• Title/Summary/Keyword: Automated Program

Search Result 452, Processing Time 0.024 seconds

Challenges and suggestions in dealing with flexible space in predicting space utilization

  • Chen, Xingbin;Kim, Tae Wan
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.299-303
    • /
    • 2015
  • Flexible space is an adaptable space that has been increasingly used in many office and academic buildings as it increases the use of the space available and reduces the unnecessary building area. However, the architectural, engineering and construction (AEC) industry lacks a formalized method that helps architects predict and update the space utilization of flexible space during the project development, as such prediction aims to maximize the use of the building space available without exceeding the target utilization policy. Consequently, current manual utilization prediction results in lower accuracy level and limits the maximized use of the flexible space, which has multiple space-use types that affect the prediction of utilization. To address this problem, we identified eight space-use type differentiators (SUTDs) based on the literature review and observations and discussed the use of them in automated space-use analysis (SUA), which can predict the utilization of flexible space via a computer program. This research builds on SUA and contributes to flexible space planning by providing a means of a more comprehensive and accurate SUA.

  • PDF

Development of a New Lunar Regolith Simulant using an Automated Program Framework

  • GyeongRok Kwon;Kyeong Ja Kim;Eungseok Yi
    • Journal of Astronomy and Space Sciences
    • /
    • v.41 no.2
    • /
    • pp.79-85
    • /
    • 2024
  • Nowadays, the trend in lunar exploration missions is shifting from prospecting lunar surface to utilizing in-situ resources and establishing sustainable bridgehead. In the past, experiments were mainly focused on rover maneuvers and equipment operations. But the current shift in trend requires more complex experiments that includes preparations for resource extraction, space construction and even space agriculture. To achieve that, the experiment requires a sophisticated simulation of the lunar environment, but we are not yet prepared for this. Particularly, in the case of lunar regolith simulants, precise physical and chemical composition with a rapid development speed rate that allows different terrains to be simulated is required. However, existing lunar regolith simulants, designed for 20th-century exploration paradigms, are not sufficient to meet the requirements of modern space exploration. In order to prepare for the latest trends in space exploration, it is necessary to innovate the methodology for producing simulants. In this study, the basic framework for lunar regolith simulant development was established to realize this goal. The framework not only has a sample database and a database of potential simulation target compositions, but also has a built-in function to automatically calculate the optimal material mixing ratio through the particle swarm optimization algorithm to reproduce the target simulation, enabling fast and accurate simulant development. Using this framework, we anticipate a more agile response to the evolving needs toward simulants for space exploration.

Automation of Sampling for Public Survey Performance Assessment (공공측량 성과심사 표본추출 자동화 가능성 분석)

  • Choi, Hyun;Jin, Cheol;Lee, Jung Il;Kim, Gi Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.95-100
    • /
    • 2024
  • The public survey performance review conducted by the Spatial Information Quality Management Institute is conducted at the screening rate in accordance with the regulations, and the examiner directly judges the overall trend of the submitted performance based on the extracted sample. However, the evaluation of the Ministry of Land, Infrastructure and Transport, the evaluation trustee shall be specified by random extraction (Random Collection) is specified by the sample. In this study, it analyzed the details of the actual site and analyzed through securing actual performance review data. In addition, we analyzed considerations according to various field conditions and studied ways to apply the public survey performance review sampling algorithm. Therefore, detailed sampling criteria analysis by performance reviewers is necessary. A relative comparison was made feasible by comparing the data for which the real performance evaluation was performed with the outcomes of the Python automation program. This automation program is expected to be employed as a foundation program for the automated application of public survey performance evaluation sampling in the future.

Using automated container type culture system Hericium erinaceum mushroom production technology (컨테이너형 버섯식물공장시스템설계 및 노루궁뎅이버섯 생산)

  • Jo, Woo-Sik;Lee, Sung-Hak;Ryu, Song-Yi;Kang, Min-Gu;Kim, Woo-Hyun;Park, Chang-Min;Park, Who-Won
    • Journal of Mushroom
    • /
    • v.14 no.4
    • /
    • pp.249-252
    • /
    • 2016
  • Timing, place, and the high-tech industry to overcome barriers to the introduct of the so-called "smart agriculture". The core factors of precision agriculture, including temperature, humidity, location information, and real summary information, are all significant for ICT controlling technique. The system is a four-season container allowing mushroom product, humidity, illumination, and factors such as carbon dioxide were regulated to create the optimal environment for mushroom cultivation. Hericium erinaceum (also called Lion's Mane Mushroom, Bearded Tooth Mushroom, or Bearded Tooth Fungus) is an edible and medicinal mushroom in the tooth fungus group. During approximately 40 days of incubation, 1.4 kg of oak sawdust was used as the test medium. The humidity, temperature, and $CO_2$ density were maintained at >85-95%, $18-20^{\circ}C$, and 700-1,000 ppm, respectively, in the container type culture system. The time for primordium formation was observed to be 4-7 days. The amount of fruitbody production was 74-95 g per bag. This technique will be used to establish a new community support program, in conjunction with international movement, domestic sales and exports are also planned.

