• Title/Summary/Keyword: Automatic separation

Search Result 105, Processing Time 0.035 seconds

A Study on the Implementation of Robust Automatic Adaptative Chroma-key Method (자동 적응성 동적 크로마키 구현에 관한 연구)

  • Lee, Sang-Yeob;Joo, Heon-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • The man who wants to create advance user created contents Is in need of using chroma-key method in a certain environment. Recently. pavilion that is painted with mono-color is used for the application of chroma-key. This paper aims to introduce a robust automatic adaptive chroma-key method without using pavilion. In this research. a new chroma-key method is applied to the separation of high frequency and low frequency using Wavelet is done in order that the noise can be eliminated. As a result, a chroma-key method with good capacity is shown from the research.

  • PDF

Automatic Conversion of Machining Data by the Feature Recognition of Press Mold (프레스 금형의 특징형상 인식에 의한 가공데이타 자동변환)

  • Choi, Hong-Tae;Bahn, Kab-Soo;Lee, Seok-Hee
    • IE interfaces
    • /
    • v.7 no.3
    • /
    • pp.181-191
    • /
    • 1994
  • This paper presents an automatic conversion of machining data from the orthographic views of press mold by feature recognition rule. The system includes following 6 modules : separation of views, function support, dimension text check and feature processing modules. The characteristic of this system is that with minimum user intervention, it recognizes basic features such as holes, slots, pockets and clamping parts and thus automatically converts CAD drawing details of press mold into machining data using 2D CAD system instead of using an expensive 3D Modeler. The system is developed by using IBM-PC in the environment of AutoCAD R12, AutoLISP and MetaWare High C. Performance of the system is verified as a good interfacing of CAD and CAM when applied to a lot of sample drawing.

  • PDF

The Analysis of Free Amino Acids in Tobacco (잎담배 중 유리 아미노산 분석)

  • Lee, Jeong-Min;Min, Hey-Jung;Jang, Gi-Chul;Hwang, Keon-Joong
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.32 no.2
    • /
    • pp.70-76
    • /
    • 2010
  • A simple and sensitive automatic amino acid analyzer method for the determination of free amino acids in tobacco was described. Sample preparation consisted of a single step of extraction with 0.1 mol HCl at ambient temperature in 60 min by sonication, followed by filtration of an aliquot. Automated amino acid analyzer was used to construct a post-column ninhydrin reaction unit to monitor amino acids separated by liquid chromatography using a series of eluting buffers. By optimization of sample preparation, separation of 19 amino acids was achieved. Limits of quantitation was 0.01 mg/g, coefficients of variation ranged from 0.5 % to 8.9 % and recoveries range from 85 % to 106 %. The method was applied to the analysis of amino acids contents of tobacco leaves in different varieties.

Semi-Automatic Hydride Generation and Atomic Absorption Determination of Bismuth with in situ Concentration in a Graphite Furnace

  • Yong-Keun Lee;Dong Soo Lee;Byung Mok Yoon;Hoon Hwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.290-295
    • /
    • 1991
  • A semi-automatic method for the determination of dissolved bismuth at parts per trillion levels is described. The method involves bismuthine generation, in situ collection of bismuthine in a graphite furnace, and atomic absorption detection. In order to facilitate semi-automation of bismuthine generation and separation from aqueous solution, Gore-tex microporous PTEE membrane is used. The absolute detection limit, taken as three times the standard deviation of the instrument noise is 2 pg. The precisions are 3.1% for 100 pg and 1.9% for 1 ng of bismuth, respectively. As many as 90 measurements can be made in an hour.

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Evaluation of Polishing Performance Using The Improved Polishing Robot System Attached to Machining Center (머시닝센터 장착형 연마로봇의 성능 향상 및 연마 성능 평가)

  • Lee, Min-Cheol;Cho, Young-Gil;Lee, Man-Hyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.9
    • /
    • pp.179-190
    • /
    • 1999
  • To automate the polishing process, a polishing robot with two axes which is attached to a machining center with three axes has been developed by our previous research. This automatic polishing robot is able to keep the polishing tool normal to the curved surface of die and is able to maintain a constant pneumatic pressure. Therefore, in the case of a curved surface die, the surface roughness to be polished by the system with five axes is improved superior than the surface by a three-axis machining center. However, because the polishing robot was big and heavy, a polishing workspace was limited and then it was difficult to attach the robot to machining center. In this study, the smaller and lighter polishing robot than the previous has been designed to improve defects due to the magnitude and weight of the robot. And the sliding mode control ins applied to polishing robot to improve the tracking performance. To obtain switching parameters of sliding mode control, the signal compression method is used. Code separation program to separate the date for a three-axis machining center and a two-axis polishing robot from a five-axis NC data is improved for users to check conveniently the separated trajectory and to handle many data by using the graphic user interface. To evaluate the polishing performance of the developed robot, the polishing experiment for shadow mask was carried out. The result shows the automatic polishing robot has a good trajectory tracking performance and obtains a good polished workpiece efficiently under recommended polishing conditions.

