• 제목/요약/키워드: Average Filter

검색결과 902건 처리시간 0.03초

Moving Average를 이용한 전압강하보상 알고리즘에 관한 연구 (A Study of Voltage Drop Compensation Algorithm using Moving Average)

  • 김성환;김진선;김영조;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1202-1204
    • /
    • 2004
  • This paper propose the control algorithm for improving the power quality through the voltage compensation when source voltage is dropped. The algorithm signified occurrence of voltage drop in source voltage of each phase storing source voltage for two cycles using the concept of moving average and using the source voltage of last half cycle. If there are voltage drops in the source voltages, series active power filter compensates the differences between reference waveform and source voltage waveform. Therefore, voltage drop is compensated. It proposed series active power filter of three phases three lines to apply to the proposed algorithm and the presented experiment results verified logicality and effectiveness of the proposed algorithm.

  • PDF

Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량 (Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis)

  • 김계선;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.347-353
    • /
    • 2015
  • 디지털 흉부단층합성법 검사에서 부가필터 사용에 따른 환자의 선량과 화질의 특성을 비교해보고자 하였다. 부가필터의 종류는 구리, 알루미늄, 니켈을 사용하였으며, 이 때 각 각의 부가필터에 따른 유효선량, 면적선량을 측정해 보았고, 화질의 물리적 평가방법으로 signal to noise ratio (SNR)과 contrast to noise ratio (CNR)을, 시각적 평가방법으로 contrast detail (CD) phantom을 이용한 CD 곡선을 비교하였다. 그 결과 부가필터별 조사선량이 비슷한 두께는 0.3 mmCu, 3 mmAl, 0.3 mmNi 였으며 부가필터를 사용하지 않았을 때 보다 조사선량 값이 평균 33.1% 감소하였다. 각 필터 별 dose area product (DAP) 선량값을 측정한 결과 Ni를 사용하였을 때 선량이 72.9% 감소하여 가장 낮았으며, 필터별 DAP 값은 통계적으로 유의한 차이를 보였다(p<0.01). 유효선량은 Ni를 사용하였을 때 가장 낮은 선량 값을 보였고, 필터를 사용하지 않았을 때 0.102 mSv에 비해 48.0% 감소하였다. CD phantom에 의한 시각적 화질평가에서는 각 필터별로 비슷한 양상을 나타냈으며, 3가지 부가필터를 사용 하였을 때 S NR과 CNR은 평균 19.07, 1 8.17% 감소함을 보였다. 결론적으로 디지털 흉부 단층합성법 검사에서 부가필터로 Ni을 사용할 경우 유효선량 및 DAP 선량 감소, 화질에서 가장 적절함을 알 수 있었다.

지수가중 이동평균 기반의 PPG 신호 동잡음 제거 (The Motion Artifact Reduction from the PPG based on EWMA)

  • 이준연
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.183-190
    • /
    • 2013
  • PPG 신호는 심장의 박동에 동기된 유사 주기 신호이다. 본 논문에서는 PPG 신호의 유사주기성을 이용한 지수가중 이동평균필터 방법을 제안한다. 이 필터링 방법은 PPG 신호를 주기적으로 분리하여 각 주기 신호의 같은 순번에 있는 샘플들끼리 평균을 취하는 방법이다. 연속된 PPG 신호의 주기중에 동잡음이 혼입되었다면 주기를 기준으로 PPG 신호를 분리한 후, 각 주기의 샘플수를 조정하여 같은 샘플수를 가지게 만든다. 이 주기들을 2차원으로 배열한 후 현재 주기부터 이전 각 주기의 샘플끼리 평균을 취함으로써 훼손없이 동잡음을 제거할 수 있었다.

