• 제목/요약/키워드: Automatic heating

검색결과 106건 처리시간 0.032초

Abnormal Coating Buildup on Si Bearing Steels in Zn Pot During Line Stop

  • Weimin Zhong;Rob Dziuba;Phil Klages;Errol Hilado
    • Corrosion Science and Technology
    • /
    • 제23권2호
    • /
    • pp.83-92
    • /
    • 2024
  • A hot-dip simulator was utilized to replicate abnormal coating buildup observed during line stops at galvanize lines, assessing the influence of processing conditions on buildup (up to 14 mm/side). Steel samples from 19 coils (comprising IF, BH, LCAK, HSLA, DP600-DP1180, Si: 0.006 - 0.8 wt%, P: 0.009 - 0.045 wt%) were examined to explore the phenomenon of heavy coating growth. It was discovered that heavy coating buildup (~3 mm/h) and rapid strip dissolution (~0.17 mm/h) in a GA or GI pot can manifest with specific combinations of steel chemistry and processing conditions. The results reveal the formation of a unique coating microstructure, characterized by a blend of bulky Zeta crystals and free Zn pockets/networks due to the "Sandlin" growth mechanism. Key variables contributing to abnormal coating growth include steel Si content, anneal temperature, dew point in heating and soaking furnaces, Zn pot temperature, Zn bath Al%, and cold-rolling reduction%. At ArcelorMittal Dofasco galvanize lines, an automatic online warning system for operators and special scheduling for incoming Si-bearing steels have been implemented, effectively preventing further heavy buildup occurrences.

Development of a prototype TL/OSL reader for on-site use in a large-scale radiological accident

  • Hyoungtaek Kim;Chang-Young Park;Sang In Kim;Min Chae Kim;Jungil Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2113-2119
    • /
    • 2024
  • This study presents the development and characterization of a prototype TL/OSL reader for the retrospective dose assessment of individuals in radiological emergencies. The reader is portable, semi-automatic, and capable of accurate measurements. The dimension of the reader is 25 × 25 × 37 cm3 and the weight is about 15 kg. The reader consists of a sample moving stage, a heating module, an optical stimulation module, a detection module, a data acquisition (DAQ) unit, a nitrogen gas control module, and a PC with a GUI program. The reader has three measurement modes: TL, CW_OSL, and custom mode. The reader was characterized using commercial thermal luminescence dosimeters (TLD, LiF:Mg,Cu,Si) and optically stimulated dosimeters (OSLD, Al2O3:C), as well as fortuitous materials, such as display glasses and resistors of mobile phone. The results showed that the reader is capable of measuring signals with a detection limit of up to 0.02 mGy using a commercial dosimeter. In the dose recovery test using fortuitous materials, the reconstructed doses obtained three days post-irradiation closely aligned with the initially administered doses. As a result, this study suggests that the developed TL/OSL reader is a promising instrument for emergency dose assessment at accident sites.

에너지 절감형 항온항습기 운전 특성에 관한 연구 (Study on the energy-saving constant temperature and humidity machine operating characteristics)

  • 차인수;하민호;정경환
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.27-33
    • /
    • 2016
  • 본 연구에서 적용한 열회복 방식은 적은 동력사용으로 최대의 냉각능력을 낼 수 있는 에너지 절약형이다. 항온항습기의 온습도를 보다 정밀 한 제어 기능을 갖도록 하기 위해 제어 알고리즘은 퍼지 PID 제어기를 설계하여 적용하였고, 외기보상장치(공냉식)를 갖추어 동절기에 $-20^{\circ}C$에서도 우수한 제습능력을 발휘하게 하였다. 고효율, 저소음형 시로코 팬을 채용하여 정숙운전이 되며 장비특성에 따라 상향식과 하향식에 맞도록 설계하였다. 실험한 결과 변환 효율은 95%이상, 정전복귀는 5sec 이내, 정지지연은 30sec 이내, 펌프다운은 10sec, 펌프지연은 5sec, 히팅지연은 5sec, 온도편차는 ${\pm}2^{\circ}C$(냉방편차: $2^{\circ}C$, 난방 편차: $2^{\circ}C$), 습도편차는 ${\pm}5%$(가습편차 3.0%, 제습편차 3.0%)을 갖게 하였다. 최근 유비쿼터스 기술이 중요시 되고 있기에 핸드폰을 통해 항온항습기를 원격 제어 할 수 있도록 하였고, MMI 소프트웨어와 자동 인터페이스를 지원하여 확장성이 뛰어나게 하였다. 또한 지능형 컨트롤러 고장진단에 의한 부품 및 장비의 수명이 연장 되도록 하였다.

