• 제목/요약/키워드: Automatic test stand

검색결과 6건 처리시간 0.02초

소형가스터빈용 C-9N 스탠드 설비에 대한 개념설계 (Conceptual Design on the C-9N Test Stand for Small-sized Gas Turbine)

  • 김상화;한풍규;김영수
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.325-328
    • /
    • 2007
  • 본 연구에서는 소형가스터빈의 고공 및 속도시험, 환경시험 등을 수행하기 위해, 러시아의 SCIAM 연구소에 설치된 기존 대형 시험설비를 개량하여, C-9N 시험스탠드를 개발하는 과정에서 수행된 개념적 설계의 내용을 다루고 있다. 본 시험 스탠드는 환경모사 시스템, 항온유지 시스템, 냉각/건조 시스템, 추력측정 시스템, SAR 시스템으로 구성되어 있다.

  • PDF

Stand-Alone Pico-Hydro Generation System using a High-Efficiency IPM Synchronous Generator

  • Kurihara, Kazumi;Kubota, Tomotsugu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.121-125
    • /
    • 2014
  • This paper presents a successful stand-alone pico-hydro generation system using a high-efficiency interior permanent-magnet (IPM) synchronous generator. A 1-kW 4-pole V-type IPM generator with low voltage regulation is used for laboratory test in stand-alone hydro energy conversion system. It has been found from experimental results that the constant output voltage is supplied stably by the proposed system under wide speed range.

기립보조형 전동휠체어 개발에 따른 장애인 사용성 평가 연구 (A Study on the Usability Test of People with Disabilities According to the Development of Powered Wheelchair of Standing Support Type)

  • 이근민;김동옥;황보치욱
    • 재활복지
    • /
    • 제20권1호
    • /
    • pp.211-233
    • /
    • 2016
  • 본 연구는 교통약자에게 안전한 이동 및 기립보조의 전동휠체어를 개발하여 휠체어 장애인 31명을 대상으로 사용성 평가를 통해 문제점과 개선방안을 제시하는데 있다. 본 연구 결과를 보면 다음과 같다. 첫째, 교통약자에게 기립 및 착석이 가능하고, 좁은 공간을 이동할 수 있는 근거리 이동수단으로 사용될 수 있는 기립형 전동휠체어를 개발하였다. 본 연구개발 시제품의 사용성 평가에서 장애인 집단 중 수동휠체어집단대상자 16명과 전동휠체어집단 15명으로 나누어 사용성 평가항목의 60개 유형으로 측정한 결과를 나타내었다. 2개 집단의 전체 평균값이 2.72점, 편차는 0.820점으로 나타났으며, 이를 세부적으로 나누어보면 수동휠체어집단대상자의 평균값은 2.85점, 전동휠체어 집단대상자의 평균값은 2.57점으로 나타났다. 이중 수동휠체어 및 전동휠체어의 탑승동작과 하차동작 시 불편여부에서 승하차 모두 가장 불편하다고 응답하였으며, 이에 운전자의 안전한 승하차를 위해 양하지 지체장애인의 인체공학적인 설계가 필요한 것으로 나타났다. 둘째, 장애인 사용성 평가에서 나타난 불편사항과 개선방안을 토대로 추가적인 연구개발이 이루어져 교통약자들에게 스스로 탑승하여 기립 후 이동하며 간단한 일상생활하는데 있어 삶의 질을 높이는데 기여할 것으로 사료된다.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

적응기법을 이용한 Feed-forward AGC 기술 개발 (Development of Feed-forward AGC using Adaptive Control Algorithm)

  • 홍성철;이영교
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.168-171
    • /
    • 2003
  • Generally RF AGC (Roll Force Automatic Gauge Control) controls the roll gap using the variation of rolling force caused by the roll eccentricity and the entry thickness of material, but RE AGC takes the bad effect of the roll eccentricity. The Feed-forward (FF) AGC method, which controls the next stand roll gap by the estimation of the thickness variation due to skid mark is needed to supplement the shortage of RF AGC. In this paper, an adaptive filtering method which takes account of the kind of material, the final objective thickness and the rolling speed is proposed to predict skid mark thickness variation. In addition, an improved estimation method of control point using a speedometer and looper angle is suggested. Via on line test, the performance improvement of the suggested FF AGC method is verified.

  • PDF

반자동정식기 작업 성능 분석 (Analysis of Working Capacity of a Hand-fed Transplanter)

  • 문성동;민영봉;박중춘
    • 생물환경조절학회지
    • /
    • 제6권3호
    • /
    • pp.159-167
    • /
    • 1997
  • 플러그육묘의 대량생산 보급에 대처하기 위하여는 정식기의 보급이 필요하다. 본 연구에 서는 국내보급중인 반자동정식기의 정식성능을 조사 분석하므로써 기계정식 작업시 최적작업조건 구명과 정식기 연구 개발의 기초 자료를 획득하고자 실시하였고, 정식시험을 실시한 결과를 요약하면 다음과 같다. 1. 호퍼의 크기는 정식자세와 정식율에 영향을 미치고, 진압이 불량한 정식육묘는 1일후 고사하므로 재관수가 필요하였다. 따라서 복토진압장치는 전후좌우 진압법이 좋으며, 2중관수장치에 의하여 정식시의 관수량을 늘려야할 것으로 생각되나 물통의 용량이 또한 커지게 되어 기계의 운전 조작이 어렵게 되므로 자동육묘공급 정식기는 공간문제와 1~2인 작업을 전제로 할 때 효율면에서 자동관수는 없는 것이 바람직할 것으로 사료된다. 2. 반자동정식기는 몇 가지의 구조적 개선이 필요하지만 현재로도 정식기계의 운전을 주행 속도 14m/min 이하, 정식깊이 2~3cm, 간격 30cm로 하고 고추 육묘는 128공의 45일 육묘, 배추는 128공의 25육묘를 사용하면 플러그육묘의 정식에 적합한 것으로 생각된다.

  • PDF