• Title/Summary/Keyword: Average Value

Search Result 6,812, Processing Time 0.038 seconds

Effect of Silicate Mineral Filtered Water and Silicate Mineral Additive on Growth Performance and Pork Quality (규산염 광물질로 정수된 급이수 및 사료내 규산엽광물질 첨가제의 급여가 돼지의 성장능력 및 돈육의 품질에 미치는 영향)

  • Kong, C.S.;Ju, W.S.;Kil, D.Y.;Lim, J.S.;Yun, M.S.;Kim, Y.Y.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.743-752
    • /
    • 2004
  • This experiment was conducted to investigate the effect of filtered water with silicate minerals on growth performance and pork quality. A total of 64 pigs were allotted at 37.95 kg body weight to 4 treatments in a randomized complete block(RCB) design. Each treatment had 4 replicates and treatments were I) Con(basaI diet). 2) Si-I(consumed silicate mineral filtered water and silicate mineral additive during 4 weeks before market weight), 3) Si-Il( consumed silicate mineral filtered water and silicate mineral additive during 8 weeks before market weight) and 4) Si-I1I(consumed silicate mineral filtered water and silicate mineral additive during 12 weeks before market weight). Silicate complex was added at 0.8% to basal diet. All pigs were allowed to feed and water ad libitum for 12 weeks. During last 4 weeks, average daily gain(ADG) in Si-Il and Si-III group was higher than that in Si-I group(P < 0.05). However overall experimental period, there were no significant differences in growth performance among all treatments. Acceptability of cooked pork at 7th day after slaughter in Si-lII group was higher than that in Con group(P < 0.05). The value of pH of fresh pork at 6 hours after slaughter was lower in Si-I1I group than that in Con group(P < 0.05). TBA values of fresh pork at 14th day after slaughter were lower in Si-II and Si-III groups than Con group(P < 0.05). These results demonstrated that pork quality could be improved when pigs consumed both silicate mineral and silicate mineral filtered water. However, growth performance was not improved by the consumption of silicate mineral filtered water and silicate mineral.

Studies on the Time Distribution of Heavy Storms (暴雨의 時間的 分布에 關한 硏究)

  • Lee, Keun-Hoo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.2
    • /
    • pp.69-84
    • /
    • 1984
  • This study was carried out to investigate the time distribution of single storms and to establish the model of storm patterns in korea. Rainfall recording charts collected from 42 metheorological stations covering the Korean peninsula were analyzed. A single storm was defined as a rain period seperated from preceding and succeeding rainfall by 6 hours and more. Among the defined single storms, 1199 storms exceeding total rainfall of 80 mm were qualified for the study. Storm patterns were cklassified by quartile classification method and the relationship between cummulative percent of rainfalls and cummulative storm time was established for each quartile storm group. Time distribution models for each stations were prepared through the various analytical and inferential procedures. Obtained results are summarized as follows: 1. The percentile frequency of quartile storms for the first to the fourth quartile were 22.0%, 26.5%, 28.9% and 22.6%, respectively. The large variation of percentile frequency was show between the same quartile storms. The advanced type storm pattern was predominant in the west coastal type storm patterns predominantly when compared to the single storms with small total rainfalls. 3. The single storms with long storm durations tended to show delayed type storm patterns predominantly when compared to the single storms with short storm durations. 4. The percentile time distribution of quartile storms for 42 rin gaging stations was estimated. Large variations were observed between the percentiles of time distributions of different stations. 5. No significant differences were generally found between the time distribution of rainfalls with greater total rainfall and with less total rainfall. This fact suggests that the size of the total rainfall of single storms was not the main factor affecting the time distribution of heavy storms. 6. Also, no significant difference were found between the time distribution of rainfalls with long duration and with short duration. The fact indicates that the storm duration was no the main factor affecting the time distribution of heavy storms. 7. In Korea, among all single storms, 39.0% show 80 to 100mm of total rainfall which stands for the mode of the frequency distribution of total rainfalls. The median value of rainfalls for all single storms from the 42 stations was 108mm. The shape of the frequency distribution of total rainfalls showed right skewed features. No significant differences were shown in the shape of distribution histograms for total rainfall of quartile storms. The mode of rainfalls for the advanced type quartile storms was 80~100mm and their frequencies were 39~43% for respective quartiles. For the delayed type quartile storms, the mode was 80~100mm and their frequencies were 36!38%. 8. In Korea, 29% of all single storms show 720 to 1080 minutes of storm durations which was the highest frequency in the frequency distribution of storm durations. The median of the storm duration for all single storms form 42 stations was 1026 minutes. The shape of the frequency distribution was right skewed feature. For the advanced type storms, the higher frequency of occurrence was shown by the single storms with short durations, whereas for the delayed type quartile storms, the higher frequency was shown gy the long duration single storms. 9. The total rainfall of single storms was positively correlated to storm durations in all the stations throughout the nation. This fact was also true for most of the quartile storms. 10. The third order polynomial regression models were established for estimating the time distribution of quartile storms at different stations. The model test by relative error method resulted good agreements between estimated and observed values with the relative error of less than 0.10 in average.

