• Title/Summary/Keyword: Automatic Reading

Search Result 165, Processing Time 0.022 seconds

Automatic Reading System for On-off Type DNA Chip

  • Ryu, Mun-Ho;Kim, Jong-Dae;Kim, Jong-Won
    • Journal of Information Processing Systems
    • /
    • v.2 no.3 s.4
    • /
    • pp.189-193
    • /
    • 2006
  • In this study we propose an automatic reading system for diagnostic DNA chips. We define a general specification for an automatic reading system and propose a possible implementation method. The proposed system performs the whole reading process automatically without any user intervention, covering image acquisition, image analysis, and report generation. We applied the system for the automatic report generation of a commercialized DNA chip for cervical cancer detection. The fluorescence image of the hybridization result was acquired with a $GenePix^{TM}$ scanner using its library running in HTML pages. The processing of the acquired image and the report generation were executed by a component object module programmed with Microsoft Visual C++ 6.0. To generate the report document, we made an HWP 2002 document template with marker strings that were supposed to be searched and replaced with the corresponding information such as patient information and diagnosis results. The proposed system generates the report document by reading the template and changing the marker strings with the resultant contents. The system is expected to facilitate the usage of a diagnostic DNA chip for mass screening by the automation of a conventional manual reading process, shortening its processing time, and quantifying the reading criteria.

Automatic Meter Reading System for Water-Supply (상수도 자동 검침 시스템 구축에 관한 연구 : 부산 기장군과 김해시 사례를 중심으로)

  • Seo, Chang-Gab;Park, Young-Jae
    • Journal of Digital Convergence
    • /
    • v.7 no.3
    • /
    • pp.103-111
    • /
    • 2009
  • In this paper, we introduce automatic meter reading system for tap water. The system is composed of automatic meter, router using RF and CDMA network, and data server. This system will easily extend to fire detect, gas, and electric charge meter system. In addition, this system will be used to monitoring a water leak and human which live in solitude. Proposed system is installed at Gimhae-City and Gijang-gun. As a result of the automatic meter reading system for tap water, The leak of water and complain of user is decreased. But The building cost is still an obstacle to expand into entire city.

  • PDF

Design of Automatic Meter Reading using RF transceiver module (RF 트랜시버 모듈을 이용한 자동원격검침 시스템의 설계)

  • Jeong Won-Chang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.4 s.32
    • /
    • pp.179-184
    • /
    • 2004
  • Meter reading system, operated by meter staff who reads the meter and record consumption with handhold data terminals. can cause privacy intrusion, unread meter data, abnormal readings and excessive expenses of maintaining the system. To prevent the deterioration of customer service quality, Automatic Meter Reading system, which automatically recognizes meter readings and transmit reading data through wireless RF module, is designed. From collecting the reading data to managing statistics of customer's consumption information. this automatic meter reading system provides more accurate and fast information to customers. By designing this system, customer service satisfaction and reliability can be improve

  • PDF

Implementation of Wireless AMR System using Binary CDMA (Binary CDMA 기술을 이용한 무선 원격검침 시스템 구현)

  • Kwon, Tai-Gil;Cho, Jin-Woong;Hong, Dae-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • This paper presents the AMR (Automatic Meter Reading) system using the binary CDMA (Code Division Multiple Access) radio technology. The binary CDMA is the new radio technology in domestic research. Main implementation topics includes the binary CDMA remote meter reading system, the wireless piconet configuration for the wireless automatic meter reading, and the transmission scheduling for sending and receiving data. Also, the wireless packet data encryption is very important topics for the wireless automatic meter reading. The proposed AMR system is implemented as a pilot project in Jeju and Gangwon. It can be seen that the wireless remote reading using the binary CDMA wireless technology can be applied to the AMR system.