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(III) -양지붕형 하우스의 창 개방방법에 따른 온.습도의 변화- (A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house-)

  • 김진현;김철수;구건효;이기명
    • Journal of Biosystems Engineering
    • /
    • 제20권2호
    • /
    • pp.162-172
    • /
    • 1995
  • The ventilation in greenhouse have been important for such as adjustment of temperature, supplying of the oxygen, prevention of the overhumidity, density adjustment of $CO_2$, discharge of harmfulness gas, etc. However, the general ventilation which had been used the quantitative control method in discharge of a property of air mechanism in greenhouse, and caused mainly in waste of the heating energy and growth obstacle of the vegetable. Therefore, this study was peformed to obtain more scientific ventilation method using by analysis and measurement of the isothermal lines according to opening of window ventilation in greenhouse, and the results are summarized as follows. 1. The ventilating amount was more influenced by rather opening amount of window than the ventilating time. 2. In window ventilation, the temperature in greenhouse was mostly changed within 5 minutes after ventilating not regard to the spot of opening, after about 10 minutes temperature became to equilibrium state under the respective ventilating conditions. 3. In opening of the skylight only, isothermal lines were complicated, therefore, a tall vegetable may be possible to damage by a cold-weather from the lower central port in greenhouse. 4. Isothermal lines were a tendency to simply in opening of a side window that may be more effective ventilation in kinds of the short vegetable. 5. In conditions of internal temperature>setting temperature>external temperature, a skylight can be suitable to open 10~20cm in order to the optimum ventilation in greenhouse. 6. In conditions of internal temperature>external temperature>setting temperature, opening of all the windows or both the side windows that can be suitable in order to obtain the optimum ventilation in greenhouse. 7. An effect of ventilation was the most excellent to open of all the windows or both the side windows, and it were also found orderly excellent to open of the side window and the skylight or the skylight only, to open of the side window only. 8. Temperature was varied as the equation of T=Tc+ (To-Tc)e-at, and the ranges of (a) values were limited within 0.34~0.68. 9. A variations of humidity were similar to that of temperature, s.

  • PDF

정밀 강설량계 개발을 위한 연구 (A Study on the Development of a High Resolution Snow Gauge)

  • 이부용
    • 한국농림기상학회지
    • /
    • 제8권4호
    • /
    • pp.270-274
    • /
    • 2006
  • 본 연구에서 고안 설계한 적설 관측용 수위 센서는 야외에서 일 변화량은 0.1 mm 내외의 적은 양의 오차를 기록하여 강설관측 센서로 적합한 것으로 판명되었으며, 실내 검정 결과 기상청에서 요구하고 100 mm의 강수 검정범위에 대해서 1%이하의 신뢰성 있는 검정결과를 나타내어 강설량 관측에 적합한 것으로 판명되었다. 또한 $-20^{\circ}C$의 테스트에서도 0.1 mm에 해당하는 아주 작은 변화 값을 타나내어 겨울철 야외환경에도 적합한 것으로 판명되었다. 깔때기가 없으며 수수구의 크기에 제한을 받지 않는 새로운 강수 관측구조는 적은 양의 강설관측이 가능하여 겨울철 예보에 필요한 레이다. 영상과 위성 영상에 의한 강설 연구와 해석에 많은 도움을 줄 수 있을 것이다. 또한 적설상당수량 관측이 가능하여 수자원 분야의 연구에도 많은 도움이 될 수 있다. 부동액을 사용하므로 고체 상태의 강설에 대해서 직접 관측이 가능하여 강설 관측에 있어 문제점으로 지적이 되고 있는 신적설 관측의 어려움을 해결할 수 있으며, 추후 야외 관측용 모델을 제작하여 야외 환경에서 여타 장비들과 비교 실험을 통해서 성능을 검정하고 개선할 계획이다.

대규모 도시개발사업에 대한 대기질 평가 사례 연구 (A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development)

  • 김상목;이상훈;박근형;우재균;구윤서;김성태;한진석
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.

위성 및 AWS 자료를 이용한 지표면 피복 조건의 차이가 대구의 도시 열환경에 미치는 영향 (Effect of Difference of Land Cover Conditions on Urban Thermal Environment in Daegu Using Satellite and AWS Data)

  • 안지숙;김해동;김상우
    • 한국환경과학회지
    • /
    • 제19권3호
    • /
    • pp.281-293
    • /
    • 2010
  • The present study explores time and spatial thermal environment for Daegu, which is a city built on a basin area, according to varying land cover conditions of the earth's surface by analyzing data derived from meteorological observation and satellite images. The study has classified land use by utilizing MODIS satellite images and analyzed land surface temperature. Also, by using data acquired from automatic weather system, the study has evaluated the effects of atmospheric heating caused by city pavements by analyzing the sensible heat flux between the city's land surface and the atmosphere. The results are as follows. 1) Classification of land use in the Daegu area shows 46.64% of urban and built-up area, 1.39% of watersides, 35.19% of forest, 11.43% of crops, and 5.37% grasslands. 2) During the weekdays throughout the year, the land surface temperature was high for Dalseogu, Bukgu, and Seogu regions where industrial complexes could be found. Comparatively, lower temperature could be observed in the woodlands. 3) While the land surface temperature displayed the effects of pushing air upwards during the weekdays in urban areas, the reverse was true for forest regions. During the night, the temperature did not exert any significant influence on air movement.