  • PDF

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Study of Factors Affecting to Discrepancy between Self-Reported and Body Weight and Height (신장(身長) 및 체중(體重)의 실측치(實測値)와 상용치간(常用値間)의 오차(誤差)에 영향을 미치는 인자(因子))

  • Han, Gu-Wung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.59-65
    • /
    • 1983
  • Screening data from preplacement and periodic examination in Gu Mi Industrial Estate from May, 1983 to June, 1983 provide an opportunity to evaluate the accuracy of self-reported height and weight. The data for men and women were analyzed separated for effects of age, marrital status, educational level, employment status, measured height, measured weight and relative weight (percent of ideal body weight). The mean percent discrepancy from self-reported and measured height was analysed by cross-tubulation, P. value for analysis of variance and multiple correlation analysis in men and women. It is clear from the data that self-reported height and weigt differ from the quantities in systemic ways. But the magnitude of misreporting is very small on average except for weight in women. Whereas height tend to be over-reported, weight is under-reported in women but over-reported in men. Weight was accuracte for age group 20-29 years in men and age group over 40 year in women and over-reporting of weight increased with age in men and under-reporting of weight decreased with age in women. Weight was accurate in 60-64kg group in men and under 50kg group in women and under-stating of weight increased with weight in men and women. Weight was the most accurate in 100-109 percent relative weight group in men and in 90-99 percent relative weight group in women and under-stating of weight increased with relative weight and over-stating decreased with relative weight and over-stating decreased with relative weight in men and women. Height was the most accurate for group of primary school and except group of primary school, accuracy of height increased with educational level in men and women. In height, the highest measured height groups (over than 175cm measured height in men and over than 165cm measured height in women) were the most accurate and of over-reporting of height decreased with measured height. Single variable regression analysis and ANOVAs showed age(P<0.003), measured weight(P<0.0001) relative weight(P<0.0001), educational level(P<0.0005) and employment status(P<0.0007) to be significantly related to ${\Delta}WT$ in women and measured height(P<0.0001), educational level(P<0.03) and marrital status (P<0.03) to be significantly related to ${\Delta}WT$ in men. The women were more sensitive about her body weight than height.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Occurrence of Mycotoxins in Korean Grains and Their Simultaneous Analysis (한국산 곡류에서의 곰팡이독소 오염현황 및 동시분석)

  • Kim, Dong-Ho;Jang, Han-Sub;Choi, Gyu-Il;Kim, Hyun-Jung;Kim, Ho-Jin;Kim, Hyo-Lin;Cho, Hyun-Jung;Lee, Chan
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.111-119
    • /
    • 2013
  • Eleven mycotoxins, including aflatoxins, ochratoxin A, fumonisins, zearalenone, T-2 toxin, deoxynivalenol, and HT-2 toxin, were analyzed simultaneously in rice, barley, and maize produced in 2011 by liquid chromatography coupled with triple quadrupole mass spectrometry (LC/MS/MS). Limits of detection (LOD) are 0.2 ${\mu}g/kg$ for aflatoxin $B_1$, and $G_1$, 0.3 ${\mu}g/kg$ for aflatoxins $B_2$, and $G_2$, 0.1 ${\mu}g/kg$ for ochratoxin, fumonisins, zearalenone, and T-2 toxin and 3.0 ${\mu}g/kg$ for deoxynivalenol and HT-2 toxin. Limits of quantification (LOQ) were 0.6 ${\mu}g/kg$ for aflatoxins $B_1$, and $G_1$, 0.9 ${\mu}g/kg$ for aflatoxins $B_2$, and $G_2$, 0.3 ${\mu}g/kg$ for ochratoxin, fumonisins, zearalenone, and T-2 toxin and 10.0 ${\mu}g/kg$ for deoxynivalenol and HT-2 toxin. Recoveries for 11 mycotoxins ranged from 70.45 to 111.11%. Fumonisins, deoxynivalenol, and zaeralenone were detected from 0.9 to 334.0 ${\mu}g/kg$ in the polished rice, barley and raw corn cultivated in Korea. Other mycotoxins were not detected. Deoxynivalenol contamination was mainly found in barley (24 out of 43 samples) and the average value in positive samples was 113.30 ${\mu}g/kg$.

