Validating Timing of Vehicle Automatic Shut-off and Study on Appropriate Shut-off Timing (자동 Shut-off 시간 적정성 검증 방법 및 최적 시간 설정 방안 연구)

  • Yang, Dong Il;Choi, Byeong Nam;Park, Ji Woon;Yu, Min Sang;Beema, Stephanie
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.2
    • /
    • pp.15-23
    • /
    • 2021
  • Even though the number of CO poisoning casualties caused by unintended idling for the vehicles equipped with keyless ignition systems is more than 70, the problem still remains unsolved and became social issue in the US, and Senates introduced the bill which urges NHSTA to make regulation for this accordingly. To meet market safety needs and the regulations, we decided to provide automatic shut-off system very soon. In this paper, we would like to describe how to validate vehicle shut-off timing including defining required tests and case selections considering vehicle condition, garage/room size and temperatures with several assumptions. We believe that safe implementation of the shut-off function is possible via this methodology and the results. As NHTSA must be interested in shut-off timing, the methodology can be enhanced and conclusions could be reflected highly in the future regulation in case we continue this study with NHTSA or any other 3-rd party institutes.

Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder (LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.80-84
    • /
    • 2015
  • In this paper, the valves for a LPG gas cylinder have been investigated on the body height and weight by comparing design data between typical automatic shut-off vertical and newly developed horizontal valves. The height of an automatic shut-off horizontal valve is radically reduced by 41~42% compared with that of a typical automatic shut-off vertical valve. And, the body weight of a horizontal valve is also reduced by 29~40% compared with that of a vertical shut-off valve. This result is just achieved by a structural design modification from typical vertical valve to horizontal arrangement of various valve components.

Study on Divice for the Automatic Shut Off of Equipment Stand-by Power (자동전원 계폐장치에 관한 연구)

  • Kim, H.K.;Hyun, K.W.;Bae, J.I.;Yang, S.Y.;Park, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2626-2627
    • /
    • 1999
  • The device we have developed is the automatic shut off equipment which will reduce energy consumption when an equipment is in stand by power state. The principle for this system is when a man is moving, electricity will flow by setting a on-off light system. At night, in the stand-by power state the electric supply will be shut off immediately which will reduce energy consumption. Energy consumed by 24hour operating machines and stand-by electronic devices will be reduced by pulse signals which will give power supply when needed.

  • PDF

A Study on the Internal Flow Analysis of High-pressure Shut-off Valve for CNG Charging Station Piping System (CNG 충전소 배관시스템용 고압 차단밸브에 대한 내부 유동해석에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.773-779
    • /
    • 2021
  • CNG, which has recently been attracting attention as an alternative fuel in the transportation field to reduce emissions caused by global warming, is natural gas with abundant reserves and mainly composed of methane. Being in a gaseous state, natural gas requires the compression and liquefaction processes for transportation. Until now, general shut-off valves for liquid and gas piping have been developed in Korea, but there are few studies on shut-off valves for high pressures of about 200 bar. Currently, research on the flow analysis of valves is being actively conducted around the world. However, there are relatively many studies on large valves such as low-pressure valves or shipbuilding and marine, and the safety factor through structural analysis to check the structural integrity of the valve is checked at the design stage. Since it is necessary to have a fast response speed while minimizing pressure and speed loss due to flow change, basic research was conducted on the flow analysis of the valve to secure design data, and the numerical analysis was performed on high-pressure automatic shut-off valves applied to CNG refueling stations. After securing the basic valve shape through reverse engineering for advanced products, we compared the valve flow coefficient Cv coefficient with advanced products. As a result, it was found that the reverse engineering model was at the level of about 60%. However, we compared the Cv coefficient by modifying the reverse engineering model, and the result showed that it was improved to about 96%.

Experiment Study on Operation Model of Automatic Cylinder Valve by the Temperature Differences (온도차 변동에 따른 전자밸브 작동모델 실험적 연구)

  • Jang, Kap-Man;Eom, Seok Hwa;Kim, In Chan;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.73-79
    • /
    • 2012
  • Currently, all domestic CNG vehicles have manual cylinder valves installed. These are inconvenient for drivers in case of a gas leak accident, because drivers have to stop the vehicle operation and manually close the valve. It makes difficult condition for drivers to quickly and properly respond to such accidents. In advanced European countries, they require Automatic cylinder valve installation, which has a structure where the valve is automatically shut off when the driver turns off the ignition in case of a gas leak. If this electric valve system is introduced in Korea, the safety of CNG buses will be improved with better functionalities. In this paper, in order to solve the structural problem of difficulty for a driver to identify the operational status of individual Automatic cylinder valves, an approach was made regarding temperature increase with pressure increase during CNG filling. it was estimated that the temperature increased approximately more than $30^{\circ}C$ due to pressure difference during the filling. Therefore, it was concluded from the experimental data that the valve of the container whose temperature did not increase did not operate, resulting in filling failure.

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor (화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구)

  • Byun, Yoon Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.32-38
    • /
    • 2020
  • Based on the cases of fire and explosion accident in the chemical reactor, thr problems of preventive measures installed in the chemical reactor were analyzed. The chemical reactors produce a variety of chemicals and install rupture disk to relieve the pressure that rises sharply in the event of a runaway reaction. In order to maintain the function of the rupture disk, the emissions was allowed to be discharged into the atmosphere, resulting in fire and explosion accidents. As a way to improve this, safety instrumented system based on the safety integrity level(SIL3) was applied as a preventive measures for chemical reactor. Two emergency shur-off valves are installed in series on pipe dropping raw materials for chemical reactor so that the supply of raw materials can be cut off even if only one of the two emergency shut-off valves is operated during the runaway reaction. The automatic on/off valve is installed in parallel in the supply pipe of the reaction inhibitor so that the reaction inhibitor can be injected even if only one valve is opened at the time of the runaway reaction.

Reply-Type based Agent Generation of Legacy Service on One-way data transfer system (일방향 자료전달 시스템의 레거시 서비스 지원을 위한 응답구조 기반 에이전트 자동 생성)

  • Kim, Kyoung-Ho;Chang, Yeop;Kim, Hee-Min;Yun, Jeong-Han;Kim, Woo-Nyon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.2
    • /
    • pp.299-305
    • /
    • 2013
  • Physical One-way Transfer, one of network Separating Network Technologies, shut off intrusion possibilities by removing data transfer line from external network to internal network. Physical One-way Transfer technology can not support legacy services based duplex transmission. Legacy services operating need agent for extra service with the support. But, Agent development have problems with adding cost and open internal protocols. In this papers, We analyzed legacy services between Control network and OA network in working SCADA systems, and based on the results obtained from the analysis, categorized the legacy services into three forms. We propose an agent generation method of the three service categories for Physical One-Way Transfer System. In addition, we design an automatic generation tool using the proposed method.