• Title/Summary/Keyword: Automatic Fire Extinguishing System

Search Result 32, Processing Time 0.025 seconds

Design and Implementation of the Automatic Fire Extinguishing System Based on the Ignition Point Tracking using the Flame Detecter (화재감지기를 사용한 발화점추적기반의 자동소방시스템 설계 및 구현)

  • Paik, Seung Hyun;Kim, Young Wung;Oh, Se Il;Park, Hong Bae
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.155-161
    • /
    • 2013
  • To reduce the personnel and material loss caused by fire, we propose the automatic fire extinguishing system based on the ignition point tracking using the flame detecter. This automatic fire extinguishing system is composed of the flame detecting system and the fire extinguishing system based on the water cannon. We study the method for the ignition point tracking and the automatic fire extinguishing using the water cannon and the flame detecter. The flame detecting system for the early fire detection and the ignition point tracking has to be satisfied the requirement of the detecting range and the flame detection time. So we study the signal process algorithm for an improvement of the flame detecting system.

Implementation of Automatic Extinguishing System for fire suppression of vehicle (차량 화재 진압을 위한 자동 소화 시스템 구현)

  • Ryu, Hye-Yeon;Kim, Man-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.227-233
    • /
    • 2019
  • In recent years, vehicle fires account for the second highest rate after residential fires. It accounts for more than 10.7% of the total fire occurrence rate. Vehicle fires are very difficult to evolve at an early stage. Most of the vehicles are burned down in the event of a fire, resulting in a lot of physical and personal damage. In the EU and other countries, efforts are being made to install automatic fire extinguishing systems in preparation for vehicle fires. In addition, since the automatic fire extinguishing system applied to a vehicle must operate in a moving state of a car, a method for detecting a fire is needed. Therefore, this paper proposes a structure of an automatic fire extinguishing system that can evolve a fire when a fire occurs in a commercial vehicle among various vehicles. Especially, it confirms the feasibility of the automatic fire extinguishing system simulated in the laboratory environment and confirms its applicability.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles (자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구)

  • Lim, Sung-Muk;Jung, Ki-Chang;Kim, Hong;Kang, Young-Goo;Lee, Chang-Sub
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

Developing of an extinguishing system for a fire at an early stage in Unmanned Engine Room for small vessels (소형선박용 무인기관실 초기화재 진압시스템 개발)

  • Kim, Sung-Yoon;Kim, Dong-Seuk;Kim, You-Taek
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.333-334
    • /
    • 2006
  • Extinguishing a fire at an early stage is most important to prevent spreading of a fire in Unmanned Engine Room. The most proper fire extinguish system was analyzed after examining the Automatic spread Extinguish System, which is mostly installed in Unmanned Engine Room, reproduced in the condition of real Unmanned Engine Room.

  • PDF

A Study on the Development of Fire Extinguishing System for Machinery Spaces of a Small craft (무인기관실에 효과적인 자동소화장치개발 관한 연구)

  • Lee, Chan-Jea;Kang, Dae-Sun;Kim, Dong-Suk;Kwark, Ji-Hyun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.127-128
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, $8m^3$ respectively. The openings and fans were established on the walls of the compartments. Diesel oil was used for the test fuel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

A study on practical use of remote automatic fire extinguishing equipment through test bed in road tunnel (도로터널용 원격 자동소화 설비의 test bed 적용을 통한 실용화 방안 연구)

  • Park, Sang-Heon;An, Sung-Joo;Kim, Jae-Hoon;Kim, Kyung-soo;Yun, Jun-Su;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.837-847
    • /
    • 2019
  • Korea's long underground roads are being promoted around the metropolitan city center to realize advanced transportation networks. Many disaster prevention facilities are applied to secure fire safety of the closed and long-distance underground roads. As the facility response and fire suppression subjects are unclear, additional human and material damages from fire spread are inevitable. Therefore, in this study, we developed a remote automatic fire extinguishing system that uses the fire extinguishing water inside the fire hydrant to monitor the CCTV in the management room and sprays it directly to the fire site through automatic control. The design application method was studied through the performance improvement that can be put into practical use.

An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space (밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구)

  • Jeon, Kil Song;Hwang, Ji Hyun;Lee, Tea Won
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.