• 제목/요약/키워드: Auxiliary Surface

검색결과 108건 처리시간 0.026초

보조 전극을 이용한 패턴된 전극에서의 전류 밀도 분포의 최적화 (Optimization of Current Distributions of Electroplating on Patterned Substrates with the Auxiliary Electrode)

  • 김남석;모화동;강탁
    • 한국표면공학회지
    • /
    • 제28권3호
    • /
    • pp.164-173
    • /
    • 1995
  • Based on the potential-theory model for secondary current distribution, we could predict the thickness distributions of electroplating on patterned substrates with the different size of the auxiliary electrode. The substrates contain lithographic patterns at each sample geometry. Each sample geometry had different current distribution at the same condition except the size of the auxiliary electrodes. The size effect of the auxiliary electrode on thickness distribution of electrodeposition on patterned electrode was investigated in a series of experiments. Copper was galvanostatically deposited from an acid-sulfate solution in a reciprocating paddle cell. The thickness distributions of the workpiece scale measured by profilometry across the specimen were in good agreement with the current distribution predicted by boundary element method.

  • PDF

보조접지그리드의 시설에 의한 대지표면전위경도의 저감 (Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids)

  • 이승칠;엄주홍;이복희;김효진
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.121-129
    • /
    • 2002
  • 본 논문에서는 효과적인 접지그리드 설치기법에 대하여 기술하였으며, 낙뢰나 지락고장서지, 개폐서지 등으로 부터 인체의 감전보호나 컴퓨터를 비롯한 전기·전자기기의 보호를 위한 접지그리드의 시설 및 배치방법에 따른 실험적인 평가를 수행하였다. 접지그리드의 배치에 따른 대지표면전위경도의 분석과 위험전압으로 작용하는 대지 표면전위상승의 억제에 주안점을 두고 실험용 모델접지전극을 시설한 후 임 펄스전류를 인가하였다. 기존의 등간격 접지그리드의 결점을 보완하기 위해 접지그리드에 경사를 가지는 보조접지그리드를 시설하였으며, 보조접지그리드를 시설한 접지시스템에서는 인체나 전기·전자기기에 위험전압으로 작용하는 대지표면전위경도를 최대 50%이상 완화시키는 효과를 얻었다.

기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가 (Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter)

  • 이채린;이현화;임재한;송승영
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

Gigaspora 속(屬)과 Scutellospora 속(屬) 아버스큘 균근균(菌根菌)의 균사생장(菌絲生長), 보조세포 발달(發達), 손상된 균사재생(菌絲再生)의 과정(過程) (Hyphal growth, auxiliary cell development and hyphal healing process of arbuscular mycorrhizal fungi, Gigaspora and Scutellospora genera)

  • 가강현;구창덕;이창근
    • 한국균학회지
    • /
    • 제22권1호
    • /
    • pp.36-45
    • /
    • 1994
  • 아버스큘 균근균인, Gigaspora margarita Scutellospora heterogama, S. verrucosa의 포자를 발아시켜서 균사의 생장, 보조세포 발달 그리고 절단된 균사의 회복과정을 조사하였다. 발아된 균사는 배지의 표면과 내부 및 바닥에서 생장하였으며, 배지표면에서는 19-23일째, 배지바닥에서는 40-51일째에 생장을 멈추었다. 보조세포는 포자 발아 후 7-9일째에 2차 균사에서 새로 나온 균사 위에 형성되기 시작하였으며 배지의 표면이나 바닥, 그리고 배지속에서도 발달하였다. G. margarita와 S. heterogama의 원형질 유동속도는 각각 $2.7-3.3\;{\mu}m/s$$3.8-4.3\;{\mu}m/s$이었다. 균사가 절단되면 포자쪽 균사의 끝 부분에서 새로운 균사가 뻗어나와 끊어진 부분을 다시 연결하여 계속 생장하였다. 이러한 절단된 균사의 회복 과정은 균근균이 기주식물과 오랜 공생관계를 맺으면서 영양적으로는 절대적으로 식물에 의존함을 나타내는 것이라고 생각한다.

