• 제목/요약/키워드: Auxiliary heat

검색결과 130건 처리시간 0.024초

보조용기의 열전달특성이 공기스프링의 성능에 미치는 영향 (Effectiveness of a Heat Transfer Characteristics of an Auxiliary Chamber for Performance of an Air Spring)

  • 장지성
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.121-127
    • /
    • 2013
  • The air spring is used widely because of the easy change of spring constant, and, a superior vibration and shock insulation performance. Among the apparatus using the merits of that, the air spring connected an auxiliary chamber has been developed and used as a component of suspension system for an automobile and a railroad car. The purpose of this study is to suggest a design method reflecting heat transfer effect for an air spring system connected auxiliary chamber. In order to do so, this study investigates change of reaction force along with variations in heat transfer coefficient, and, analyzes an effectiveness of a heat transfer characteristics of an auxiliary chamber for external force attenuation characteristics and impedance characteristics of an air spring connected an auxiliary chamber.

고효율엔진 차량 히트펌프 시스템 개발 (Development of Heat Pump System for High Efficiency Engine Vehicle)

  • 박병덕;원종필;이원석
    • 한국산업융합학회 논문집
    • /
    • 제10권1호
    • /
    • pp.21-26
    • /
    • 2007
  • As DDI or GDI engine discharges very low heat due to its high thermal efficiency, the heat source is not enough for heating the passenger compartment in cold climate condition. To remedy the heating problem, the conventional HFC-134a automotive air-conditioning system has been attempted to run as a heat pump mode. Futhermore, an auxiliary electric heater of new type was equipped to the heat pump air-conditioning loop as a new approach. Hence, a proto-type heat pump air conditioner has been made and tested to investigate the feasibility of the HFC-134a automobile air-conditioning system that could be worked as a heat pump. The experiment results showed that the sufficient heating capacity could be obtained by adding a heat pump with an new electric type auxiliary heater into the conventional heat core in low temperature condition.

  • PDF

냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구 (A study on the solar assisted heating system with refrigerant as working fluid)

  • 김지영;고광수;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

각종 보조설비와 연계된 열병합발전시스템에서 퍼지이론을 적용한 단기운전계획수립 (Shot -term Operation Scheduling Using Fuzzy Theory on Cogeneration Systems Connected with Auxiliary Equipments)

  • 이종범;정창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.553-555
    • /
    • 1995
  • This paper presents the optimal short-term operation scheduling by using on cogeneration systems connected with auxiliary equipments. Simulation is performed in case of the bottomming cycle which generates the demand heat preferentially. Heat storage tank, electricity charger, auxiliary boiler and independent generator are considered as auxiliary equipments connected to cogeneration systems. The results of simulation show the auxiliary equipments can be effeciently operated in case of the bottomming cycle by modeling proposed in this paper. The effectiveness of operation scheduling gained by application of fuzzy theory is evaluated by detailed comparison and investigation of the simulation results.

  • PDF

지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구 (A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source)

  • 박시훈;김종현;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

Comparison of auxiliary Feedwater and EDRS Operation during Natural Circulation of MRX

  • Kim, Jae-Hak;Park, Goon-Cherl
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.514-519
    • /
    • 1997
  • The MRX is an integral type ship reactor with 100 MWt power, which is designed by Japan Atomic Energy Research Institute. It is characterized by integral type PWR, in-vessel type control roe drive mechanism, water-filled containment vessel and passive decay heat removal system. Marine reactor should have high passive safety. Therefore, in this study, we simulated the loss of flow accident to verify the passive decay heat removal by natural circulation using RETRAN-03 code. auxiliary feed water systems are used for decay heat removal mechanism and results are compared with the loss of flow accident analysis using emergency decay heat removal system by JAERI. Results are very similar to case of EDRS 1 loop operation in JAERI analysis and decay heat is successfully removed by natural circulation.

