• Title/Summary/Keyword: Automated X-ray

Search Result 47, Processing Time 0.026 seconds

The study of the stereo X-ray system for automated X-ray inspection system using 3D-reconstruction shape information (3차원 형상복원 정보 기반의 검색 자동화를 위한 스테레오 X-선 검색장치에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2043-2050
    • /
    • 2014
  • As most the scanning systems developed until now provide radiation scan plane images of the inspected objects, there has been a limitation in judging exactly the shape of the objects inside a logistics container exactly with only 2-D radiation image information. As a radiation image is just the density information of the scanned object, the direct application of general stereo image processing techniques is inefficient. So we propose that a new volume-based 3-D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for X-ray inspection. For validation of the proposed shape reconstruction algorithm using volume, 15 samples were scanned and reconstructed to restore the shape using an X-ray stereo inspection system. Reconstruction results of the objects show a high degree of accuracy compared to the width (2.56%), height (6.15%) and depth (7.12%) of the measured value for a real object respectively. In addition, using a K-Mean clustering algorithm a detection efficiency of 97% is achieved. The results of the reconstructed shape information using the volume based shape reconstruction algorithm provide the depth information of the inspected object with stereo X-ray inspection. Depth information used as an identifier for an automated search is possible and additional studies will proceed to retrieve an X-ray inspection system that can greatly improve the efficiency of an inspection.

Automated Detection of Pulmonary Nodules in Chest X-ray Radiography Using Genetic Algorithm (흉부 X-ray 영상에서 유전자 알고리즘을 이용한 폐 결절 자동 추출)

  • 류지연;이경일;장정란;오명진;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.553-555
    • /
    • 2002
  • 컴퓨터지원진단(Computer Aided Diagnosis; CAD) 시스템은 방사선 의사들이 흉부 X-ray 영상에서 결절을 탐지하는데 있어 실제적으로 발생할 수 있는 오진율을 줄이고, 폐 결절이 존재하는 폐야에서 결절의 존재 유무를 판단하여 검출을 표시함으로써 진단율을 개선시킬 수 있도록 하였다. 본 논문은 흉부 X-ray 영상에서의 폐 결절을 추출하는데 유전자 알고리즘(Genetic Algorithm)을 이용한 템플릿 매칭(Template Matching) 방법을 제안한다. 제안한 방법은 흉부 X-ray 영상에 존재하는 결절과 레퍼런스 이미지를 매칭시켜 적합도를 계산한 후, 그 값을 통하여 수치가 낮은 개체를 선택하여 높은 개체와 교차시킨다. 그리고 레퍼런스 이미지는 결절이 존재하는 환자 X-ray 영상에서 샘플 노듈을 추출한 후 가우시안 분포를 갖는 512개의 레퍼런스 이미지를 생성하였다. 본 논문에서 사용된 영상은 결절 50개, 비결절 30개와 흉부 X-ray 영상에서 육안으로 판별이 가능한 결절 영상을 20개를 포함하여 총 100개 영상을 사용하였다. 실험 결과 83%의 결절을 자동 추출 하였으며, 가장 적절한 레퍼런스 이미지를 발견하고 이를 흉부영상에 매칭시켜 정확한 결절의 위치를 확인하였다.

  • PDF

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

A Development of the Automated System for Adjusting the Hexapod Circular Fixator (6자유도 원형체외고정기 조정을 위한 자동화 시스템 개발에 관한 연구)

  • Jung S. G.;Park B. S.;Sim H. J.;Han C. S.;Han J. S.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.505-510
    • /
    • 2004
  • In this article, we present an automated system for adjusting the 6 degree of freedom (D.O.F.) circular fixator. The system includes a scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut with the ability of the multiple synchronized motion and independent motion. The HCF was designed to control a 6 D.O.F. Ilizarov fixator and it's mechanism. The HCF adjustment software evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF adjustment software feed into the automated strut system which provides the scheduled adjustment. Then, the automated strut is synchronized by input data. Also the data of HCF adjustment software can be used to adjust HCF without automated struts. The proposed HCF system was verified by experiments.

Deep Learning-based Automated Detection of Radio-Opaque Markers in X-Ray Images (딥러닝 기반 방사선 비투과성 표지자 자동 검출 기법)

