• 제목/요약/키워드: Automatic Water Quality Monitoring

검색결과 52건 처리시간 0.024초

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

하수처리장 유입수의 특성평가를 위한 실시간 수질예측 (Real-time Water Quality Prediction for Evaluation of Influent Characteristics in a Full-scale Sewerage Treatment Plant)

  • 김연권;채수권;한인선;김주환
    • 환경영향평가
    • /
    • 제19권6호
    • /
    • pp.617-623
    • /
    • 2010
  • It is the most important subject to figure out characteristics of the wastewater inflows of sewerage treatment plant(STP) when situation models are applied to operation of the biological processes and in the automatic control based on ICA(Instrument, Control and Automation). For the purposes, real-time influent monitoring method has been applied by using on-line monitoring equipments for the process optimization in conventional STP. Since, the influent of STP is consist of complex components such as, COD, BOD, TN, $NH_4$-N, $NO_3$-N, TP and $PO_4$-P. MRA2(Microbial Respiration Analyzer 2), which is capable of real-time analyzing of wastewater characteristics is used to overcome the limitations and defects of conventional online monitoring equipments in this study. Rapidity, accuracy and stability of developed MRA2 are evaluated and compared with the results from on-line monitoring equipments for seven months after installation in Full-scale STP.

국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰 (Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading)

  • 주진철;안호상;안창혁;고경록;오현제
    • 대한환경공학회지
    • /
    • 제34권12호
    • /
    • pp.863-870
    • /
    • 2012
  • 본 연구에서는 디지털 수도계량기(smart water meter) 연계형 상수도 원격검침시스템(automatic meter reading)의 국외 시장동향 및 원격검침시스템의 각 구성 요소기술의 개발현황과 현장적용 사례 등을 조사 분석하였다. 국외의 디지털 수도계량기 제조업체는 주로 미국 또는 유럽업체들로서 최근에는 북미뿐만 아니라 아시아 및 유럽에서도 원격검침시스템 사업을 확장하고 있다. 대부분의 디지털 수도계량기 제조업체는 원격검침용 디지털 수도 계량기에서 측정된 데이터를 활용하여 실시간 소비량 검침 및 비용 고지, 절수, 누수탐지, 수질 모니터링, 유량제어 등의 기능이 부가된 통합관리시스템(integrated water management system)과 연계하여 운영하고 있다. 데이터 전송방식은 디지털 수도계량기, 센서를 통해 검출된 데이터를 근거리 통신망(neighborhood area network)을 통해 수집기(data concentration unit)로 전송 후 광역 통신망(wide area network)을 통해 검침서버로 전송하였으며, 데이터 전송방식은 도시 규모, 계량기의 밀도, 전력공급 여부 및 통신망의 설치 여부 등을 종합적으로 고려하여 결정되었다. 일반적인 검침방식은 (1) 고정망(fixed network)을 통한 중앙 검침, (2) 차량(drive by)을 이용한 검침, (3) 사람(walk by)에 의한 검침, 그리고 (4) 비행식(fly by) 검침방식 등이 적용되었다. 전 세계적으로 디지털 수도계량기 연계형 원격검침시스템이 확산되어 용수 및 에너지를 절감하고 수도 요금을 절약하여 온실가스의 배출을 최소화하고 있는 것으로 판단된다.

낙동강 남강 합류부 수위와 수질 패턴 및 추세 (Patterns and Trends of Water Level and Water Quality at the Namgang Junction in the Nakdong River Based on Hourly Measurement Time Series Data)

  • 양득석;임태효;이인정;정강영;김경훈;권헌각;유제철;안정민
    • 한국환경과학회지
    • /
    • 제27권2호
    • /
    • pp.63-74
    • /
    • 2018
  • As part of the Four Major Rivers Restoration Project, multifunctional weirs have been constructed in the rivers and operated for river-level management. As the weirs play a role in draining water from tributaries, the aim of this study was to determine the influence of the weirs on the water level of the Nam River, which is one of the Nakdong River's tributaries. Self-organizing maps (SOMs) and a locally weighted scatterplot smoothing (LOWESS) technique were applied to analyze the patterns and trends of water level and quality of the Nakdong River, considering the operation of the Changnyeong-Haman weir, which is located where the Nam River flows into the Nakdong River. The software program HEC-RAS was used to find the boundary points where the water is well drained. Per the study results at the monitoring points ranging between the junction of the two rivers and 17.5 km upstream toward the Nam River, the multifunctional weir influenced the water level at the Geoyrong and Daesan observation stations on the Nam River and the water quality based on automatic monitoring at the Chilseo station on the Nakdong River was affected strongly by the Nakdong River and partly by the Nam River.

