• 제목/요약/키워드: Automatic test equipment

검색결과 189건 처리시간 0.025초

Cost-Efficient and Automatic Large Volume Data Acquisition Method for On-Chip Random Process Variation Measurement

  • Lee, Sooeun;Han, Seungho;Lee, Ikho;Sim, Jae-Yoon;Park, Hong-June;Kim, Byungsub
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권2호
    • /
    • pp.184-193
    • /
    • 2015
  • This paper proposes a cost-efficient and automatic method for large data acquisition from a test chip without expensive equipment to characterize random process variation in an integrated circuit. Our method requires only a test chip, a personal computer, a cheap digital-to-analog converter, a controller and multimeters, and thus large volume measurement can be performed on an office desk at low cost. To demonstrate the proposed method, we designed a test chip with a current model logic driver and an array of 128 current mirrors that mimic the random process variation of the driver's tail current mirror. Using our method, we characterized the random process variation of the driver's voltage due to the random process variation on the driver's tail current mirror from large volume measurement data. The statistical characteristics of the driver's output voltage calculated from the measured data are compared with Monte Carlo simulation. The difference between the measured and the simulated averages and standard deviations are less than 20% showing that we can easily characterize the random process variation at low cost by using our cost-efficient automatic large data acquisition method.

표준관입시험 자동기록장치의 N치 특성 연구 (A Study on the N Values Characteristics of Automatic Recording System of SPT)

  • 윤원섭;박면규;한재운;신승구;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1168-1176
    • /
    • 2010
  • Currently drilling investigation and the SPT in parallel not only organization and peculation sincerity quality historian of test to be old the data was abundant with the site ground investigation test which is representative and the research of empirical formula in compliance with many scholar was accomplished and was come. The data which is like this wide is used with geotechnical engineering data of plan and space-time of the field which is various. SPT with tentative voluntary skillful degree record method of variety and technical expert of equipment, according to site conditional is consistent the quality of ground condition but cannot be made to show there is a tendency and specially the point whose is difficult actually accurately to follow the interval which decides in quality as a matter of tentative standard of drill and the test in parallel and a tentative method exists. From the research which sees consequently also the skill of variety and technical expert of equipment of SPT, strong point of the SPT automation logger will be able to complement the problem point of quality etc. of site condition under comparison analyzing should have been boiled about SPT of existing and tentative methods and N-value.

  • PDF

고속 자동 테스트 장비용 비교기 구현 (Implementation of a High Speed Comparator for High Speed Automatic Test Equipment)

  • 조인수;임신일
    • 한국산업정보학회논문지
    • /
    • 제19권3호
    • /
    • pp.1-7
    • /
    • 2014
  • 본 논문은 자동시험장비 (ATE) 시스템의 측정 회로에 사용하는 비교기 설계에 관한 것이다. 이 비교기 전체 블럭은 연속 형의 고속 비교기, 차동차이증폭기, 그리고 출력 단으로 구성되어 있다. 연속 형의 고속 비교기는 높은 주파수(1~800MHz) 및 넓은 범위(0~5V)의 입력신호를 받아들이기 위해, 고속의 rail-to-rail 증폭기를 첫 단에 두었다. 또한 동작 속도를 높이기 위하여 고속의 전치증폭기와 래치를 순차적으로 구성하였다. 두 시험 소자(DUT) 간 출력 신호 차이를 검출함에 있어, 공통 신호와 차동 신호 차이를 모두 감지하기 위하여 차동차이 증폭기(DDA)를 사용하였다. 이 비교기는 $0.18{\mu}m$ BCDMOS 공정을 사용하여 칩으로 구현되었으며, 5mV의 신호 차이를, 800 MHz의 신호까지 비교가 가능하다. 구현된 칩 면적은 $620{\mu}m{\times}830{\mu}m$이다.