A Pre-Hospital Cardiac Arrest Patient Surviving after Dispather-Assisted Defibrillation by an Untrained Witness (응급의료전화상담원의 도움에 의해 교육 받지 않은 목격자의 제세동 시행 후 생존한 병원 전 심정지 1례)

  • Kim, Jong-Ho;Moon, Jun-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.239-244
    • /
    • 2018
  • A 59-year-old man with no specific medical or family history complained of chest pain and became unconscious. A member of his family, who was a witness, called 119 and gave him dispatcher-assisted cardiopulmonary resuscitation, followed by defibrillation using an automated external defibrillator placed in his apartment. Afterward, he was given two sessions of defibrillation by the 119 emergency squad, then transferred to an emergency medical center with the return of spontaneous circulation. The patient was discharged with cerebral performance category (CPC) 1 15 days later. While dispatcher-assisted cardiopulmonary resuscitation and defibrillation is at its beginning stage in South Korea, this case seems to demonstrate its effectiveness. Moreover, this case suggests it can be particularly useful for helping untrained witnesses use an automated external defibrillator, which may have important implications in regions in which there are delayed responses of the 119 emergency squad to the site. It is also important to develop a plan for improving witness access to and quantitative supply of the South Korean public access defibrillation (PAD) program.

An Improved Technique of Fitness Evaluation for Automated Test Data Generation (테스트 데이터 자동 생성을 위한 적합도 평가 방법의 효율성 향상 기법)

  • Lee, Sun-Yul;Choi, Hyun-Jae;Jeong, Yeon-Ji;Bae, Jung-Ho;Kim, Tae-Ho;Chae, Heung-Suk
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.12
    • /
    • pp.882-891
    • /
    • 2010
  • Many automated dynamic test data generation technique have been proposed. The techniques evaluate fitness of test data through executing instrumented Software Under Test (SUT) and then generate new test data based on evaluated fitness values and optimization algorithms. Previous researches and experiments have been showed that these techniques generate effective test data. However, optimization algorithms in these techniques incur much time to generate test data, which results in huge test case generation cost. In this paper, we propose a technique for reducing the time of evaluating a fitness of test data among steps of dynamic test data generation methods. We introduce the concept of Fitness Evaluation Program (FEP), derived from a path constraint of SUT. We suggest a test data generation method based on FEP and implement a test generation tool, named ConGA. We also apply ConGA to generate test cases for C programs, and evaluate efficiency of the FEP-based test case generation technique. The experiments show that the proposed technique reduces 20% of test data generation time on average.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Development and Assesment of an Embedded Portable A-ABR System (임베디드 기반의 휴대용 A-ABR 시스템 개발 및 평가)

  • Noh, Hyung-Wook;Nam, Ki-Chang;Jang, Kyung-Hwan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.3
    • /
    • pp.48-55
    • /
    • 2010
  • Hearing impairment is one of the most common birth defects among infants. Significant bilateral hearing impairment have profound effects on speech and language development. But it can be prevented, if a hearing impairment is identified and treated in its early stage. ABR (auditory brainstem response) is useful screening tool for new born hearing test. However, the interpretation of conventional ABR should be done by a experienced audiologist and testing takes some time. Therefore, A-ABR(automated ABR) which detect ABR peak automatically have been developed recently. In contrast to A-ABR researches became active in overseas, there has been little study in Korea. In this study, we have developed a portable A-ABR system based on the results of our previous study. For the evaluation of the developed system, the clinical trials were performed on adults and infants. As a results, it showed good sensitivity (94.4%) and specificity (92.2%), and accuracy (93.0%) between clinical diagnosis and the developed A-ABR test.

Determination of Spatial Resolution to Improve GCP Chip Matching Performance for CAS-4 (농림위성용 GCP 칩 매칭 성능 향상을 위한 위성영상 공간해상도 결정)

  • Lee, YooJin;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1517-1526
    • /
    • 2021
  • With the recent global and domestic development of Earth observation satellites, the applications of satellite images have been widened. Research for improving the geometric accuracy of satellite images is being actively carried out. This paper studies the possibility of automated ground control point (GCP) generation for CAS-4 satellite, to be launched in 2025 with the capability of image acquisition at 5 m ground sampling distance (GSD). In particular, this paper focuses to check whether GCP chips with 25 cm GSD established for CAS-1 satellite images can be used for CAS-4 and to check whether optimalspatial resolution for matching between CAS-4 images and GCP chips can be determined to improve matching performance. Experiments were carried out using RapidEye images, which have similar GSD to CAS-4. Original satellite images were upsampled to make satellite images with smaller GSDs. At each GSD level, up-sampled satellite images were matched against GCP chips and precision sensor models were estimated. Results shows that the accuracy of sensor models were improved with images atsmaller GSD compared to the sensor model accuracy established with original images. At 1.25~1.67 m GSD, the accuracy of about 2.4 m was achieved. This finding lead that the possibility of automated GCP extraction and precision ortho-image generation for CAS-4 with improved accuracy.

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF