• Title/Summary/Keyword: Automatic thickness measurement

Search Result 36, Processing Time 0.022 seconds

A Study on Worst-Case Analysis of 2-Stage Amplifier in Ku-Band SSPA for Communication Satellite (위성채용 Ku-Band SSPA를 위한 2-단 증폭기의 Worst-Cast Analysis에 관한 연구)

  • Ki Hyeok Jeong;Sang Woong Lee;Young Chul Lee;Chull Chai Shin
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.33-40
    • /
    • 1992
  • In this paper, We designed a 2-stage amplifier for transponder of satellite with dual GaAs FETs NE13783, and performed the worst-case analysis for circuit qualification in the space environment. The bandwidth of amplifier was chosen 11.7-12.2 GHz which is the down link frequency band for domestic Ku-band satellite communication, and the alumina substrate with 25 mil of thickness. The design and optimization of amplifier was achieved by the commercial CAD program TOUCHSTONE and the measurement was performed through the automatic network analyzer.

  • PDF

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

A Red Ginseng Internal Measurement System Using Back-Projection (Back-Projection을 활용한 홍삼 내부 측정 시스템)

  • Park, Jaeyoung;Lee, Sangjoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.10
    • /
    • pp.377-382
    • /
    • 2018
  • This study deals with internal state and tissue density analysis methods for red ginseng grade determination. For internal measurement of red ginseng, there have been various studies on nondestructive testing methods since the 1990s, It was difficult to grasp the most important inner hole and inside whites in the grading. So in this study, we developed a closed capturing device for infra-red illumination environment, and developed an internal measurement system that can detect the presence and diameter of inner hole and inside whites. Made devices consisted of infrared lights with a high transmission rate of red ginseng in 920 nanometer wave band, a infra-red camera and a Y axis actuator with a red ginseng automatically controlled focus on the camera. The proposed algorithm performs an auto-focus system on the Y-axis actuator to automatically adjust the sharp focus of the object according to the size and thickness. Then red ginseng is rotated $360^{\circ}$ at $1^{\circ}$ intervals and 360 total images are acquired, and reconstructed as a sinogram through Radon transform and Back-projection algorithm was performed to acquire internal images of red ginseng. As a result of the algorithm, it was possible to acquire internal cross-sectional image regardless of the thickness and shape of red ginseng. In the future, if more than 10,000 different shapes and sizes of red ginseng internal cross-sectional image are acquired and the classification criterion is applied, it can be used as a reliable automated ginseng grade automatic measurement method.

Development of On-line Grading Algorithm of Green Pepper Using Machine Vision (기계시각에 의한 풋고추 온라인 등급판정 알고리즘 개발)

  • Cho, N. H.;Lee, S. H.;Hwang, H.;Lee, Y. H.;Choi, S. M.;Park, J. R.;Cho, K. H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.571-578
    • /
    • 2001
  • Production of green pepper has increased for ten years in Korea, as customer's preference of a pepper tuned to fiesta one. This study was conducted to develop an on-line fading algorithm of green pepper using machine vision and aimed to develop the automatic on-line grading and sorting system. The machine vision system was composed of a professive scan R7B CCD camera, a frame grabber and sets of 3-wave fluorescent lamps. The length and curvature, which were main quality factors of a green pepper were measured while removing the stem region. The first derivative of the thickness profile was used to remove the stem area of the segmented image of the pepper. A new boundary was generated after the stem was removed and a baseline of a pepper which was used for the curvature determination was also generated. The developed algorithm showed that the accuracy of the size measurement was 86.6% and the accuracy of the bent was 91.9%. Processing time spent far grading was around 0.17 sec per pepper.

  • PDF

The TDDB Characteristics of Thin $SiO_2$ with Stress Voltage Polarity (스트레스전압 극성에 따른 얇은 산화막의 TDDB 특성)

  • Kim, Cheon-Soo;Yi, Kyoung-Soo;Nam, Kee-Soo;Lee, Jin-Hyo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.5
    • /
    • pp.52-59
    • /
    • 1989
  • The reliability of the thin thermal oxide was investigated by using constant current stress method. Polysilicon gate MOS capacitors with oxide thickness range of 20-25nm were used in this experiment. Automatic measurement and statistical data analysis which were essential in reliability evaluation of VLSI process preformed by HP 9000 computer. Based on TDDB results, defect density, breakdown charge (Qbd) and lifetime of oxide film were evaluated. According to the polarity of the stress, some different characteristics were shown. Defect density was 62/$cm^2$ at negative gate injection. The value of Qbd was about 30C/$cm^2$ at positive gate injection, and about 21C/$cm^2$ at negative. The current density acceleration factor was 1.43$cm^2$/A for negative gate injection, and 1.25$cm^2$/A for positive gate injection.

  • PDF

Electrochemical and Optical Studies on the Passivation of Nickel (니켈의 부동화에 관한 전기화학적 및 광학적 연구)

  • Dong Jin Kim;Woon-Kie Paik
    • Journal of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.369-377
    • /
    • 1982
  • The technique of combined-measurement of reflectance and ellipsometric parameters was used for studying the anodic film formed on nickel surface in basic solutions. An ellipsometer was automated for transient measurements by way of modulating the plane-polarized light with the Faraday effect. Surface film was formed electrochemically by applying a potential step from the reduction potential range to the passivation range on a polished, high-purity, polycrystalline nickel specimen. From that instant, the changes in the reflectance(r) and the ellipsometric parameters(${\Delta},{\Psi}$) of the surface film were recorded by the automatic ellipsometer. Three exact simultaneous equations including these optical signals, ${\Delta},{\Psi}$ and r were solved numerically with a computer in order to determine the optical properties, n, k, and the thickness, ${\tau}$, of the surface film. From the computed results which showed dependence on pH and time, it was found that passivation of nickel can be effectively attained by surface film thinner than $15{\AA}$ and this passivation film has a small optical absorption coefficient. It seemed that a high pH environment enhances the rate of passivation and is favorable for a denser structure of the surface film. The experimental evidence is in accordance with the hypothesis that the composition of the passive film can be approximated by $Ni(OH)_2$ in the early stage of passivation and that as time passes the composition changes partially toward that of NiO through dehydration.

  • PDF