수질샘플빈도에 따른 산림유역의 비점원오염부하특성 (Characteristics of Nonpoint Source Pollutant Loads from Forest watershed with Various Water Quality Sampling Frequencies)

  • 신민환;신용철;허성구;임경재;최중대
    • 한국농공학회논문집
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2008
  • A monsoon season monitoring data from June to September, 2005 of a small forested watershed located at the upstream of the North Han River system in Korea was conducted to analyze the flow variations, the NPS pollutant concentrations, and the pollution load characteristics with respect to sampling frequencies. During the 4-month period, 1,423 mm or 79.2% of annual rainfall(1,797 mm) were occurred and more than 77%, 54% and 68% of annual T-N, $NO_3$-N and T-P loads discharged. Flow rate was continuously measured with automatic velocity and water level meters and 58 water quality samples were taken and analyzed. It was analyzed that the flow volume by random measurement varied very widely and ranged from 79% to 218% of that of continuous measurement. It was recommended that flow measurement of small forested watersheds should be continuously measured with automated flow meters to precisely measure flow rates. Flow-weighted mean concentrations of T-N, $NO_3$-N and T-P during the period were 2.114 mg/L, 0.836 mg/L, and 0.136 mg/L, respectively. T-N, $NO_3$-N and T-P loads were sensitive to the number of samples. And it was analyzed that in order to measure the pollution load within the error of 10% to the true load, the rate of sampling frequency should be higher than 89.7% of the sample numbers that were required to compute the true pollution load. If it is compared to selected foreign research results, about 10 water samples for each rainfall event were needed to compute the pollution load within 10% error. It is unlikely in Korea and recommended that thorough NPS pollution monitoring studies are required to develop the standard monitoring procedures for reliable NPS pollution quantification.

냉각탑 수질관리를 위한 자동화 시스템 개발 (Water Quality Control System Development for Cooling Towers)

  • 이기건;송무준;이영재;성상경;강태삼
    • 제어로봇시스템학회논문지
    • /
    • 제14권1호
    • /
    • pp.36-41
    • /
    • 2008
  • Cooling tower is an important equipment of the cooling systems for large buildings like factory and department store. Water used for cooling in cooling tower is reused continuously. If the water is polluted, corrosion and scale can happen at equipments and pipes. In order to prevent this problem, it is necessary to control the water quality using chemicals. To control the water quality, an automatic control system is designed, fabricated, and experimented. The control system is based on an imbedded microcontroller. Relays are used for power driving, an LCD and LED for display, and RS485 for remote data acquisition. Monitoring program is also developed for easy man-machine interface and extraction of data stored in the imbedded processor and EEPROM. The control system calculates amounts of chemicals necessary using sensor data and injects the chemicals into the cooling tower on proper time. The developed water quality control system is expected to reduce cost of maintenance and extend the lifetime of the cooling systems with low cost.

한강수질 평가를 위한 COD (화학적 산소 요구량) 모델 평가 (Chemical Oxygen Demand (COD) Model for the Assessment of Water Quality in the Han River, Korea)

  • Kim, Jae Hyoun;Jo, Jinnam
    • 한국환경보건학회지
    • /
    • 제42권4호
    • /
    • pp.280-292
    • /
    • 2016
  • Objectives: The objective of this study was to build COD regression models for the Han River and evaluate water quality. Methods: Water quality data sets for the dry season (as of January) during a four-year period (2012-2015) were collected from the database of the Han River automatic water quality monitoring stations. Statistical techniques, including combined genetic algorithm-multiple linear regression (GA-MLR) were used to build five-descriptor COD models. Multivariate statistical techniques such as principal component analysis (PCA) and cluster analysis (CA) are useful tools for extracting meaningful information. Results: The $r^2$ of the best COD models provided significant high values (> 0.8) between 2012 and 2015. Total organic carbon (TOC) was a surrogate indicator for COD (as COD/TOC) with high reliability ($r^2=0.63$ in 2012, $r^2=0.75$ for 2013, $r^2=0.79$ for 2014 and $r^2=0.85$ for 2015). The ratios of COD/TOC were calculated as 2.08 in 2012, 1.79 in 2013, 1.52 and 1.45 in 2015, indicating that biodegradability in the water body of the Han River was being sustained, thereby further improving water quality. The BOD/COD ratio supported these findings. The cluster analysis revealed higher annual levels of microorganisms and phosphorous at stations along the Hangang-Seoul and Hantangang areas. Nevertheless, the overall water quality over the last four years showed an observable trend toward continuous improvement. These findings also suggest that non-point pollution control strategies should consider the influence of upstreams and downstreams to protect water quality in the Han River. Conclusion: This data analysis procedure provided an efficient and comprehensive tool to interpret complex water quality data matrices. Results from a trend analysis provided much important information about sources and parameters for Han River water quality management.

