• 제목/요약/키워드: Automatic power control

검색결과 570건 처리시간 0.033초

Electrical Engineering Design Method Based on Neural Network and Application of Automatic Control System

  • Zhe, Zhang;Yongchang, Zhang
    • Journal of Information Processing Systems
    • /
    • 제18권6호
    • /
    • pp.755-762
    • /
    • 2022
  • The existing electrical engineering design method and the dynamic objective function in the application process of automatic control system fail to meet the unbounded condition, which affects the control tracking accuracy. In order to improve the tracking control accuracy, this paper studies the electrical engineering design method based on neural network and the application of automatic control system. This paper analyzes the structure and working mechanism of electrical engineering automation control system by an automation control model with main control objectives. Following the analysis, an optimal solution of controllability design and fault-tolerant control is figured out. The automatic control power coefficient is distributed based on an ideal control effect of system. According to the distribution results, an automatic control algorithm is based on neural network for accurate control. The experimental results show that the electrical automation control method based on neural network can significantly reduce the control following error to 3.62%, improve the accuracy of the electrical automation tracking control, thus meeting the actual production needs of electrical engineering automation control system.

저 출력시 증기발생기 수위의 자동제어논리 개발 (Development of an automatic steam generator level control logic at low power)

  • 한재복;정시채;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.601-604
    • /
    • 1996
  • It is well known that steam generator water level control at low power operation has many difficulties in a PWR (pressurized water reactor) nuclear power plant. The reverse process responses known as shrink and swell effects make it difficult to control the steam generator water level at low power. A new automatic control logic to remove the reverse process responses is proposed in this paper. It is implemented in PLC (programmable logic controller) and evaluated by using test equipment in Korea Atomic Energy Research Institute. The simulation test shows that the performance requirements is met at low power (below 15%). The water level control by new control logic is stabilized within 1% fluctuation from setpoint, while the water level by YGN 3 and 4 control logic is unstable with the periodic fluctuation of 25% magnitude at 5% power.

  • PDF

심야전력의 효율적 운영을 위한 공급시간 자동제어시스템의 개선 (Improvement of Automatic control system for midnight power to operate effectively)

  • 문식;최길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.846-848
    • /
    • 2005
  • Midnight electrical power appliance has come into a wide use due to the midnight power rate system introduced for effective power operation and an improved load factor. However, the sharply increased number of the appliance has brought about a serious problem in midnight power supply for the past few years. Moreover, the automatic control device, developed to address the problem, has not properly functioned because of the misusage and illegal conversion of the device. This paper will suggest solutions to the problem by improving the automatic control system for supply time (ACST) and demonstrate its effectiveness through tests.

  • PDF

트랙터 8단 자동변속기 기어 열 설계 (Gear Train Design of 8-Speed Automatic Transmission for Tractor)

  • 정규홍
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권2호
    • /
    • pp.30-36
    • /
    • 2013
  • Tractor is a farm vehicle that is designed to provide a high tractive effort at low speed. It is used for versatile agricultural tasks such as hauling a trailer, tillage, mowing and construction work. Most older tractors use a manual transmission. However, as the intensity of work increases, tractors equipped with automatic transmission become popular due to the work convenience. In order to give the operator a large degree of control in field work, 24 gears with automatic 8-speed and manual 3-speed are arranged in transmission. This paper deals with the gear train that is designed for 8-speed automatic transmission by the engagement of multi-disk clutches. The gear ratio for each speed as well as power transmission mechanism is analyzed through velocity analysis. In addition, constraints of mesh gear ratio are derived by investigating the power flow path in velocity diagram for the given 8-speed gear ratio.

공작기계용 공작물 자동 적재장치의 제어장치 설계 및 제작 (Design and Manufacture of a Machine Tool Control System for Workpiece Automatic Loading System)

  • 안준환;김갑순
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.62-68
    • /
    • 2019
  • In this paper, we describe the design and manufacture of a control system for an automatic loading system that inserts and removes workpieces after machining. The control system was manufactured using DSP for high speed and consists of a power unit, a control unit, a communication unit, and a display unit. We connected the control system to the mechanical system of the automatic workpiece loader to test the characteristics, which allowed us to raise and lower the automatic workpiece loading system to the desired position. The successful test demonstrates that we can use the control system to control the workpiece automatic loading system.

