• Title/Summary/Keyword: Average Acquisition Ratio

Search Result 29, Processing Time 0.027 seconds

Study on the Trend Analysis according to Grade of G-SEED for University Facilities (대학시설의 녹색건축인증 등급별 득점경향에 대한 조사연구)

  • Ryu, Soo-Hoon;Kim, Hong-Min
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.6
    • /
    • pp.3-10
    • /
    • 2018
  • This study analyzes the average acquisition ratio between the 1st and 4th grade and the distribution and characteristics of the acquisition between the assessment items based on the case of Green Building Certification System(GBCS) for the educational facilities on the university campus. By evaluating the difference between the best scored grade (Green 1st Grade) and the general grade (Green 4th Grade), we classified the cases where the difference between grades with little or big difference. By doing this, we were able to analyze the trend that were difficult to distinguish between difficult to score and an easy task. G-SEED should be used not only as a formal system for certifying certification, but also to provide environmentally-friendly technology for buildings as well as meeting market needs. To do this, it is necessary to further refine the evaluation criteria. In addition, it is necessary to establish a qualitative evaluation system by providing detailed criteria for items that are not distinguishable among grades. It is expected that this study will be used to improve the detailed evaluation items by analyzing trends in the average acquisition rate presented in this study.

Software-based Simple Lock-in Amplifier and Built-in Sound Card for Compact and Cost-effective Terahertz Time-domain Spectroscopy System

  • Yu-Jin Nam;Jisoo Kyoung
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.683-691
    • /
    • 2023
  • A typical terahertz time-domain spectroscopy system requires large, expensive, and heavy hardware such as a lock-in amplifier and a function generator. In this study, we replaced the lock-in amplifier and the function generator with a single sound card built into a typical desktop computer to significantly reduce the system size, weight, and cost. The sound card serves two purposes: 1 kHz chopping signal generation and raw data acquisition. A unique software lock-in (Python coding program to eliminate noise from raw data) method was developed and successfully extracted THz time-domain signals with a signal-to-noise ratio of ~40,000 (the intensity ratio between the peak and average noise levels). The built-in sound card with the software lock-in method exhibited sufficiently good performance compared with the hardware-based method.

Evaluation about Distribution of 18F-DOPA at Striatum by Using Dynamic Study (Dynamic study를 이용한 선조체에서의 18F-DOPA의 분포에 대한 평가)

  • Kim, Jae Il;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.67-71
    • /
    • 2015
  • Purpose At recently, we enter into the aging society and a age-related disease is increasing. Among that, prevalence of degenerative brain disease like Parkin's disease will be increased. So, many radiopharmaceuticals is developed to diagnosis early and to evaluate the performance of therapeutic drugs. Especially $^{18}F-DOPA$ which involved at dopamine synthesis and function of storage is widely used to the diagnosis of Parkinson's disease as well as brain tumors. in the study, we will evaluate the distribution pattern of $^{18}F-DOPA$ at the striatum by using dynamic study. Materials and Methods We used Biograph Truepoint(Siemens, Germany) as PET/CT scanner, injected a $^{18}F-DOPA$ ($600{\pm}30MBq$) to patient (4men, 6women. $67{\pm}11age$) who visited our hospital from June to September, started 95min dynamic study at same time. after finishing acquisition, we reconstructed PET data with 19 frame every 5 minutes, analysed a average counts at ROI's where set at both striatums, anterior putamen, posterior putamen Results Counts in the cerebellum as the background formed a plateau after 90 minutes from the highest out rapidly reduced to 15 minutes. Counts of anterior putamen and posterior gradually increased but formed a plateau after 60min. A count ratio of Striatum to cerebellum was continuously increased up to more than 95 minutes, A count ratios of an anterior putamen to posterior one formed a plateau after 85 minutes. Conclusion The dynamic acquisition can be possible to evaluate a distribution of the $^{18}F-DOPA$ in the striatum and the VOI analysis through a dynamic acquisition and a variety of patterns. Futhermore, to make a uniformed distribution and count ratio of striatum to cerebellum, a static acquisition will have to start 90minutes later after injection.

  • PDF

Packet Acquisition for DS/CDMA-based LEO Satellite communication System (DS/CDMA 저궤도 위성 통신 시스템의 패킷 초기 동기 연구)

  • 김동희;김영초;이상운;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5B
    • /
    • pp.871-878
    • /
    • 2000
  • A divided matched filter-reference filter(MF-RF) technique for LEO satellite packet transmission is proposed to increase the packet throughput in the presence of severe Doppler shift and fading. To overcome the severe Doppler shift, the divided matched filter is adopted where the integration region of matched filter is divided and ouputs of divided matched filer are added to decide the correct pseudo-noise (PN) phase. To maintain the constant false alarm rate in time varying interference and fading channel, the adaptive threshold for acquisition is obtained from the reference filter. As a performance measure, average acquisition time and packet throughput are used, and the effets of the parameters, i.e., Doppler shift, chip energy to noise ratio, user velocity, standard deviation of shadowing, and preamble length are shown.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

An Improved Algorithm for Respiration Signal Extraction from Electrocardiogram Using Instantaneous Frequency Estimation based on Hilbert Transform (힐버트 변환에 기반한 순간주파수 추정을 이용한 개선된 심전도 유도 호흡신호 추출 알고리즘)