환경 모니터링을 위한 무인 호버크래프트 시스템 개발 (Development of unmanned hovercraft system for environmental monitoring)

  • 유성구;임진택
    • 문화기술의 융합
    • /
    • 제10권2호
    • /
    • pp.525-530
    • /
    • 2024
  • 환경정보를 실시간으로 획득하여 정보를 제공하는 환경 모니터링 시스템 필요성이 확대되고 있다. 특히 공공수역 수질관리의 경우 법적으로 수동측정과 자동측정을 통해 상시 관리를 진행해야 하며, 대기오염도 탄소중립 실현과 연관하여 미세먼지, 배기가스 저감을 위한 상시 측정 및 관리가 필요한 실정이다. 본 연구에서는 수질오염 및 대기오염 정보를 실시간으로 측정하여 모니터링을 할 수 있는 시스템을 구현하였다. 측정을 위한 도구로 육상과 수상을 동시에 이동 가능한 호버크래프트를 활용하였다. 호버크래프트 본체에 수질측정 및 대기오염측정 센서를 장착하고 그 정보를 실시간으로 모니터링 시스템으로 전송할 수 있는 통신 모듈을 장착하였다. 환경측정용 호버크래프트의 구조를 설계하였으며, 실시간 정보전달 통신 모듈로는 저전력 장거리 통신이 가능한 LoRa 모듈을 적용하였다. 실제 하드웨어 구현을 통해 제안한 시스템의 동작 성능을 확인하였다.

주차장 및 교량지역의 강우유출수내 비점오염물질의 특성 비교 및 동적 EMCs (Characteristics of Washed-off Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms)

  • 김이형;이선하
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.248-255
    • /
    • 2005
  • Since the water quality of drinking water sources has been recognized as a big issue, the ministry of Environment in Korea is designing the total maximum daily load (TMDL) program for 4 major large rivers. The TMDL program can be successfully performed as controling the nonpoint pollutants from watershed area near the river. Of the various landuses in nonpoint pollution, parking lots and bridges are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicular activities. Vehicle emissions from those areas include different pollutants such as heavy metals, oil and grease and particulates from sources such as fuels, brake pad and tire wear, etc. Especially the pollutant washed-off from the landuses are directly affecting to the river water quality. Therefore this research was conducted to understand the magnitude and nature of the stormwater emissions with the goal of quantifying stormwater pollutant concentrations and mass emission rates of pollutants from parking lot and bridges in Korea. In Kongju city areas, two monitoring sites were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the useful data such as rainfall, water quality and runoff flow. This manuscripts will show the concentration changes during storm duration and EMCs to characterize the concentration profiles in different land uses. Also the first flush criteria will be suggested using dynamic EMCs. The definition of dynamic EMC is a new approach explaining the relationship of EMC and first flush effect.

원격 자동 수질 측정 기록 시스템 연구 (A Study on Remote automatic water quality measurement recording systems)

  • 손오섭;장종욱
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.447-450
    • /
    • 2010
  • 오늘날 상대적으로 미비한 소규모저수지 및 간척담수호 농업용수의 수질정보를 온라인으로 수집 및 분석하고, 분석된 정보를 실시간으로 전달 및 데이터베이스화함으로써 농업용저수지와 담수호의 수질관리를 체계적으로 할 수 있다. 본 논문에서는 원격에서 자동으로 수질을 측정하고 사용자에게 측정된 정보를 제공하기 위해 각 센서로부터 수집된 정보를 통합 처리 이후 무선 네트워크를 통해서 실시간으로 통합관리 함으로써 관측지점에 대한 수질정보를 실시간으로 모니터링 할 수 있으며 이동 통신망의 이용도 가능한 시스템을 제안하고자 한다.

  • PDF