• Title/Summary/Keyword: Average compressive strength

Search Result 280, Processing Time 0.031 seconds

Physical Properties of Insulating Composite Materials Using Natural Cellulose and Porous Ceramic Balls as a Core Materials (천연섬유질과 다공성 세라믹볼을 심재로 사용한 복합단열재의 물성)

  • Hwang, Eui-Hwan;Cho, Soung-Jun;Kim, Jin-Man
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.501-507
    • /
    • 2011
  • To develop environmental-friendly insulating composite materials, natural cellulose and porous ceramic balls were used as core materials and activated Hwangtoh was used as a binder. Various specimens were prepared with different water/binder ratios and core material/binder ratios. The physical properties of these specimens were then investigated through compressive strengths, flexural strengths, absorption test, hot water resistance test, pore analysis, thermal conductivity, and observation of micro-structures using scanning electron microscope. Results showed that the maximum compressive strength varied appreciably with the water/binder ratios and core material/binder ratios, but the flexural strength increased with the core material/binder ratios regardless of water/binder ratios. The compressive strength and the flexural strength measured after the hot water resistance test decreased remarkably compared to those measured before test. The pore analysis measured after the hot water resistance test showed that total pore volume, porosity and average pore diameter decreased, while bulk density increased by the acceleration of hydration reaction of binder in the hot water. The thermal conductivity decreased gradually with an increase of core material/binder ratios. It can be evaluated that the composite insulation materials having good insulating properties and mechanical strengths can be used in the field.

Optimum Mix Proportion of Latex Modified Repair Mortar for Agricultural Concrete Structures (농업용 콘크리트 구조물을 위한 라텍스 개질 보수용 모르타르의 적정 배합비 도출)

  • Won, Jong-Pil;Lee, Jae-Young;Park, Chan-Gi;Park, Seong-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.2
    • /
    • pp.37-46
    • /
    • 2007
  • The service life of agricultural concrete structures is designed in about 30 to 100 years, but actual service lift is estimated in an average 18 years. Therefore, as the service life of the agricultural concrete structures increases, necessity of repair by aging from various environment condition exposure increases. This study was to determinate the optimum mix proportion of latex modified repair mortar and to improve the durability performance of agricultural concrete structures. The physical and mechanical tests of latex modified repair mortar were performed. Tests of flow, compressive strength, flexural strength and bond strength tests were conducted. Test results show that the optimum nex proportion of latex modified repair mortar, when used in 5% latex volume fraction (weight of cement), 1.5% antifoaming agent (weight of latex), 0.2% PVA fiber volume fraction, 1:2 (binder-sand ratio), 10% silica fume replacement ratio (weight of cement), could result in best performance for the repair of agricultural concrete structures.

An artificial intelligence-based design model for circular CFST stub columns under axial load

  • Ipek, Suleyman;Erdogan, Aysegul;Guneyisi, Esra Mete
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.119-139
    • /
    • 2022
  • This paper aims to use the artificial intelligence approach to develop a new model for predicting the ultimate axial strength of the circular concrete-filled steel tubular (CFST) stub columns. For this, the results of 314 experimentally tested circular CFST stub columns were employed in the generation of the design model. Since the influence of the column diameter, steel tube thickness, concrete compressive strength, steel tube yield strength, and column length on the ultimate axial strengths of columns were investigated in these experimental studies, here, in the development of the design model, these variables were taken into account as input parameters. The model was developed using the backpropagation algorithm named Bayesian Regularization. The accuracy, reliability, and consistency of the developed model were evaluated statistically, and also the design formulae given in the codes (EC4, ACI, AS, AIJ, and AISC) and the previous empirical formulations proposed by other researchers were used for the validation and comparison purposes. Based on this evaluation, it can be expressed that the developed design model has a strong and reliable prediction performance with a considerably high coefficient of determination (R-squared) value of 0.9994 and a low average percent error of 4.61. Besides, the sensitivity of the developed model was also monitored in terms of dimensional properties of columns and mechanical characteristics of materials. As a consequence, it can be stated that for the design of the ultimate axial capacity of the circular CFST stub columns, a novel artificial intelligence-based design model with a good and robust prediction performance was proposed herein.

A Fundamental Study on Evaluation of Web Crippling Strength of Corroded H-Beams (부식 H형 강재의 복부좌굴강도 추정에 관한 기초적 연구)

  • Kim, In-Tae;Shin, Chang-Hee;Cheung, Ji-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.421-433
    • /
    • 2010
  • The most typical deterioration of steel structures is corrosion damage. However, a method to evaluate residual load-carrying capacity of corroded steel structures is not yet established. It is difficult to check current serviceability and safety of the structures. In this study, compressive tests and finite element analyses were conducted on H-beams with corroded web. Then, the effect of corrosion damage on web crippling strength and evaluation methods of the web crippling strength are studied. Based on the tests, 4 H-beam specimens used in a subway construction site and 9 H-beam specimens with different web-thickness and damaged-height underwent compression-tests. To consider loading and supporting areas in the site, compressive loading was applied in the entire region of the upper and bottom flange in 5 H-beam specimens and applied partially on the regions of the upper and bottom flange in 8 specimens. The finite element analysis of 38 parametric model specimens simulating different corrosion damages was also carried out. From experimental and analytical results, the relationships between corrosion damages in the web and residual web crippling strength are presented. Factors web crippling strength was reduced are formulated by using residual average thickness and the standard deviation of the corroded web thickness. Also, a simple evaluation method of residual web crippling strength was proposed.