  • PDF

Underdetermined Blind Source Separation from Time-delayed Mixtures Based on Prior Information Exploitation

  • Zhang, Liangjun;Yang, Jie;Guo, Zhiqiang;Zhou, Yanwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2179-2188
    • /
    • 2015
  • Recently, many researches have been done to solve the challenging problem of Blind Source Separation (BSS) problems in the underdetermined cases, and the “Two-step” method is widely used, which estimates the mixing matrix first and then extracts the sources. To estimate the mixing matrix, conventional algorithms such as Single-Source-Points (SSPs) detection only exploits the sparsity of original signals. This paper proposes a new underdetermined mixing matrix estimation method for time-delayed mixtures based on the receiver prior exploitation. The prior information is extracted from the specific structure of the complex-valued mixing matrix, which is used to derive a special criterion to determine the SSPs. Moreover, after selecting the SSPs, Agglomerative Hierarchical Clustering (AHC) is used to automaticly cluster, suppress, and estimate all the elements of mixing matrix. Finally, a convex-model based subspace method is applied for signal separation. Simulation results show that the proposed algorithm can estimate the mixing matrix and extract the original source signals with higher accuracy especially in low SNR environments, and does not need the number of sources before hand, which is more reliable in the real non-cooperative environment.

Determination of $^{241}$Am and $^{241}$Cm in Radwaste Samples (방사성폐기물 시료 중 $\^{241}$Am과 $\^{244}$Cm의 정량)

  • Joe Kih Soo;Kim Tae Hyun;Jeon Young Shin;Jee Kwsng Yong;Kim Won Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Anion exchange chromatography and HDEHP extraction chromatography using DTPA-lactic acid as an eluent were applied in series for the separation of $^{241}$Am and $^{244}$Cm in radwaste samples. The separated elements were determined by electrodeposition at the sodium hydrogen sulfate-sodium sulfate buffer solution followed by alpha-spectrometry. The recovery yields of $^{241}$Am and $^{244}$Cm were 85.2$\pm$$15.3\%$, respectively, from the synthetic solution of spent nuclear fuel sample. The amounts of 241Am and 2440m determined in radwaste sample solutions of condensate bottoms were at the range of 1.5-1.9 Bq/g and -1.7 Bq/g, respectively.

  • PDF

Automatic Parameter Estimation Considering Runoff Components on Tank Model (유출성분을 고려한 Tank 모형의 매개변수 자동추정)

  • Bae, Deg-Hyo;Jeong, Il-Won;Kang, Tae-Ho;Noh, Joon-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.423-436
    • /
    • 2003
  • The objective of this study is to propose an automatic parameter estimation scheme considering runoff components of Tank model. It estimates model parameters by Powell's automatic algorithm based on the runoff component separation of the observed hydrograph by using digital filter method. The selected study areas are the 4 main dam sites on the Han River. The simulated flows are compared with the observed flows depending on whether runoff component consideration or not. As a result, the estimated model parameters from classical Powell's method only can relatively well simulate the time variation of total runoff, but gives poor runoff component simulations. Therefore, it can be concluded that the proposed automatic parameter estimation scheme in this study Is more reliable and objective.

Development of Automatic Sorting System for Black Plastics Using Laser Induced Breakdown Spectroscopy (LIBS) (LIBS를 이용한 흑색 플라스틱의 자동선별 시스템 개발)

  • Park, Eun Kyu;Jung, Bam Bit;Choi, Woo Zin;Oh, Sung Kwun
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.73-83
    • /
    • 2017
  • Used small household appliances have a wide variety of product types and component materials, and contain high percentage of black plastics. However, they are not being recycled efficiently as conventional sensors such as near-infrared ray (NIR), etc. are not able to detect black plastic by types. In the present study, an automatic sorting system was developed based on laser-induced breakdown spectroscopy (LIBS) to promote the recycling of waste plastics. The system we developed mainly consists of sample feeder, automatic position recognition system, LIBS device, separator and control unit. By applying laser pulse on the target sample, characteristic spectral data can be obtained and analyzed by using CCD detectors. The obtained data was then treated by using a classifier, which was developed based on artificial intelligent algorithm. The separation tests on waste plastics also were carried out by using a lab-scale automatic sorting system and the test results will be discussed. The classification rate of the radial basis neural network (RBFNNs) classifier developed in this study was about > 97%. The recognition rate of the black plastic by types with the automatic sorting system was more than 94.0% and the sorting efficiency was more than 80.0%. Automatic sorting system based on LIBS technology is in its infant stage and it has a high potential for utilization in and outside Korea due to its excellent economic efficiency.