  • PDF

미세 물체 조작을 위한 3젓가락형 집게의 설계 및 제작 (Design and Fabrication of a 3 Chopstick Gripper for Microparts)

  • 박종규;문원규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.1067-1071
    • /
    • 1997
  • A new type of gripper for micrometer-size objects is developed using piezoelectric multi-layer benders. It is composed of three chopsticks, two of which are designed to grip micro-objects. The third one is reserved for helping the two when objects are released from the chopsticks. It is well known that a micro object is much easier to grasp than to release it after holding it. The electrostatic force between the chopsticks and an object is believed to be the main cause of adhesion in a dry environment. The surface tension becomes very important when liquids are present or in a liquid. The third auxiliary chopsticks is introduced to solve there surface effects. All the three chopsticks are made of tungsten wires with sharpened ends by etching. When grasping microparts, the two chopsticks are utilized, and, when releasing them anywhere the parts are located, the third one reduces the electrostatic force between the objects and the chopstick may be to help the other two chopsticks to hold an objects in a desired orientation. We constructed the three chopstick gripoer for micro objects and test their function by holding and releasing an object of a diameter of 100 micrometers. We make use of open loop voltage control. The bender displacement resolution is sub-micrometer. The gripping forces, about tens of mN are obtained. The experiment shows that the third auxiliary chopstick functions effectively.

  • PDF

겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가 (Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter)

  • 이현화;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

The Influence of Fuel Spray Characteristics on the Engine Performance and Emission in the Direct Injection Type Diesel Engine

  • Bakar Rosli Abu;Lee Chang-Sik
    • 한국분무공학회지
    • /
    • 제2권2호
    • /
    • pp.43-50
    • /
    • 1997
  • The purpose of this investigation is to carry out, the influence factor on the fuel spray characteristics for improve the engine combustion performance and exhaust omission in direct injection type diesel engine. The fuel properties, fuel spray structure and the shape or the piston surface of diesel engine play an important role of engine combustion process and exhaust emission. In order to obtain the effect of using auxiliary chamber and emulsified fuel on the fuel spray characteristics the experiment un conduct with single cylinder direct injection type diesel engine to examine the engine performance and gas emission. The results of this investigation showed that the increase auxiliary chamber volume and emulsified fuel give an effect on the fuel spray characteristics by reduced the concentration of nitric oxide emission in the combustion chamber. Also it can improve the combustion characteristics such as cylinder pressure, rate of pressure rise and rate of heat release.

  • PDF

Hull Cell에서 전류분포의 균일화에 관한 연구 (A Study on Uniformity of Current Distribution in Hull Cell)

  • 여운관
    • 한국표면공학회지
    • /
    • 제27권6호
    • /
    • pp.340-346
    • /
    • 1994
  • The method of uniforming current distribution in Hull cell are studied by using auxiliary anode, current shield bipolar electrode, and combinings bipolar electrode with current shield in order to find a way of uni-form deposition. The current density distributions are measured by each ammeter of the same inner resistance connected to divided cathode pannel respectively. The current density distributions of cathode electrode divided into five sections with 5mm width have a tendency of linear inclination, and that of twenty sections have a tendency of smoother curve than the curve of original Hull cell pannel. Their results showed lower value on the high current density portion and higher value on the low portion than that original Hull cell pannel. The current distribution in Hull cell is able to unify by using auxiliary anode, or combining bipo-lar electrode with current shield, but not efficient in using one of both individually.