  • Song, Youngmin;Lee, Byoung-Dai
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.06a
    • /
    • pp.40-43
    • /
    • 2017
  • 본 논문은 딥러닝을 이용하여 대장통과시간(Colon Transit Time, CTT) 검사를 위한 단순복부 X-Ray 영상에서 방사선 비투과성 표지자(Radio-opaque Marker)를 자동으로 검출하는 기법을 제시한다. 대장통과시간 검사는 대장의 운동질환을 평가하는데 있어 가장 기본적인 방법으로 특히 만성 변비증 환자의 병태생리에 따른 유형 분류와 치료 계획을 설정하는데 큰 도움을 주고 있으며, 내과적 또는 외과적 치료 후 평가에도 유용한 검사이다. 대장통과시간 검사는 방사선 비투과성 표지자가 내재되어 있는 캡슐을 복용한 뒤 주기적으로 단순복부 X-Ray 촬영을 통해 구간별로 남아있는 표지자의 수를 세고, 이를 통해 구역별 통과시간을 측정한다. 이 과정에서 판독의가 직접 표지자의 위치 및 개수를 세기 때문에 많은 시간이 필요하게 된다. 따라선 본 논문에서는 이러한 단점을 보완하기 위해 딥러닝 기법을 사용하여 X-Ray 영상 내에서 표지자의 위치를 자동 파악하는 기법을 제시한다.

  • PDF

Automated 2D/3D Image Matching Technique with Dual X-ray Images for Estimation of 3D In Vivo Knee Kinematics

  • Kim, Yoon-Hyuk;Phong, Le Dinh;Kim, Kyung-Soo;Kim, Tae-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.431-435
    • /
    • 2008
  • Quantitative information of a three dimensional(3D) kinematics of joint is very useful in knee joint surgery, understanding how knee kinematics related to joint injury, impairment, surgical treatment, and rehabilitation. In this paper, an automated 2D/3D image matching technique was developed to estimate the 3D in vivo knee kinematics using dual X-ray images. First, a 3D geometric model of the knee was reconstructed from CT scan data. The 3D in vivo position and orientation of femoral and tibial components of the knee joint could be estimated by minimizing the pixel by pixel difference between the projection images from the developed 3D model and the given X-ray images. The accuracy of the developed technique was validated by an experiment with a cubic phantom. The present 2D/3D image matching technique for the estimation of in vivo joint kinematics could be useful for pre-operative planning as well as post-operative evaluation of knee surgery.

duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector (픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작)

  • Seung Ik, Jun;Bong Goo, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.969-974
    • /
    • 2022
  • In order to maximize dynamic range and to minimize image lag in digital X-ray imaging, diminishing residual parasitic capacitance in photodiode in pixels is critically necessary. These requirements are more specifically requested in dynamic X-ray imaging with high frame rate and low image lag for industrial 2D/3D automated X-ray inspection and medical CT imaging. This study proposes duoPIXTM X-ray imaging sensor for the first time that is composed of reset thin film transistor, readout thin film transistor and photodiode in a pixel. To verify duoPIXTM X-ray imaging sensor, designing duoPIXTM pixel and imaging sensor was executed first then X-ray imaging sensor with 105 ㎛ pixel pitch, 347 mm × 430 mm imaging area and 3300 × 4096 pixels (13.5M pixels) was fabricated and evaluated by using module tester and image viewer specifically for duoPIXTM imaging sensor.

A development of the automated system for adjusting the 6 D.O.F circular fixator

  • Jung, Sang-Gil;Park, Bum-Seok;Sim, Hyung-Joon;Jang, Jae-Ho;Han, Chang-Soo;Han, Jung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1642-1647
    • /
    • 2004
  • In this article, we present the development of the automated system for adjusting the 6 D.O.F circular fixator. The system includes scheduling software to adjust the Hexapod Circular Fixator (HCF) and an automated strut system with the ability of the multiple synchronized motion. HCF was designed to control a 6 degree-of-freedom Ilizarove fixator and it's mechanism is known as the Stewart Platform. HCF scheduler evaluates each value of altered length of the HCF struts to correct the complex skeletal deformity by using the X-ray data of the patient. The data of HCF scheduler feed into the automated strut system which be able to provide the scheduled adjustment and the automated strut is synchronized by input data.

  • PDF

Improved X-ray Center Beam Alignment Evaluation Method (개선된 X선 중심선속정렬평가 측정법)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.827-832
    • /
    • 2020
  • X-ray equipment, which is frequently used in radiology and treatment, is the most common and most used equipment in clinical practice. Equipment must provide accurate information to patients through continuous quality control. In case of manual quality control measurement, reproducibility may be poor and there may be a problem with reliability of evaluation results. In this study, an automated program was developed and attempted to measure how much the central ray between the focus of the X-ray tube and the variable aperture of the diagnostic X-ray generator used in clinical practice coincides. As a result of the experiment, it succeeded in calculating the coordinates of the two center points, and the distance between the two points was calculated in pixels and applied to the judgment and the automatic judgment value for whether the center line coincidence is within the normal angle or the abnormal angle is presented. The results of this study are considered to be very helpful in the quality control of the X-ray apparatus.

Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test (PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석)

  • Kim, Myungsoo;Kim, Giyoon;Lee, Minju;Kang, Dong-uk;Lee, Daehee;Park, Kyeongjin;Kim, Yewon;Kim, Chankyu;Kim, Hyoungtaek;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.