A Fundamental Study on the Types of Ship and the Steerage of Purse Seiners (巾着網漁船의 船型과 操船의 基礎的 硏究)

  • 김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.1
    • /
    • pp.13-24
    • /
    • 1994
  • Purse seiner detects a fish school navigating in full speed with the aid of fish finder, sonar, helicopter, etc., and casts a net quickly to enclose the fish school in purse seine net according to the movement of the fish school, wind, and current. At this moment, if the time of casting a net, direction, speed, and turning circle are net suitable, it is unavoidable to lose fish school founded with hard efforts and we only consume our efforts of casting and hauling the net. Therefore, in order to enclose the fish school to enhance the amount of fish for each casting, the author investigated the type of ships equipped with purse seiners and examined maneuvering tests so that we provide some basic information to figure out the ability of steerage correctly. The results obtained are summarized as follows: 1. Block coefficients of pelagic tuna purse seiners with gross tonnage between 500 and 1500 tons are recorded between 0.50 and 0.55 which are greater than those of off shore purse seiners recorded as between 0.44 and 0.54 and less than those of various cargo ships recorded as between 0.56 and 0.84. 2. L/B, L/D, B/D, B/T, and T/D of the class of gross tonnage between 75 and 130 tons are respectively 4.49, 11.00, 2.45, 2.85 and 0.86 as their average and those of the class of between 500 and 1500 tons are 4.89, 10.53, 2.15, 2.73 and 0.75 respectively, which are quite different from those of various cargo ships recorded as 6.0~7.5, 11.0~12.0, 1.6~2.0, 2.2~2.8 and 0.65~0.75 respectively. 3. Rudder area ratio of purse seiners of the class of between 75 and 130 tons is 1/24~1/31 and that of the clase of between 500 and 1500 tons is 1/36~1/42 which is greater than that of various cargo ships recorded as 1.45~1.75. 4. On speed-length ratio of purse seiners. 111 Dong-a has the biggest value 2.94 the class of 130 tons has 2.52 the class of between 75 and 100 tons has 2.30~2.35 and the class of between 500 and 1500 tons has 1.99~2.05. 5. Turning circle of stern trawlers Pusan 404 and Haelim 3 are measured as below according to rudder angles 5$^{\circ}$, 15$^{\circ}$, 25$^{\circ}$ and 35$^{\circ}$ respectively. Advances are 11.3~13.6, 6.0~7.1, 3.6~4.8 and 2.5~3.5 times of LPP respectively. Tactial diameters are 15.2~18.6, 6.9~8.0, 4.2~4.9 and 2.9~3.5 times of LPP. Purse seiner 111 Dong-a with rudder angle 35$^{\circ}$ has a good yaw with quick responsibility since its advance is 2.2~2.3 times of LPP and since its tactial diameter is 2.0~2.1 times of LPP. 6. In full ahead going of purse seiner 111 Dong-a, it takes about 2 minutes and 10.6 times of LPP from the reverse turning its engine into full astern to the ship speed 0. In its full astern going, it takes about 1 minute and 5.1 times of LPP from the reverse turning its engine into full ahead to the ship speed 0. In its full ahead going, it takes about 2 minutes and 50 seconds and 12.3 times of LPP from stopping its engine to the dead slow ahead speed 3.2 knots.

  • PDF