Current status and prospects for in-feed antibiotics in the different stages of pork production - A review

  • Li, Junyou
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제30권12호
    • /
    • pp.1667-1673
    • /
    • 2017
  • Antibiotics have long been of great benefit for people, both in the medical treatment of human disease and in animal food where they improve the growth performance and feed utilization during animal production. Antibiotics as in-feed supplements affect all stages of pork production, including the gestation, nursing, growing, and finishing stages, although the effects show stage-dependent differences. However, the use of antibiotics in animal feed has become a worldwide concern. This review describes why sub-therapeutic levels of antibiotic additives in animal feed have become an integral part of animal feeding programs for more than 70 years, particularly in pork production. It also discusses the threat of the long-term use of sub-therapeutic levels of antibiotics in pork production. In recent years, the effectiveness of in-feed antibiotics has tended to decrease. This review analyzes this change from various perspectives. First, the equipment used at pig farms has improved dramatically and is more sanitary. Worldwide, more pig farms use pig farrowing crates, gestation crates, piglet nursery crates, flooring devices, piggery ventilation and cooler systems, automatic pig feeders, piggery heating equipment, and artificial insemination systems. In addition, scientists have replaced the use of antibiotics with organic acids, fermented mash, probiotics, prebiotics, minerals, oligosaccharides, enzymes, herbs/flavors, and protein/amino acids, and have improved management and husbandry techniques. In addition, animal welfare legislation has been aimed at improving the quality of the floors and living space, ensuring that animals have permanent access to fresh water, and setting a minimum weaning age. Finally, the prospects and the possibility of replacing antibiotics in pork production are described, in line with recent research results.

시설원예용 태양열 시스템의 효율적 이용과 자동화 장치개발(1) - 시설재배시 지중가온의 온도변화 연구 - (A Development of Automation System and a Way to use Solar Energy System Efficiently in Greenhouse(1) - Study on temperature variation of soil heating in greenhouse -)

  • 김진현;김철수;명병수;최중섭;구건효;김태욱
    • 생물환경조절학회지
    • /
    • 제7권1호
    • /
    • pp.15-24
    • /
    • 1998
  • 태양열 에너지의 효율적인 이용과 자동화 장치의 개발을 목표로 지중가온의 온도변화 특성을 실험. 분석한 결과는 다음과 같다. 1) 10월 13일의 1일 하우스 내기온이 주야간에 24$^{\circ}C$의 차이가 있으며, 무가온시 지온변화는 지중 10 m 부근에서 6$^{\circ}C$, 지중 20 cm 부근에서는 3$^{\circ}C$정도의 차이를 보이고 있다. 2) 20시경에 내기온과 지온차가 가장 작은 것으로 나타났으며, 지중 20 cm 부근의 온도변화는 내기온이 가장 낮은 오전 7시부터 약 3시간이 경과된 오전 10시에 최저가 되었다 3) 가온수의 온도를 4$0^{\circ}C$, 5$0^{\circ}C$, 6$0^{\circ}C$로 변화하였을 때 지중 10 cm의 최저은도는 약 2$0^{\circ}C$ 지중 20 cm의 최저온도는 약 23$^{\circ}C$로 나타나 가온온도가 4$0^{\circ}C$ 이상일 경우 가온온도에 따른 지중 10~20 cm사이의 온도차는 매우 작았다. 4) 지중 15~20 cm의 지온이 2$0^{\circ}C$가 되기 위해서는 가온수의 온도를 4$0^{\circ}C$ 이하가 되도록 설정하여야한다. 5) 가온수의 온도가 4$0^{\circ}C$, 5$0^{\circ}C$, 6$0^{\circ}C$이고 파이프 매설 깊이가 12 m일 경우 유입구와 유출구의 1일 평균온도차는 4$0^{\circ}C$일 경우 3.5$^{\circ}C$ 5$0^{\circ}C$일 경우 4.4$^{\circ}C$, 6$0^{\circ}C$일 경우 5.4$^{\circ}C$정도로 이 구간에서 온도변화식은 T = 0.09591T+2.5451($R^2$= 0.9966)로 거의 선형적으로 변화하였다. 6) 가온수 온도가 4$0^{\circ}C$의 경우 지중 15~20 cm, 5$0^{\circ}C$의 경우는 지중 13~19 cm, 6$0^{\circ}C$의 경우는 12~17 cm 부근이 경계영역으로 판단되었다. 7) 재배기간중 하우스 내기온을 11$^{\circ}C$ 이상으로 유지하고, 가온수의 온도를 28$^{\circ}C$로 순환 결과 지중 15 cm 이하에서 최저지온를 2$0^{\circ}C$ 이상의 온도를 유지할 수 있어 저온수공급에 의한 온도상승효과가 뚜렷이 나타났다. 8) 가온수의 온도를 28$^{\circ}C$로 하여 지중가온 한 결과 지중 15~20 cm사이에 온도변화는 무가온구에 비하여 공히 4$^{\circ}C$~7$^{\circ}C$가 상승되었다.

  • PDF

설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008)

  • 한화택;최창호;이대영;김서영;권용일;최종민
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.