  • PDF

하류하천의 영향 최소화를 위한 보조 여수로 최적 활용방안 검토 (The Optimal Operation on Auxiliary Spillway to Minimize the Flood Damage in Downstream River with Various Outflow Conditions)

  • 유형주;주성식;권범재;이승오
    • 한국방재안전학회논문집
    • /
    • 제14권2호
    • /
    • pp.61-75
    • /
    • 2021
  • 최근 기후변화로 인해 강우강도 및 빈도의 증가에 따른 집중호우의 영향 및 기존 여수로의 노후화에 대비하여 홍수 시 하류 하천의 영향을 최소화할 수 있는 보조 여수로 활용방안 구축이 필요한 실정이다. 이를 위해, 수리모형 실험 및 수치모형 실험을 통하여 보조 여수로 운영에 따른 흐름특성 변화 검토에 관한 연구가 많이 진행되어 왔다. 그러나 대부분의 연구는 여수로에서의 흐름특성 및 기능성에 대한 검토를 수행하였을 뿐 보조 여수로의 활용방안에 따른 하류하천 영향 검토 및 호안 안정성 검토에 관한 연구는 미비한 실정이다. 이에 본 연구에서는 기존 여수로 및 보조 여수로 방류 조건에 따른 하류영향 분석 및 호안 안정성 측면에서 최적 방류 시나리오 검토를 3차원 수치모형인 FLOW-3D를 사용하여 검토하였다. 또한 FLOW-3D 수치모의 수행을 통한 유속, 수위 결과와 소류력 산정 결과를 호안 설계허용 기준과 비교하였다. 수문 완전 개도 조건으로 가정하고 계획홍수량 유입 시 다양한 보조 여수로 활용방안에 대하여 수치모의를 수행한 결과, 보조 여수로 단독 운영 시 기존 여수로 단독운영에 비하여 최대유속 및 최대 수위의 감소효과를 확인하였다. 다만 계획홍수량의 45% 이하 방류 조건에서 대안부의 호안 안정성을 확보하였고 해당 방류량 초과 경우에는 처오름 현상이 발생하여 월류에 대한 위험성 증가를 확인하였다. 따라서 기존 여수로와의 동시 운영 방안 도출이 중요하다고 판단하였다. 여수로의 배분 비율 및 총 허용 방류량에 대하여 검토한 결과 보조 여수로의 방류량이 기존 여수로의 방류량보다 큰 경우 하류하천의 흐름이 중심으로 집중되어 대안부의 유속 저감 및 수위 감소를 확인하였고, 계획 홍수량의 77% 이하의 조건에서 호안의 허용 유속 및 허용 소류력 조건을 만족하였다. 이를 통하여 본 연구에서 제안한 보조 여수로 활용방안으로는 기존 여수로와 동시 운영 시 총 방류량에 대하여 보조 여수로의 배분량이 기존 여수로의 배분량보다 크게 설정하는 것이 하류하천의 영향을 최소화 할 수 있는 것으로 나타났다. 그러나 본 연구는 여수로 방류에 따른 대안부에서의 영향에 대해서만 검토하였고 수문 전면 개도 조건에서 검토하였다는 한계점은 분명히 있다. 이에 향후에는 다양한 수문 개도 조건 및 방류 시나리오를 적용 및 검토한다면 보다 효율적이고, 효과적인 보조 여수로 활용방안을 도출이 가능할 것으로 기대 된다.

TUNNELLING IN SOFT GROUND IN URBAN AREAS

  • Fujita, Keiichi
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1990년도 PROCEEDINGS OF THE FIRST KOREA-JAPAN JOINT GEOTECHNICAL SEMINAR ON EXCAVATION and TUNNELING IN URBAN AREAS
    • /
    • pp.9-24
    • /
    • 1990
  • Most tunnels in soft soils in urban areas are constructed by shield tunnelling method for environmental reasons. Ground surface settlements are caused by shield tunnelling so that auxiliary measures are often required. Simple methods to predict ground surface settlement are given. The use of the slurry or the earth pressure balance shield machine and the application of new methods of grouting with computer aided operation control systems decreases the ground surface settlement to 3 mm. The construction cost of tunnels is almost identical whichever type of shield machine is employed according to a statistical investigation.

  • PDF