무인발전소 SCADA SYSTEM 에서의 AQR 제어 운영 (The AQR Control in the SCADA System of Manless Power Plant)

  • 옥연호;이은웅;변일환;김기원;오석영;최형철;이남형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.58_59
    • /
    • 2009
  • Generator excitation system, supplying the voltage to power system, is controlled by various manners as aspects of power system. Previously excitation systems mainly used AVR(Automatic Voltage Regulator) and FCR(Field Current Regulator) to control voltage, but nowadays the excitation systems have the tendency to adopt AQR(Automatic Reactive power Regulator) and APFR(Automatic Power Factor Regulator) to do it so as to get into step with diverse requirements of power system and high digital technology. This paper presents which operation methods is effective for the equipment, according to increase the unmanned power station thanks to automation technic.

  • PDF

마크 밀도 변화에 강한 버스트 모드 자동 전력 제어 회로 (A Burst-mode Automatic Power Control Circuit Robust io Mark Density Variations)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제41권4호
    • /
    • pp.67-74
    • /
    • 2004
  • 기존의 버스트 모드 자동전력제어 회로는 데이터 율이 증가함에 따라 마크밀도 변화 영향을 심하게 받아 에러를 야기하였다. 이 문제를 해결하기 위해 높은 데이터 율에서도 마크밀도의 영향을 배제시킬 수 있는 새로운 구조의 첨두 비교기를 고안하고 이를 자동전력제어 회로에 적용하여 마크밀도 변화에 강한 버스트 모드 자동전력제어 회로를 제안하였다. 제안한 자동전력제어 회로 내의 첨두 비교기는 높은 데이터 율에서 뿐만 아니라 광범위한 기준전류 및 차 전류 변화에서도 미소한 마크밀도 변화 영향만을 보여 마크밀도 변화에 매우 강한 특성을 확인 할 수 있었다.

Optimization of automatic power control of pulsed reactor IBR-2M in the presence of instability

  • Pepelyshev, Yu.N.;Davaasuren, Sumkhuu
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2877-2882
    • /
    • 2022
  • The paper presents the main results of computational and experimental optimization of the automatic power control system (AC) of the IBR-2M pulsed reactor in the presence of a high level of oscillatory instability. Optimization of the parameters of the AC made it possible to significantly reduce the influence of random and deterministic oscillations of reactivity on the noise of the pulse energy, as well as to sharply reduce the manifestation of the oscillatory instability of the reactor. As a result, the safety and reliability of operation of the reactor has increased substantially.

화력발전소 부하조절기 자동추동장치에 의한 계통주파수 개선에 관한 연구 (Improvement in Power System Frequency Control by Automatic Follow-up Regulator of Thermal Power Plant)

  • 권욱현;황재호
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.10-17
    • /
    • 1991
  • An improved control method in turbine control system is proposed. By automatic follow-up design, power system frequency may be maintained within prespecified range. Base or half load control is possible by distributing power plant load allotment. Otherwise, diminutive frequency-load control is dine by governor-free operation in power plant. This paper proposes governor-free operation which is automatically followed by load-limitter setter. The condition which limits governor action may be somewhat improved within boiler condition by this idea. This design has been implemented at Samchunpo thermal power plant. The improved practical results are shown.

  • PDF

Diagnostic and Active Filtering of Harmonics Generated by Compact Fluorescent Lamps

  • Moulahoum, Samir;Houassine, Hamza;Kabache, Nadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 2014
  • Use of nonlinear loads, such as power converters, fluorescent lamps and adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents. This paper presents the active filtering of the harmonic distortion generated by the compact fluorescent lamps (CFL). The Instantaneous active and reactive power theory (the p-q Theory) is used to design the control of parallel active filter. The control scheme has been verified using Matlab/Simulink with SimPower Systems through a set of simulation tests under different load conditions. Also, the tuning of the active power filter is performed to improve the quality of the electrical power supply.