Exploiting the Potentials of Rice Husk Ash as Supplement in Cement for Construction in Nigeria

  • Akindahunsi, Akindehinde Ayotunde;Alade, Oluwotosin
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.1
    • /
    • pp.3-8
    • /
    • 2010
  • This paper present the results of investigation on the use of rice husk ash as a partial substitute for cement in construction. One hundred and eighty specimens of concrete cubes were cast. 0, 5, 10, 15, and 20% partial replacement of cement with rice husk ash were carried at 1:2:4 mixes by weight with 0.60, 0.65, 0.70 water/cement ratio. The results indicated that compressive strengths of cubes at 0.6, water/cement were higher than 0.65 and 0.70. Also 5% partial replacement cement with rice husk ash at $28^{th}$ day average compressive strength value of $25.4\;N/mm^2$ compared well with 0% partial replacement of cement with rice husk ash of $26.28\;N/mm^2$. This shows that at 5% partial replacement of cement with rice husk ash can be used for structural concrete and at 15% replacement or more it can be used for non - structural construction works or light weight concrete construction. The cost analysis shows substantial amount of savings for the country.

A Study on the Fundamental Properties of Ultra Rapid Hardening Mortar using Coal-Ash (잔골재 대체재로서 석탄회를 이용한 초속경 보수모르타르의 기초적 특성에 관한 연구)

  • Lee, Gun-Cheol;Oh, Dong-Uk;Kim, Young-Geun;Cho, Chung-Ki
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.128-135
    • /
    • 2011
  • In this study, in order to develop ultra rapid hardening mortar(URHM) for tunnel repairs using bottom ash of low recycle ratio and Admixture as Eco concept, fundamental properties of URHM on temperature condition of construction field were performed. Test result, URHM of three types for fluidity and setting time were as in the following : B > C > A. Those for low temperatures were later than the standard condition. Compressive, bending and bond strength were similar with three types as follow. In compressive strength, initial strength of the low were smaller than the standard but the low in the long-term were similar with the standard. On the contrary to this, bending strength were similar in initial strength but the low in the long-term were smaller than the standard. The low in bond strength was average 35% less than the standard. Length changes was as in the following : A > C > B. the low is two times much as the standard but the case using blast furnace slag particles noticeably reduced length changes. Water absorption coefficient and water vapor resistance were as in the following : C > A > B. In case of URHM added bottom ash, water absorption coefficient and water vapor resistance were increased because bottom ash is porous material.

  • PDF

Evaluation of Strength and Chloride Diffusion in Concrete with FA Considering Temperature Effect (FA를 혼입한 콘크리트의 온도 영향을 고려한 강도 및 염화물 확산성 평가)

  • Keun-Hyeok Yang;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.62-69
    • /
    • 2023
  • For the nuclear power concrete plant structures in the UAE, it is necessary to consider the deterioration from high sulfate ions in the atmosphere and high chloride ions from the coast. In this study, two strength grade concrete mixture (40 MPa and 27 MPa) and two curing/diffusion temperatures (20 ℃ and 50 ℃) were considered for evaluating the temperature effects on diffusion and strength due to high average temperature above 38 ℃ a year in UAE. When the initial curing temperature was high, the compressive strength increased in high-temperature curing to 7 days, but the strength slightly increased in the 20 ℃ curing condition at 28 days. Regarding diffusion test, unlike the compressive test results, reduced chloride diffusion coefficients were evaluated both in 40 MPa and 27 MPa grade at 28 days. In the case of 91 days of curing, an increase in diffusivity due to high temperature and a decrease in diffusivity due to age effect occur simultaneously. Compared to the results of the curing and diffusion tests at 20 ℃ and 28 days, when the curing and diffusion tests were conducted at 50 ℃ in 91 days, the diffusion coefficients decreased to 76.2 % in 40 MPa grade and 85.4 % in 37 MPa grade with increasing curing period, respectively.