Development of Automatic Reading System for Steam Sterilization Indicator (스팀 멸균지시제 자동판독시스템 개발)

  • Song, Hyeok;Kim, Jeong-Rae;Lee, Woo-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.709-714
    • /
    • 2022
  • The color change of the success of the steam sterilization indicator used in steam sterilization is currently being read by relying on the human eye. The result of color change on the success of sterilization can only be accurately read and judged by trained personnel. Developed an automatic reading system for steam sterilization indicators for the current human-dependent system, and developed an automatic reading device system for reading methods that were previously relied on with the human eye to develop a system that is more accurate and easier for anyone to read.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

Efficient Allocation and Connection of Concentrators and Repeaters Using Approximate Steiner Minimum Tree in Automatic Meter Reading System (원격 검침 시스템에서 근사 최소 스타이너 트리를 이용한 집중기 및 중계기의 효율적인 배치와 연결)

  • Kim, Chae-Kak;Kim, In-Bum;Kim, Soo-In
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.994-1003
    • /
    • 2009
  • For Automatic Meter Reading System, good topology of check machines, concentrators, and repeaters in client field is important. Steiner Minimum Tree is a minimum cost tree connecting all given nodes with introducing Steiner points. In this paper, an efficient mechanism allocating and connecting check machines, concentrators and repeaters which are essential elements in automatic meter reading system is proposed, which conducts repeated applications of building approximate Minimum Steiner Trees. In the mechanism, input nodes and Steiner points might correspond to check machine, concentrators or repeaters and edges might do to the connections between them. Therefore, through suitable conversions and processes of them, an efficient network for automatic meter reading system with both wired and wireless communication techniques could be constructed. In our experiment, for 1000 input nodes and 200 max connections per node, the proposed mechanism shortened the length of produced network by 19.1% comparing with the length of Minimum Spanning Tree built by Prim's algorithm.

Develpoment of Automatic Meter Reading Program for Electronic Power Meter (전자식 전력량계용 한전 프로토콜 및 운영 프로그램 개발)

  • Yu, In-H.;Jang, Mun-J.;Hyun, Duk-H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2219-2221
    • /
    • 2001
  • A communication protocol for automatic meter reading is designed for electronic power meter. Communicational functions and data structures are standardized and data reading software is developed according to the developed protocol. The communication protocol is designed with reference specifications, IEC 62056-31 and Distributed Network Protocol(DNP). For design, communicational functions and specifications of the industrial meters were analyzed for the purpose of developing a new one for KEPCO meters. The protocol is designed with 3 layer model, physical layers, data link layer and application layer. A documentation was completed with data gathering, data classification, authentication, error detection. An emulator system was made for testing the protocol. A meter reading software was developed using the protocol. Many different protocols and meter reading softwares are integrated into one with the developed protocol and software as KEPCO's standard.

  • PDF

Development of PC Controled Automatic Cutting System (PC를 이용한 철판 자동절단시스템 개발)

  • Kim, Sang-Hun;Chung, Kyung-Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.1
    • /
    • pp.29-37
    • /
    • 1996
  • In this study, PC controlled CNC automatic cutting system is developed. Technological introduction of the control process and the computer programming has made possible not only the automatic control for cutting processing unit but also the easy-to-use graphic software that enables the cutting process. This program involves shape part drawing and amendment, pattern reading and saving, reading Autocad file, nesting process, kerf compensation, automatic cutting path generation, NC file conversion and motor control. Software is devided into 3 modules for easy work. First step enables drawing, amendment and pattern making, followed by automatic nesting and cutting path generation with kerf compensation. In the final step, drawing data is transmitted for the resulting automatic cutting processes. This software would be applicated in gas cutting and textile cutting so that it improves the productivity of cutting process.

  • PDF

Typical Daily Load Profile Generation using Load Profile of Automatic Meter Reading Customer (자동검침 고객의 부하패턴을 이용한 일일 대표 부하패턴 생성)

  • Kim, Young-Il;Shin, Jin-Ho;Yi, Bong-Jae;Yang, Il-Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1516-1521
    • /
    • 2008
  • Recently, distribution load analysis using AMR (Automatic Meter Reading) data is researched in electric utilities. Load analysis method based on AMR system generates the typical load profile using load data of AMR customers, estimates the load profile of non-AMR customers, and analyzes the peak load and load profile of the distribution circuits and sectors per every 15 minutes/hour/day/week/month. Typical load profile is generated by the algorithm calculating the average amount of power consumption of each groups having similar load patterns. Traditional customer clustering mechanism uses only contract type code as a key. This mechanism has low accuracy because many customers having same contract code have different load patterns. In this research, We propose a customer clustring mechanism using k-means algorithm with contract type code and AMR data.