대기중의 중금속 분석을 위한 여지의 전처리 방법에 관한 연구 (The Study on Pre-treatment Method of Filter for Analysing the Heavy Metals in Air Quality)

  • 김광래;이상칠;어수미;김민영;신재영;이재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.16-19
    • /
    • 2002
  • This study was carried out to establish the standardized analysis method in order to decide accurate concentrations of hazardous metals in the air. Acid decomposition method used usually was compared to microwave digestion method. Comparing results of tested background concentration in blank filter, we found that the magnitude of element concentration was Na, Ca, K, Mg, Al and Ba by order. The element concentrations of Glass fiber filter were higher than those of Quartz fiber filter, and the number of undetected components in Glass fiber filter was lower than that in Quartz fiber filter. Thus it is supposed that the concentration of background elements in Glass fiber filter was higher than those in Quartz fiber filter The extraction rate of microwave digestion method was superior to those of acid decomposition method during the test of blank filter as well as SRM of NIST. In case of the SRM of NIST, the average extraction efficiency of acid decomposition Method and microwave pretreatment is 53.8∼82.7%, 81.3∼97.1%, respectively. This result might be caused by the closed system of Microwave, which make outflow and loss of components less. Also microwave digestion method has other merits such as the minimization of time, reagents, and contamination. Furthermore, if the extraction condition, extraction time and used acids are optimized, the better results will be represented.

  • PDF

FMCW 방식의 전파 고도계에서 수신 신호 요동에 대한 영향을 감소하기 위한 다중 필터의 설계 (Design of Multiple Filter for Reducing Received Signal Fluctuation in FMCW Radar Altimeter)

  • 김세윤;이호준;현영오
    • 한국전자파학회논문지
    • /
    • 제21권10호
    • /
    • pp.1085-1093
    • /
    • 2010
  • 본 논문은 FMCW 방식 전파 고도계에서 발생되는 수신신호 요동을 감소시키고, 스텝으로 변화되는 고도의 모서리 검출 특성을 향상시키기 위한 다중필터를 제안하였다. 제안된 필터는 Alpha-trimmed 평균필터와 주파수 변화 제한기, 그리고 1/3 order static필터로 구성되었다. 수신 신호 분석을 이용한 시뮬레이션은 제안된 필터가 이동 평균 필터 및 메디안 필터와 비교하여 오차 감소 성능이 우수함을 확인하였다. 특히, 지면 정지 비행에서 신호의 요동을 제거시키는 능력이 크게 향상되었다.

대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조 (Development of mass aerosol particle generator and fabrication of commercial anti-viral air filter)

  • 박대훈;조윤행;황정호
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.151-159
    • /
    • 2016
  • Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.

잡음제거 필터를 이용한 BGA 패키지 측정에 관한 연구 (A Study on the BGA Package Measurement using Noise Reduction Filters)

  • 진고환
    • 한국융합학회논문지
    • /
    • 제8권11호
    • /
    • pp.15-20
    • /
    • 2017
  • 최근 IT 산업의 발전으로 다양한 분야에서 컴퓨터 융합 기술에 대한 관심이 높아지고 있다. 특히 반도체 분야에서 생산 공정에 반도체 소자의 결함을 검사하기 위하여 카메라와 컴퓨터를 융합한 비전 시스템을 많이 사용하고 있다. 이러한 영상 관련 시스템들은 데이터를 처리하는 과정에서 열화 현상이 발생하기에 주유한 요인인 잡음을 제거하기 위한 다양한 연구가 이루어지고 있다. 이에 본 논문에서는 BGA 패키지 소자를 대상으로 양산 과정에서 결함을 사전에 인식하여 불량을 검출하기 위하여 영상 데이터의 잡음제거에 많이 사용하고 있는 가우시안 필터, 미디언 필터, 평균 필터를 이용한 측정 시스템을 제안한다. 제안 시스템을 BGA 패키지 생산 공정에 적용하면 신속하게 양품과 불량을 판정할 수 있어 생산성이 향상될 것으로 기대된다.

KZ 필터를 이용한 부산지역 PM10의 장기 추세 분석 (Analysis of the Long-term Trend of PM10 Using KZ Filter in Busan, Korea)