지중열전달특성 평가에 관한 해석 및 실험적 방법에 관한 연구 - 지중 열물성치 및 보어 홀 열 저항 평가 - (Study on Analytical and Empirical Methods for Assessing Geo-Heat Transfer Characteristics)

  • 박준언;백남춘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.427-432
    • /
    • 2005
  • This study treats the advantage of in situ line source method measuring the heat transfer capacity of a borehole, using mobile equipment, to determine the thermal properties of the entire borehole system such as thermal conductivity, diffusiveity. volumetric heat capacity, and borehole thermal resistance. The results from the response test include not only the thermal properties of the ground and the borehole, but also conditions that are difficult to estimate, e,g. natural convection in the boreholes, asymmetry in the construction, etc. In this study, 1) theoretical in situ methods for assessing working fluid temperature variation in V-type PE tube have been introduced, and 2) TRTE(Thermal Response Test Equipment) has been built based on these kinds of theoretical in situ methods. Basically TRTE consists of a pump, a heater and temperature sensors for measuring the inlet and outlet temperatures of the borehole. In order to make equipment easily transportable it is set up on a small trailer. Since the response test takes above two days to execute, the test was fully automatic in recording measured data using Labview DAS(Data acquisition system) program. The test was demonstrated in the course of intensive research in this field through the one site at Ulsan city in Korea. From this kind of thermal properties test of borehole systems in situ, the design of the borehole system can be optimized regarding the total geological, hydro-geological and technical conditions at the location.

  • PDF

다운홀 탄성파 기법용 전단파 자동 가진원의 개발 (Development of Automatic Shear-wave Source for Downhole Seismic Method)

  • 방은석;성낙훈;김정호;김동수
    • 한국지반공학회논문집
    • /
    • 제23권11호
    • /
    • pp.27-37
    • /
    • 2007
  • 지반의 전단파 속도 주상도를 도출하는데 있어 다운홀 기법은 하나의 시추공을 이용하고 간단한 지표면 가진원을 사용하므로 매우 경제적이다. 현장 실험을 더욱 용이하게 하고 양질의 신호를 획득하기 위해 자동 가진원을 개발하였다. 모터-스프링 타입으로 저렴하며 현장에서 다루기 매우 용이하다. 자동 가진원은 수동 가진원에 비하여 육체적 부담을 줄여주고 실험 소요 시간을 단축시킨다. 양질의 반복성이 있는 신호를 발생시켜 결과 해석에 유리하다. 자동 가진원과 더불어 적절한 감지기 시스템, 노트북 기반 신호 획득 장비 및 운용 프로그램과의 조합을 통해 반자동 다운홀 수행 시스템을 구축하였다. 수동 가진원과의 비교 검증 실험을 통해 제작된 자동 가진원의 장점들을 확인할 수 있었다. 또한, 구축된 수행 시스템의 현장 적용을 통해 용이하고 신뢰성 있는 기법 수행을 위해서 시스템을 자동화하는 것이 유리함을 알 수 있었다.

EFFECTS OF THE VEHICLE MODEL ON SHIFTING TRANSIENTS OF PASSENGER CARS WITH AUTOMATIC TRANSMISSION

  • Kong, J.H.;Park, J.H.;Lim, W.S.;Park, Y.I.;Lee, J.M.
    • International Journal of Automotive Technology
    • /
    • 제7권2호
    • /
    • pp.155-160
    • /
    • 2006
  • This paper presents a vehicle model for analyzing the transient shifting characterisitics of a passenger car with automatic transmission. Then the presented vehicle model was linked with the dynamic model of an automatic transmission. In order to identify the parameters of the vehicle model, we installed a test equipment with an accelerometer in a conventional vehicle and performed road tests. With the proposed vehicle model, we simulated the dynamic characteristics during shifting, and benchmarked with experimental results. Moreover, a modal analysis was carried out to investigate the effect of the vehicle model in the frequency domain and to obtain the transfer function of the vehicle model. In addition, we showed the numerical results in the time domain for analyzing the effect of each stiffness element, such as engine mountings and suspensions.