Behavior of 550MPa 43mm Hooked Bars Embedded in Beam-Column Joints (보-기둥 접합부에 정착된 550 MPa 43 mm 갈고리철근의 거동)

  • Bae, Min-Seo;Chun, Sung-chul;Kim, Mun-Gil
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.611-620
    • /
    • 2016
  • In the construction of nuclear power plants, only 420 MPa reinforcing bars are allowed and, therefore, so many large-diameter bars are placed, which results in steel congestion. Consequently, re-bar works are difficult and the quality of RC structures may be deteriorated. To solve the steel congestion, 550 MPa bars are necessary. Among many items for verifying structural performance of reinforced concrete with 550 MPa bars, the 43 mm hooked bars are examined in this study. All specimens failed by side-face blowout and the side cover explosively spalled at maximum loads. The bar force was initially transferred to the concrete primarily by bond along a straight portion. At the one third of maximum load, the bond reached a peak capacity and began to decline, while the hook bearing component rose rapidly. At failure, most load was resisted by the hook bearing. For confined specimens with hoops, the average value of test-to-prediction ratios by KCI code is 1.45. The modification factor of confining reinforcement which was not allowed for larger than 35 mm bars can be applied to 43 mm hooked bars. For specimens with 70 MPa concrete, the average value of test-to-prediction ratios by KCI code is 1.0 which is less than the values of the other specimens. The effects of concrete compressive strength should be reduced. An equation to predict anchorage capacity of hooked bars was developed from regression analysis including the effects of compressive strength of concrete, embedment length, side cover thickness, and transverse reinforcement index.

Estimation of R-value and Uniaxial Compressive Strength of Rocks around the King Sejong Station, Barton Peninsula, Antarctica from SilverSchmidt Q-value (실버슈미트 Q값으로부터 남극 바톤반도 세종과학기지 주변 암석의 R값 및 일축압축강도 추정)

  • Lim, Hyoun-Soo;Jang, Bo-An;Kim, Jung-Han;Kang, Seong-Seung
    • Tunnel and Underground Space
    • /
    • v.25 no.2
    • /
    • pp.199-209
    • /
    • 2015
  • The rebound hardness test using the SilverSchmidt hammer was performed for diorite, granodiorite, and andesite exposed around the King Sejong Station, Barton peninsula. Then, the R-value and uniaxial compressive strength (UCS) of these rocks were estimated from the Q-values which were obtained from the SilverSchmidt hammer. The Q-value of diorite was distributed in the range from 67.0 to 89.5, granodiorite of the range from 57.5 to 89.0, and andesite of the range from 58.0 to 76.5. The average Q-values of diorite, granodiorite, and andesite were 76.0, 72.0, and 67.0, respectively. The converted UCS of diorite was distributed in the range from 118 to 195 MPa, granodiorite of the range from 91 to 193 MPa, and andesite of the range from 92 to 148 MPa. The average UCS of diorite, granodiorite, and andesite were 147, 136, and 117 MPa, respectively. The converted R-value of diorite was distributed in the range from 53.0 to 72.2, granodiorite of the range from 45.4 to 71.8, and andesite of the range from 45.8 to 60.9. The average Q-values of diorite, granodiorite, and andesite were 60.0, 58.0, and 53.0, respectively. The R-value was represented approximately 20% lower than the Q-value. In conclusion, it will be possibile that the R-value and UCS of rocks under the extreme area from the SilverSchmidt Q-value are evaluated.

Characteristics of Solidification/Carbonation in the Heavy-Metal-Contaminated Sediment Treated by MgO-Based Binder (MgO 기반 고화제를 이용하여 처리한 중금속 오염 준설토의 고형화/탄산염화 특성)

  • Hwang, Kyung-Yup;Seo, Jeong-Yun;Phan, Hoang Quang Huy;Ahn, Jun-Young;Hwang, Inseong
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.102-111
    • /
    • 2013
  • A novel MgO-based binder was developed and applied to treat the anoxic sediment that was collected from Seonakdong river, Korea and was contaminated with heavy metals. The treated sediment was evaluated by measuring compressive strength, expansion, leaching of heavy metals and storage characteristics for $CO_2$. Initially, an optimal blending ratio of lime (L)/fly ash (FA)/blast furnace slag (BFS) that was to be mixed with MgO was screened to be $L_{0.3}-FA_{0.1}-BFS_{0.6}$. Long-term strengths of the sediments that were treated by various mixtures of MgO and $L_{0.3}-FA_{0.1}-BFS_{0.6}$ were then evaluated and the blending ratios between 4 : 6 and 6 : 4 were found optimal, which yielded a compressive strength of 4.09 MPa. On this basis, the optimal MgO-based binder was selected to be a 5 : 5 mixture of MgO and $L_{0.3}-FA_{0.1}-BFS_{0.6}$. The good performance of the MgO-based binder was believed to be due to the formation of Mg $(OH)_2$, which filled the micropores and also increased the density of the solidified matrices. The MgO-based binder exhibited an average stabilizing capacities for heavy metals of 92.9%, which was similar to or higher than that of Portland cement. It was found that 69.1 kg of carbon dioxide could be sequestrated after 365 days of curing when treating a ton of anoxic sediments.