well with the test results.

Fragility assessment of shear walls coupled with buckling restrained braces subjected to near-field earthquakes

  • Beiraghi, Hamid
    • Steel and Composite Structures
    • /
    • 제33권3호
    • /
    • pp.389-402
    • /
    • 2019
  • Reinforced concrete walls and buckling restrained braces are effective structural elements that are used to resist seismic loads. In this paper, the behavior of the reinforced concrete walls coupled with buckling restrained braces is investigated. In such a system, there is not any conventional reinforced concrete coupling beam. The coupling action is provided only by buckling restrained braces that dissipate energy and also cause coupling forces in the wall piers. The studied structures are 10-, 20- and 30-story ones designed according to the ASCE, ACI-318 and AISC codes. Wall nonlinear model is then prepared using the fiber elements in PERFORM-3D software. The responses of the systems subjected to the forward directivity near-fault (NF) and ordinary far-fault (FF) ground motions at maximum considered earthquake (MCE) level are studied. The seismic responses of the structures corresponding to the inter-story drift demand, curvature ductility of wall piers, and coupling ratio of the walls are compared. On average, the results show that the inter-story drift ratio for the examined systems subjected to the far-fault events at MCE level is less than allowable value of 3%. Besides, incremental dynamic analysis is used to examine the considered systems. Results of studied systems show that, the taller the structures, the higher the probability of their collapse. Also, for a certain peak ground acceleration of 1 g, the probability of collapse under NF records is more than twice this probability under FF records.

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

Chemical Properties of the Individual Asian Dust Particles Clarified by Micro-PIXE Analytical System

  • Ma, Chang-Jin;Kang, Gong-Unn;Kasahara, Mikio;Tohno, Susumu
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권3호
    • /
    • pp.154-161
    • /
    • 2014
  • The present study was undertaken to evaluate the chemical characteristics of Asian dust (hereafter called "AD") particles with the aid of the most advanced micro-PIXE (Particle-induced X-ray emission) analytical technique. To this end, size-selected particles were sampled on a rural peninsula of Korea (Byunsan, 35.37N; 126.27E) during AD and non-AD periods in 2004. The coarse particle (> $2{\mu}m$) number density during an AD event were 170 times higher than those of the non-AD counterpart. The average net-count of silica in individual particles collected on AD event was roughly 11 times higher than that of non-AD counterpart. The X-ray net-counts of trace elements (Zn, Co, Mn, and V) were also considerably high in AD relative to the non-AD day. Particle classification based on the inter ratio analysis of elemental net-count suggests that a large portion of the coarse particles collected during AD event underwent chemical transformation to a certain degree. The visual interpretation of micro-PIXE elemental maps and elemental localization data in and/or on individual AD particles clarified the internal mixture of AD particles with sea-salt and artificial metallic particles.

DLTS 법(法)에 의한 Laser CVD SiON 막(膜)-Si 계(系)의 계면(界面) 특성(特性) (Laser CVD SiON-Si interface investigation by DLTS)

  • 천영일;김상욱;이승환;박지순;박근영;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.237-240
    • /
    • 1991
  • In this paper, silicon oxynitride(SiON) films were chemically deposited by 193 nm Excimer laser irradiated parallel to the substrate. the laser pulse energy was 80 mJ, repetetion rate was 80 Hz and the laser average power was 6.4 watt, the gas ratio of $N_2O/NH_3$ was 0.75, the substrate temperature was $300^{\circ}C$, and the chamber pressure was 2 torr. And then, the interface state density($N_{ss}$) was characterized by DLTS(Deep Level Transient Spectroscopy). In addition, the capture cross section($\sigma$) and activation energy(${\Delta}E$) was also obtained. The resulting Nss values were $5.5{\times}10^{10}-3.2{\times}10^{11}(eV^{-1}cm^{-2})$, $\sigma$ was $6.64{\times}10^{-20}-2.114{\times}10^{-17}(cm^2)$, the ${\Delta}E$ of two peaks were $8.93{\times}10^{-2}$(eV), 0.375(eV).