무인 착저식 해양 콘관입시험기 개발 (Development of Unmanned Seabed type Marine Cone Penetration Testing System)

  • 장인성;권오순;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.611-622
    • /
    • 2007
  • In the design and construction of the coastal/offshore structures, it is very important to evaluate the geotechnical characteristics of marine soils, which support the structures. Although the offshore site investigation is much more difficult than onshore, safe and precise jobs have not been accomplished in Korea because of the insufficiency of the test equipments especially for the site with deep water depth. The main objective of this study is to develop a new type of marine cone penetration testing(CPT) system, which can be utilized to even deep sea and high depth of soil layer. The system is one of seabed types and employs the conventional cone, which shows more reliable results than miniature cone. The most important parts of the marine CPT including continuous rod system, cone penetration system with wheel drive, automatic cone rod assembly/dissembly system etc., were designed and manufactured. Some tests to verify the developed marine CPT system were performed at both onshore and offshore sites as well as mechanical test in laboratory. The test results show the consistent and promising performance of the new equipment, and thereafter the system would be applicable to various sites with practical/economical advantages.

  • PDF

전자연동장치의 연동검사시스템 개발 (A Study on Development of Interlocking Inspection System for Electronic Interlocking System)

  • 박영수;이기서
    • 한국철도학회논문집
    • /
    • 제5권2호
    • /
    • pp.104-111
    • /
    • 2002
  • The purpose of interlocking system was to prevent the route for a train being set up and its protecting signal cleared if there was already another, conflicting route set up and the protecting signal for that route cleared. This paper proposed Interlocking Inspection System(IIS) consisting of interlocking simulator and field simulator to operate interlocking test of computer based Electronic Interlocking System(EIS) in this paper. Interlocking simulator consists of Design Edit System(DES), Logical Database Management Tool(LDMT) and real-time confirming system, field simulator is a equipment to simulate a control object of EIS and constitutes configuration operated in 19 inch standard rack. As a result of test to prove capacity of this IIS, the efficiency was shown as excellent. Therefore by using inspection system, we obtain every advantages. It has the functions for test data generation and automatic test execution based on personal computer. Time and cost for test work can be reduced more efficiently by using this developed inspection system

ESR 자동분석기를 이용한 내부정도관리방법 (The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate)

  • 조영국;심현설;송운흥;박규은
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

ATP 차상장치의 틸팅열차 설치 및 설치시험 분석 (Analysis of Tilting Train Installation and Installation Test for ATP(Automatic Train Protection) On-board Equipment)

  • 백종현
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2534-2540
    • /
    • 2010
  • 본 논문에서는 틸팅열차의 안전성 확보 및 운행효율 향상을 위해 “한국형 틸팅열차 신뢰성 평가 및 운용기술개발” 연구과제의 한 분야로 추진된 ATP 차상장치의 설치 및 시운전시험에 대한 내용 및 결과를 제시하고 있다. 한국철도기술연구원에서는 기존선의 속도 향상과 KTX 비수혜지역의 여객 서비스 향상을 위해 틸팅열차를 개발하였으며 개발된 틸팅열차의 신뢰성 평가를 위해 기존에 사용되고 있는 ATS 장치에 의한 10km 주행 시운전 시험을 진행하였다. 국토해양부에서는 KTX가 운행되지 않는 지역인 중앙선 및 충북선을 비롯한 7개 기존 노선을 200km/h 이상으로 고속화하기로 하였으며, 이에 따라 열차제어시스템은 기존의 ATS 장치에서 ATP 장치로 개량하여야 한다. 따라서 틸팅열차에도 ATP 차상장치를 설치하여 운행 적합성을 확인하여야 하기 때문에 한국철도공사의 경부선 및 호남선 ATP 구축사업에 사용된 것과 동일한 ATP 차상장치를 틸팅열차에 설치하여 시험하였다.