  • Park Sung-Bin;Yi Kye-Hyoung;Kim Kyung-Hwan;Yoon Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.10
    • /
    • pp.733-740
    • /
    • 2004
  • In this paper, an improved algorithm for the extraction of respiration signal from the electrocardiogram (ECG) is proposed. The whole system consists of two-lead electrocardiogram acquisition (lead Ⅰ and Ⅱ), baseline fluctuation elimination, R-wave detection, adjustment of sudden change in R-wave area using moving average, and optimal lead selection. In order to solve the problem of previous algorithms for the ECG-derived respiration (EDR) signal acquisition, we proposed a method for the optimal lead selection. An optimal EDR signal among the three EDR signals derived from each lead (and arctangent of their ratio) is selected by estimating the instantaneous frequency using the Hilbert transform, and then choosing the signal with minimum variation of the instantaneous frequency. The proposed algorithm was tested on 15 subjects, and we could obtain satisfactory respiration signals that shows high correlation (r>0.9) with the signal acquired from the chest-belt respiration sensor.

A Comparative Analysis of Risk-to-Performance of Sale and Lease Back: Based on the cases of ship investment company investment and ship acquisition (매도후임대의 리스크 대비 성과의 비교분석: 선박투자회사 출자 및 선박 인수 사례를 중심으로)

  • Chang, Wook
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.1
    • /
    • pp.135-149
    • /
    • 2021
  • Purpose - I analyzes risk-to-performance evaluated in the market using data from sale and lease back. Specifically, I analyze from the perspective of financial institutions that purchase sale and lease back based on the cases of investment by ship investment companies and acquisition of ships. Design/methodology/approach - I use 49 sale and lease back data from 2017 to 2019 for empirical analysis. Findings - The main results of this paper are as follows. First, after sale and lease back of domestic ships, the average amount of sales by the leased shipping company is 25.1 billion won, the average amount of investment by the purchased financial institution is 14.6 billion won (60%) and the average length of the ship is nine years. In ship finance, sale and lease back is deemed to be appropriately used as a means of restructuring for a large amount of money. Second, the main risk factor for sale and lease back of domestic ships is credit risk and can be measured in VaR in practice. As a result of the empirical analysis, the average credit risk burden ratio is 9%. As a major risk factor, low creditworthiness of restructuring companies is the key. Third, as a result of measuring the profitability of financial institutions that purchase sale and lease back of domestic ships at a net current price, it has an average value of 300 million won, but the deviation by case is very large. Fourth, the risk adjusted performance of sale and lease back of domestic ships is 0.54 on average compared to the total risk capital, and 0.52 compared to the stock-risk capital, and as with profitability earlier, the deviation of each case is very large and misaligned. In order to boost the sale and lease back market for large and long-term assets, in order to overcome low profitability as a prerequisite for future participation of commercial purchased financial institutions, it is expected that purchase decisions based on expectations versus risk will be necessary. Research implications or Originality - The results of this paper are expected to broaden the understanding of sale and lease back and foster the ability to assess long-term risk and performance. Based on this, it is believed that rapid restructuring of companies through sale and lease back of large amounts of long-term assets will greatly increase the utility of the domestic financial market.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

The Evaluation of Degradation Characteristics of Silicone Rubber for Outdoor by Leakage Current Monitoring (누설전류 모니터링에 의한 옥외용 실리콘 고무의 열화 특성 평가)

  • Kim, Jeong-Ho;Song, Woo-Chang;Cho, Han-Goo;Park, Yong-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.2
    • /
    • pp.60-64
    • /
    • 2001
  • The degradation process of silicone rubber was investigated by leakage current monitoring in Inclined-Plane method. DAS (Data Acquisition System) with 12-bit, 8-channel A/D converter was prepared. Average current, cumulative charge, current waveform and the number of peak pulses were measured on-line. And, FFT (Fast Fourier Transform) analysis was performed with stored current waveform. Besides, maximum erosion depth was measured in order to use as the indicator of the degradation process. So, the results of leakage current components and maximum erosion depth measurements were compared to find one or more components which have trends of changing similarly to that of erosion process. The result suggests that the ratio of peak current to r.m.s. current, harmonic contents and the number of peak pulses are well corresponding with the degradation process.

  • PDF

Performance of Interference Mitigation with Different Wavelets in Global Positioning Systems

  • Seo, Bo-Seok;Park, Kwi-Woo;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.8 no.4
    • /
    • pp.165-173
    • /
    • 2019
  • In this paper, we apply a discrete wavelet packet transform (DWPT) to reduce the influence of interference in global positioning system (GPS) signals and compare the interference mitigation performance of various wavelets. By applying DWPT to the received signal, we can gradually divide the received signal band into low-pass and high-pass bands. After calculating the average power for the separate bands, we can determine whether there is interference by comparing the value with the given threshold. For a band that includes interference, we can reconstruct the whole band signal using inverse DWPT (IDWPT) after applying a nulling method that sets all of the wavelet coefficients to 0. The reconstructed signals are correlated with the pseudorandom noise (PRN) codes to acquire GPS signals. The performance evaluation is based on the number of satellite signals whose peak ratio (defined as the ratio of the first and second correlation peak values in the acquisition stage) exceeds the threshold. In this paper, we compare and evaluate the performance of 6 wavelets including Haar, Daubechies, Symlets, Coiflets, Biorthogonal Splines, and Discrete Meyer.