  • PDF

강원지역 영양사의 영양지식, 식생활태도 및 영양소 섭취실태 (Nutrition knowledge, Dietary Attitudes and Nutrient Intakes of Dietitians Living in Kangwon Area)

  • 윤현숙
    • 한국식생활문화학회지
    • /
    • 제14권4호
    • /
    • pp.319-331
    • /
    • 1999
  • This nutritional survey was conducted in February 25, 1999, in order to investigate the nutritional knowledge, dietary attitudes and nutrient intakes of dietitians living in Kangwon area. Subjects consisted of 250 dietitians, with 184 in school food service, 14 in hospital food service and 52 in institution food service. Data were analyzed for frequencies, means, t-test, $x^2$-test, ANOVA and Pearson correlation using SPSS PC Package. The results obtained are summarized as follows: The average nutritional knowledge score was 10.15 out of possible 15 points, and dietary attitude score was 67.93 out of 100 points. The correlation between nutritional knowledge score and dietary attitude score was lowly(${\gamma}=-0.25$). Nutrients consumed below the Korean RDA were energy (78.77%), Ca(90.5%), Fe(83.70%) and nutrients consumed above the Korean RDA were protein(110.83%), P(140.21%), vit.A(163.94%), $vit.B_2$(126.37%), niacin(121.12%) and vit C(231.86%). Carbohydrate, protein and fat ratio on energy composition was 63%:17%:20%. The nutrient density among 3 groups of dietitian was not significantly different.

  • PDF

부틸메타크릴레이트의 환경친화적인 광중합 및 열분해특성 (A Characteristics of Environmental Fraternitive Photopolymerization and Thermal Degradation on Butyl Methacrylate)

  • 최재욱;설수덕;이내우
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.45-51
    • /
    • 2002
  • This study is the series of photopolymerization on alkyl methacrylate(AMA) to continue further research. The objective of this work is to investigate the environmental fraternitive characteristics of photopolymerization kinetics on n-Buthyl methacrylate(BMA) and comparing the decomposition behavior to other AMA. The experiment was done in aqueous solution under the influence of photo-initiator concentration$(0.05{\sim}0.25mol/l)$, light intensity$(5000{\sim}9000{\mu}J/cm^{2})$ and monomer concentration$(2.0{\sim}6.0mol/l)$. n-BMA was polymerized to high conversion ratio using hydrogen $peroxide(H_{2}O_{2})$, and the kinetics model we have obtained is as follows. $R_{p}=K_{p}[S]^{0.24}[M]^{0.33}[L]^{153}exp^{(27.19/RT)}$ The differential method of thermogravimetric analysis(Friedman method) was used to obtain value of activation energy on decomposition reaction. The average value of it was 27.5Kcal/mol.

EFFECT OF FUEL STRATIFICATION ON INITIAL FLAME DEVELOPMENT: PART 1-WITHOUT SWIRL

  • Ohm, I.Y.;Park, C.J.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.519-526
    • /
    • 2006
  • For investigating the effect of fuel stratification on flame propagation, initial flame development and propagation were visualized under different axially stratified states in a port injection SI engine. Stratification was controlled by the combination of the port swirl ratio and injection timing. Experiments were performed in an optical single cylinder engine modified from a production engine and images were captured through the quartz window mounted in the piston by an intensified CCD camera. Firstly in this paper, the characteristics under no port-generated swirl condition, i.e. normal conventional case was studied. Under various stratified conditions, flame images were captured at the pre-set crank angles. These were averaged and processed to characterize the flames propagation. The flame stability was estimated by the weighted average of flame area and luminosity. The stability was also evaluated through the standard deviation of flame area and propagation distance, and mean absolute deviation of propagating direction. Results show that stratification state according to injection timing do not affect on the direction of flame propagation. The flame development and the initial flame stability are strongly dependent on the stratified conditions and the initial flame stability is closely related to the engine stability and lean misfire limit.