• Title/Summary/Keyword: Automatic switch

Search Result 119, Processing Time 0.044 seconds

Study of Drawing Optimum Switch Automation Rate to Minimize Reliability Cost (신뢰도 비용 최소화를 위한 개폐기의 최적 자동화율 도출에 관한 연구)

  • Chai, Hui-seok;Kang, Byoung-wook;Kim, Jin-seok;Moon, Jong-fil;Kim, Jae-chul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.297-302
    • /
    • 2015
  • Replacing a manual switch installed in a feeder for a distribution system with an automatic one increases the reliability of the electric power system. This is because the automatic switch can shorten the duration of a fault the customer experiences by splitting the faulty section faster than the manual one does. However, improving the reliability of the distribution system may increase investment costs. Here, the investment costs include automatic switch cost, replacement work cost and labor cost. For this reason, importance should be attached to the proper balance between the increase of the investment costs and the improvement of the reliability of the distribution system. This article analyzed reliability index and economics when manual switches installed in a feeder (RBTS Bus2 model) was replaced by automatic ones. In addition, it attempted to draw the optimum rate of automation of manual switches by automatic ones using the GRG optimization method, considering the current economic requirements.

A Report on Test Results of Pressure Operated Switch (압력스위치 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • s.12
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

An Automatic Synchronous Switch Post Regulator for Multi-Output Flyback Converter (다출력 플라이백 컨버터를 위한 자동 동기 스위치 포스트 레귤레이터)

  • Kim, Ho-Jin;Lee, Hai-Don;Yang, Seung-Uk;Mok, Hyung-Soo;Choe, Gyu-Ha;Lee, Soung-Ju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.321-327
    • /
    • 2006
  • In this paper, An Automatic Synchronous Switch Post Regulator for Multi-Output Flyback Converter is proposed. The proposed circuit is composed simply using a new automatic synchronous switch instead of conventional complex Switch Post Regulator owing to difficulty of drive circuit materialization and synchronization between main output and auxiliary output. By using the proposed circuit, we can make simple and inexpensive Multi-Output Converter with variable and accurate output voltage and proved adequacy of proposed circuit through experiment, simulation and theoretical analysis.

Suggestion of Photovoltaic Switch and Evaluation of Its Usability (태양광 스위치 제안 및 효용성 평가)

  • Jang, Junho;Lee, Junho;Jeong, Juhwan;Jang, Minseok;Lee, Yonsik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.9
    • /
    • pp.33-41
    • /
    • 2013
  • In this paper, a photovoltaic switch is suggested that is operated by solar module, a substitute for CdS(Cadmium Sulfide) of most existing automatic switches and thus is powered by its renewably charged battery, and its usability is investigated through various experiments. At first the characteristics of CdS and the operation principle of the existing automatic switch are investigated, and then the characteristics of solar module are examined. These preparatory research shows the possibility of substitution of solar module instead of CdS in light activated switch. Secondly the suggested photovoltaic switch's circuit is designed, implemented and then its experimental comparison data shows the possibility for the replacement of the existing switch to the suggested switch, and furthermore its superiorities.

Study on the algorithm for the Reasonable Switch Automation Rate with Customer Interruption Cost and Reliability Evaluation (정전비용과 신뢰도 분석을 통한 분할 개폐기의 적정 자동화율 도출 알고리즘에 관한 연구)

  • Chai, Hui-Seok;Shin, Hee-Sang;Cho, Sung-Min;Moon, Jong-Fil;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.467-473
    • /
    • 2013
  • The addition of disconnect switches to a distribution feeder or the replacement of the manual switches with the automatic switches do, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder and reducing the outage section. However, the improvement of reliability in power distribution system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we suggest the algorithm for determining the reasonable switch automation rate in the power distribution system. We evaluate the customer interruption cost and reliability for several cases - these cases relate with the switch automation rate - in the domestic metropolitan power distribution system, estimate the effectiveness of changing the manual switch to automatic switch quantitatively. These results can help the determining on the disconnect switch's automation rate.

A Technical Trend on Automatic Vacuum Capacitor Switch with Modified Digital Filter Design (디지털 필터 설계를 이용한 자동 진공 콘덴서 스위치의 기술 동향)

  • Oh, Gi-Soo;Chang, Young-Ho;Yun, Ju-Ho;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1978-1979
    • /
    • 2007
  • In this paper, the authors introduce a high-speed microprocessor based on automatic vacuum capacitor switch with a modified digital filter design using distributed arithmetic. The automation trends particularly the automatic vacuum capacitor switch has helped ameliorate the power factor essentials and automatically triggered to close when the line current exceeds rated value. Microprocessor relays use digital filters to extract only the fundamental and attenuate harmonics. To provide optimum speed characteristics a distributed arithmetic based filter design in the microprocessor controller which not only enhances filtering speed but additionally enables lower power consumption at the cost of area has been introduced. The result is a unified description that describes a digital filter structure down to bit level.

  • PDF

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I) (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I))

  • Kim, C.S.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.2
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

Analysis of Distribution Line Sectionalizing Effects for The Probable Distribution System Configuration (적정 배전계통 구성을 위한 선로분할 효과 분석)

  • Kim, J.H.;Ha, B.N.;Nam, K.Y.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.86-89
    • /
    • 1993
  • This paper contains the various effect of distribution feeder sectionalizing by distribution automation. The effect by automatic sectionalizing switch and the effect by manual switch are analyzed and shown according to the radial feeder and the loop feeder respectively. Based on the reliability analysis, the reference for the feeder division and sectionalization is recommended. Also, the necessary number of manual switch where the automatic switch is installed is recommended through the reliability analysis.

  • PDF

Automatic Switching of Clustering Methods based on Fuzzy Inference in Bibliographic Big Data Retrieval System

  • Zolkepli, Maslina;Dong, Fangyan;Hirota, Kaoru
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.4
    • /
    • pp.256-267
    • /
    • 2014
  • An automatic switch among ensembles of clustering algorithms is proposed as a part of the bibliographic big data retrieval system by utilizing a fuzzy inference engine as a decision support tool to select the fastest performing clustering algorithm between fuzzy C-means (FCM) clustering, Newman-Girvan clustering, and the combination of both. It aims to realize the best clustering performance with the reduction of computational complexity from O($n^3$) to O(n). The automatic switch is developed by using fuzzy logic controller written in Java and accepts 3 inputs from each clustering result, i.e., number of clusters, number of vertices, and time taken to complete the clustering process. The experimental results on PC (Intel Core i5-3210M at 2.50 GHz) demonstrates that the combination of both clustering algorithms is selected as the best performing algorithm in 20 out of 27 cases with the highest percentage of 83.99%, completed in 161 seconds. The self-adapted FCM is selected as the best performing algorithm in 4 cases and the Newman-Girvan is selected in 3 cases.The automatic switch is to be incorporated into the bibliographic big data retrieval system that focuses on visualization of fuzzy relationship using hybrid approach combining FCM and Newman-Girvan algorithm, and is planning to be released to the public through the Internet.