  • 도우곤;정우식
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.221-230
    • /
    • 2017
  • To determine the effect of air pollution reduction policies, the long-term trend of air pollutants should be analyzed. Kolmogorov-Zurbenko (KZ) filter is a low-pass filter, produced through repeated iterations of a moving average to separate each variable into its temporal components. The moving average for a KZ(m, p) filter is calculated by a filter with window length m and p iterations. The output of the first pass subsequently becomes the input for the next pass. Adjusting the window length and the number of iterations makes it possible to control the filtering of different scales of motion. To break down the daily mean $PM_{10}$ into individual time components, we assume that the original time series comprises of a long-term trend, seasonal variation, and a short-term component. The short-term component is attributable to weather and short-term fluctuations in precursor emissions, while the seasonal component is a result of changes in the solar angle. The long-term trend results from changes in overall emissions, pollutant transport, climate, policy and/or economics. The long-term trend of the daily mean $PM_{10}$ decreased sharply from $59.6ug/m^3$ in 2002 to $44.6ug/m^3$ in 2015. This suggests that there was a long-term downward trend since 2005. The difference between the unadjusted and meteorologically adjusted long-term $PM_{10}$ is small. Therefore, we can conclude that $PM_{10}$ is unaffected by the meteorological variables (total insolation, daily mean temperature, daily mean relative humidity, daily mean wind speed, and daily mean local atmospheric pressure) in Busan.

독립성분 분석법과 필터뱅크를 기반한 PPG 신호의 동잡음제거 필터 설계 (Design of Filter to Remove Motionartifacts of Photoplethysmography Based on Indepenent Components Analysis and Filter Banks)

  • 이주원;이병로
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1431-1437
    • /
    • 2016
  • 모바일 헬스 장치에서 PPG 신호를 이용하여 심박수를 측정함에 있어 사용자의 움직임인 동잡음에 따라 그 성능이 현저하게 떨어진다. 이의 원인은 PPG 신호의 주파수 대역과 동잡음의 주파수 대역이 겹쳐있기 때문이고, 일반적인 대역필터로는 동잡음을 제거하기가 어렵다. 이러한 문제점 해결하기 위해 본 연구에서는 필터뱅크와 ICA를 이용하여 PPG 신호에 포함되어 있는 동잡음 제거 방법을 제안한다. 제안된 방법을 검증하기 위해 인위적으로 다양한 동잡음을 가하여 기존의 이동평균필터법과 ICA법의 심박수 변화를 비교 평가를 하였다. 이 실험의 결과에서 제안된 기법은 동잡음 환경에서도 기존의 이동평균필터와 ICA 보다 심박수 오차가 매우 낮게 나타났다. 이와 같이 제안된 방법을 헬스케어 단말기 설계에 적용한다면, 보다 안정적인 심박수 측정이 가능할 것으로 사료된다.

바이오필터와 황-석회석을 이용한 마을하수 처리 공정 개발 (Development of Process for Village Scale Wastewater Treatment Using Biofilter and Sulfur-limestone)

  • 김태규
    • 한국농공학회논문집
    • /
    • 제49권2호
    • /
    • pp.75-86
    • /
    • 2007
  • This process which has a connection of biofilter and sulfur-limestone has been developed to treat organic substances including BOD, COD and SS etc. and to treat sulfur-limestone is for denitrification.. The whole process consists of chemical reaction tank, sedimentation tank, trickling filter, denitrification tank The trickling filter is equipped with a reactor filled with absorptive filter, and the sulfur denitrification tank is filled with sulfur-limestone mixed media. After setting up practical facilities whose capacity is 60 tons a day, we have observed the removal efficiencies of pollutants through 60 experiments during Summer and Winter seasons. The average concentration of polluted water was BOD for 3.6 mg/L, $COD_{Mn}$ for 11.3 mg/L, SS for 2.8 mg/L, T-N for 8.6 mg/L, and T-P for 0.8 mg/L, and the rate of treatment efficiencies 96.5%, 84.7%, 96.5%, 79.2%, and 80.8%, respectively was found through the experiments. The average treatment efficiency for BOD and $COD_{Mn}$ was 85.0% and 55.7%, respectively and the average removal efficiency for NH4+-N was 84.9% in the trickling filter. The removal efficiency in the denitrification tank is as follows; The removal rate of $NO_3^--N$ was as high as 93.2% within the compass of pH 6.3 to 7.3 through $16.8{\sim}37.0mg/L$ flown into $NO_3^--N$ and $0.1{\sim}8.3mg/L$ outflown. It had observed that this process has implemented highly efficient and advanced treatment without external carbon sources and internal recycle during its process. In conclusion, this process is suitable for a sewerage in a small village due to the merits of low power consumption and easy maintenance.