• Title/Summary/Keyword: Automatic restoration

Search Result 62, Processing Time 0.054 seconds

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

A Method for Restoring Trademark and Caption Areas using Isophote Information (등광도선 정보를 이용한 상표 및 자막영역 복원 방법)

  • 김종배;정수웅
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.1-8
    • /
    • 2004
  • In this paper, we propose a method for restoring trademark and caption areas using an isophote. In our method, the image restoration problem is modeled as an optimization problem, which in our case, is solved by a cost function with isophote constraint that is minimized using a GA The technique creates an optimal connection of all pairs of isophotes disconnected by a caption in the frame. For connecting the disconnected isophotes, we estimate the value of the smoothness, given by the best chromosomes of the GA and project this value in the isophote direction. Experimental results show that the isophote operator worked better than Laplacian operator for image restoration, and the proposed method has a great possibility for automatic restoration of a region in an advertisement scene.

Spatiotemporal Changes of the Thermal Environment by the Restoration of an Inner-city Stream (도시 내부 하천 복원에 의한 열 환경의 시공간적 변화)

  • Kwon, Tae Heon;Kim, Kyu Rang;Byon, Jae-Young;Choi, Young-Jean
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.321-330
    • /
    • 2009
  • Spatiotemporal changes in the thermal environment in a large city, Seoul, Korea were analyzed using a thermal index, perceived temperature (PT), to standardize the weather conditions. PT is a standard index for the thermal balance of human beings in thermophysiological environment. For the analysis of PT, the data from long-term monitoring and intensive observations in and around the inner-city stream called 'Cheonggye' in Seoul, were compared with a reference data from the Seoul weather station. Long-term data were monitored by installing two automatic weather stations at 66m (S1) and 173m (S2) away from the center of the stream. Through the analysis of the data during the summer of 2006 and intensive observation periods, it was revealed that the stream's effects on the PT extended up to the distance of the S1 site. In winter, the increase of the PT between pre- and post-restoration was stronger at S1, which was nearer than S2 from the stream. These results suggest that PT can be used as an effective model in analyzing the changes of the thermal environment in relation with the changes of water surface areas.

COMPUTERIZED CALL RESPONSE SYSTEM DEVELOPMENT AND OPERATION FOR DISTRIBUTION SERVICES (전기고장접수 처리 자동화장치 개발운용)

  • Lee, Yong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.265-269
    • /
    • 1989
  • Computerized to techniques have been applied to outage call processing system for rapid restoration of power to customers. This paper presents computer aided outage call processing system called '123' system, which has been in operation since 1987. And, also describes its origins, design conception to be considered and its operation effects. From a positive point of view, it shows the functions needs to be added and some problems to be improved. Additionally, it describes the integrated system which has functions of detecting distribution failure, locating failure position by logical computer processing, and although ADS (Automatic Distribution System) has yet to be built up, the primary purpose of the system is to improve service to the customer by means of rapid restoration of electricity outage.

  • PDF

Protection and Restoration of GMPLS LSP using CR-LDP Detours (CR-LDP 우회를 통한 GMPLS LSP의 보호 및 복구)

  • 김진형;정재일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12B
    • /
    • pp.1051-1059
    • /
    • 2003
  • The key feature of GMPLS is the provision of network resources and the automatic set-up of a path. And the mechanism of protection and restoration of a path is presented when network component fails. This paper suggests CR-LDP Static Detour Mechanism and Dynamic Detour Mechanism. CR-LDP Detours are a mechanism to set up detour paths automatically at every node to protect working path. Hence suggested mechanism performance is compared with existing mechanisms by computer simulation.

An Hardware Error Analysis of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Surface Reconstruction (3차원 안면자동인식기(3D-AFRA)의 Hardware 정밀도 검사 : 형상복원 오차분석)

  • Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Jun-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.30-39
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitution. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So we should examine the figure restoration error of 3D Automatic Fare Recognition Apparatus(3D-AFRA) in hardware Error Analysis. 2. Methods We scanned Face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And also we scanned Face status by using laser scanner(vivid 9i). We compared facial shape data be restored by 3D Automatic Face Recognition Apparatus(3D-AFRA) with facial shape data that be restorated by 3D laser scanner. And we analysed the average error and the maximum error of two data. 3. Results and Conclusions In frontal face, the average error was 0.48mm. and the maximum error was 4.60mm. In whole face, the average error of was 0.99mm. And the maximum error was 6.64mm. In conclusion, We assessed that accuracy of 3D Automatic Face Recognition Apparatus(3D-AFRA) is considerably good.

  • PDF

Development of Automatic Power Restoration System And Operation in KEPCO Real Power System (정전자동복구시스템의 개발 및 한전 실계통 적용)

  • Hong, Soon-Chun;Choo, Jin-Boo;Lee, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.49-51
    • /
    • 2001
  • Recently, according to a rapid increase of the power demand, the KEPCO's 154kV lines are continuously expanded and become to the more complex loop system. As a result of increase of the fault capacity and the unbalance of power load flow, the circuit breaker have been exceeding the capacity limit of those in the loop power system. To solve this problem, APRS application will be necessary more and more.

  • PDF

Urban Heat Islands in Seoul during the Summertime of 2003 (2003년 여름철 서울의 도시열섬)

  • Kim Yeon-Hui;Eom Hyang-Hui;O Seong-Nam;Kim Sang-Baek
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.503-503
    • /
    • 2003
  • Urban heat islands related with Cheongyecheon restoration in Seoul metropolitan area for the summertime of 2003. To investigate the spatial and temporal structure of the urban heat island in Seoul, temperature data measured at 32 automatic weather stations (AWSs) in the Seoul metropolitan area and 12 additional stations operated by the portable device for the measurement of temperature and relative humidity in the Cheonggyecheon area. (omitted)

  • PDF

The Application of ASTER TIR Satellite Imagery Data for Surface Temperature Change Analysis -A Case Study of Cheonggye Stream Restoration Project- (도시복원사업의 열 환경 변화 분석을 위한 ASTER 열적외 위성영상자료의 활용 -청계천 복원사업을 사례로-)

  • Jo, Myung-Hee;Jo, Yun-Won;Kim, Sung-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.12 no.1
    • /
    • pp.73-80
    • /
    • 2009
  • Recently in order to mange better life quality much effort was spent for environmental-friendly urban development project and environmental restoration project. During these projects, there should be deep understanding about atmospheric environment change analysis and long term monitoring so that it would be helpful for better environment promotion such as heat island mitigation effect and wind way construction. In this study, the surface temperature environment change between before and after Cheonggye Stream Restoration Project was mapped and analyzed by using ASTER(Advanced Spaceborne Thermal Emission Reflection Radiometer) TIR(Thermal Infrared) satellite imagery and finally the fact, that the heat island effect was mitigated, was clarified. For this study, the correlation analysis was conducted through comparing the difference between atmosphere temperature of AWS(Automatic Weather System) and surface temperature of ASTER. Furthermore, this study will be the infrastructure of urban meteorology model development by understanding surface temperature pattern change and executing quantitative analysis of heat island.

  • PDF