  • PDF

주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구 (A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station)

  • 김기성;이상원;송동우
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.7-13
    • /
    • 2021
  • 최근 주유취급소 내의 건축물에 편의점, 자동차 수리점 등의 부대시설이 증가하고 있다. 이에 따라 부대시설에서 화재 발생 시 고정주유기에 미치는 화재의 영향을 알아보고 현행 규정의 타당성을 검증할 필요성이 있다. 본 논문에서는 부대시설에서의 화재 시 고정주유기까지의 이격거리에 따라 미치는 복사열의 영향을 알아보는 연구를 진행하였다. FDS 5.5.3을 사용하여 화재모델링을 하였고, 화원의 크기는 실규모 화재평가 장치를 이용한 사무실의 연소실험을 통한 단위면적당 열방출율을 입력하였다. 화원과 고정주유기의 이격 거리는 '위험물안전관리법 시행규칙 별표13 주유취급소의 위치·구조 및 설비의 기준'에서 명시하는 2 m 부터 이격거리를 1 m 간격으로 늘여가며 10 m까지 화원의 크기를 Case A의 경우 512.41 kW/m2, Case B의 경우 250 kW/m2로 설정하여 총 13개의 시나리오를 구성하여 연구를 진행하였다. 시뮬레이션을 통해 2 m의 이격거리는 부대시설의 화재 시에 주유기의 안전성을 확보하지 못하는 것으로 나타났으며 최소 4m 이상의 이격거리에서 복사열이 피해를 미치지 않는 것으로 나타났다. 이에 따라 부대시설의 화재 발생시 복사열을 차단할 수 있는 설비가 필요하며 부대시설의 용도를 제한하거나 건축물과 고정주유기의 이격거리를 다시 제고하는 방안이 필요할 것이다.

에너지 수요처의 사용특성에 따른 태양열 급탕시스템의 효율분석 (Analysis of Efficiency of Solar Hot Water System based on Energy Demand)

  • 전용준;박경순
    • 한국태양에너지학회 논문집
    • /
    • 제37권5호
    • /
    • pp.39-47
    • /
    • 2017
  • In a hot water system using solar energy, solar heat is not simply collected by the heat collecting plate, but by heat exchange between the solar collector (flat or vacuum type) and the hot water storage tank. Therefore, the amount of collected solar energy depends on the hot water usage patterns that determine the temperature of the thermal storage tank. Also, if the temperature of the hot water stored in the storage tank exceeds the dangerous temperature during the summer, the heat must be released for safety. If the temperature of the hot water in the storage tank is low, it is necessary to heat by the auxiliary heat source. In this study, three buildings are defined as hotel, swimming pool, and school facilities. And we calculated the released heat energy, auxiliary heat source, and pure storage heat energy based on different hot water usage patterns and installation angle of the solar collectors.

전기 철도차량용 보조전원장치의 컨버터에 관한 연구 (A study on the converter of auxiliary power supply for electric railway vehicles)

  • 김재문;김양수;이종성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.467-468
    • /
    • 2007
  • This paper describes characteristics of converters of auxiliary power supply for electric railway vehicles. Auxiliary power supply is called Static Inverter(SIV) which supplied lamps, air conditioning and heat equipments, control systems, etc. Simulation results shows that line No.1 cheon contains low harmonics compared with those of KTX.

  • PDF

위성 운송용 컨테이너의 단열 설계와 열 유동 해석에 관한 연구 (Study on Thermal Insulation Design and Heat Flow Analysis of Spacecraft Shipping Container)

  • 박상래;이춘우;김진택
    • 항공우주시스템공학회지
    • /
    • 제14권1호
    • /
    • pp.8-15
    • /
    • 2020
  • 본 논문은 위성을 발사장까지 안전하게 운반하기 위해, 열이나 외부 온도가 심하게 변화하는 조건에서 위성 컨테이너 내부 온도를 일정하게 유지할 수 있도록 컨테이너 벽면 및 경계층 단열 설계 방법을 제시하고 위성 운반용 컨테이너 외부 환경에 대한 열 유동 해석 및 위성 내부 열 전달 해석을 통해 위성 컨테이너 내부 온도가 일정하게 유지되는지 분석하였다. 컨테이너 내부 유동 해석을 통해 컨테이너 내 위성 주변의 유동이 원활 한지 유동 분포를 확인하였으며, 보조 팬 및 공조시스템과 특별한 그릴 가이드 구조 설계 안을 제시하고자 한다.