• 제목/요약/키워드: Autoignition temperatures (AITs)

검색결과 36건 처리시간 0.021초

오토자일렌과 노말펜탄올 계의 최소자연발화온도 측정 (Measurement of Autoignition Temperature of o-Xylene+n-pentanol System)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.66-72
    • /
    • 2006
  • An accurate knowledge of the AITs(autoignition temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The measurement of AITs are dependent upon many factors, namely initial temperature, pressure, vessel size, fuel/air stoichiometry, catalyst, concentration of vapor, ignition delay time. The values of the AITs used process safety are normally the lowest reported, to provide the greatest margin of sefety. This study measured the AITs of o-xylene+n-pentanol system from ignition delay time by using ASTM E659-78 apparatus. The experimental AITs of o-xylene and n-pentanol were $480^{\circ}C\;and\;285^{\circ}C$, respectively. The experiment AITs of o-xylene+n-pentanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation).

n-Propanol과 Formic acid계의 최소자연발화온도의 측정 (Measurement of Autoignition Temperature of n-Propanol and Formic acid System)

  • 조영세;하동명
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.64-69
    • /
    • 2013
  • 가연성 혼합물의 최소자연발화온도는 가연성액체의 안전한 취급을 위해서 중요한 지표가 된다. 본 연구에서는 ASTM E659 장치를 이용하여 가연성 혼합물인 n-Propanol과 Formic acid 계의 최소자연발화온도와 발화지연시간을 측정하였다. 2성분계를 구성하는 순수물질인 n-Propanol과 Formic acid의 최소자연발화온도는 각 각 $435^{\circ}C$$498^{\circ}C$로 측정되었다. 그리고 측정된 n-Propanol과 Formic acid 계의 최소자연발화온도는 제시된 식에 의한 예측값과 작은 평균절대오차에서 일치하였다. 그리고 n-Propanol과 Formic acid 계는 일부 혼합 조성에서 두 개의 순수물질 가운데 낮은 AIT보다 낮게 측정된 최소자연발화온도거동(MAITB, Minimum Autoignition Temperature Behavior)을 보이고 있다.

가연성물질의 자연발화온도 측정 및 예측 - 메탄올과 에탄올 - (Measurement and Prediction of Autoignition Temperature(AIT) of Flammable Substances - Methanol and Ethanol -)

  • 하동명
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.54-60
    • /
    • 2004
  • Flammable substances are frequently used chemical industry processes. An accurate knowledge of the ALTs(Autoignition Temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, ignition delay. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for methanol and ethanol. The A.A.P.E.(Average Absolute Percent Error) and the A.A.D.(Average Absolute Deviation) of the experimental and the calculated delay times by the AITs for methanol were 14.59 and 1.76 respectively. Also the A.A.P.E. and the A.A.D. of the experimental and the calculated delay times by the ATIs for ethanol were 8.33 and 0.88.

n-Propanol과 n-Octane 혼합물의 최소자연발화온도의 예측 (Prediction of Autoignition Temperature of n-Propanol and n-Octane Mixture)

  • 하동명
    • 한국가스학회지
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 2013
  • 화재 및 폭발 방호를 위해서 문헌에서의 최소자연발화온도 값을 사용하는 것이 일반적이다. 본 연구에서, n-Propanol+n-Octane 계의 최소자연발화온도는 ASTM E659 장치를 이용하여 발화지연시간으로부터 측정하였다. 2성분계를 구성하는 n-Propanol과 n-Octane의 측정된 최소자연발화온도는 각 각 $435^{\circ}C$$218^{\circ}C$ 였다. 그리고 두 개의 2성분계에서 측정된 발화지연시간은 제시된 식에 의한 예측된 발화지연시간과 적은 평균절대오차에서 일치하였다.

Ethylbenzene+n-hexanol 계와 ethylbenzene+n-propionic acid계의 최소자연발화온도의 측정 (Measurement of Autoignition Temperature of Ethylbenzene+n-hexanol and Ethylbenzene+n-propionic Acid Systems)

  • 하동명;이성진
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.33-40
    • /
    • 2007
  • 화재 및 폭발을 방호하기 위해서 최소자연발화온도는 제시된 낮은 값을 사용하는 것이 일반적이다. 본 연구에서는 ASTM E659-78 장치를 이용하여 가연성 혼합물인 ethylbenzene+n-hexanol 계와 ethylbenzene+n-propionic acid 계의 발화지연시간과 AIT 관계를 측정하였다. 2성분계를 구성하는 순수물질인 ethylbenzene, n-hexanol, n-propionic acid의 측정된 최소자연발화온도는 각각 $475^{\circ}C,\;275^{\circ}C\;and\;511^{\circ}C$였다. 그리고 두 개의 2성분계에서 측정된 발화지연시간은 제시된 식에 의한 예측된 발화지연시간과 적은 평균절대오차에서 일치하였다.

BTX(Benzene, Toluene, Xylenes)의 자연발화온도와 발화지연시간의 측정 (Measurements of Autoigniton Temperature(AIT) and Time Lag of BTX(Benzene, Toluene, Xylenes))

  • 하동명
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.45-52
    • /
    • 2006
  • The AITs(autoignition temperatures) describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are often used as a factor in determining the upper temperature limit for processing operations and conditions for handling, storage and transportation, and in determining potential fire hazard from accidental contact with hot surfaces. The measurement AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, time lag. Therefore, the AITs reported by different ignition conditions are sometimes significantly different. This study measured the AITs of benzene, toluene and xylene isomers from time lag using AS1M E659-78 apparatus. The experimental ignition delay times were a good agreement with the calculated ignition delay times by the proposed equations wtih a few A.A.D.(average absolute deviation). Also The experimental AITs of benzene, toluene, o-xylene, m-xylene and p-xylene were $583^{\circ}C,\;547^{\circ}C,\;480^{\circ}C,\;587^{\circ}C,\;and\;557^{\circ}C$, respectively.

n-Butanol과 n-Decane계의 최소자연발화온도 측정 및 예측 (Measurement and Prediction of Autoignition Temperature of n-Butanol + n-Decane System)

  • 하동명;홍순강
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.184-189
    • /
    • 2011
  • 본 연구에서는 ASTM E659 장치를 이용하여 가연성 혼합물인 n-butanol + n-decane 계의 발화지연시간과 AIT관계를 측정하였다. 2성분계를 구성하는 순수물질인 n-butanol과 n-decane의 측정된 최소자연발화 온도는 각 각 $340^{\circ}C$, $211^{\circ}C$였다. 그리고 n-butanol + n-decane계에서 측정된 발화지연시간은 제시된 식에 의한 예측된 발화지연시간과 적은 평균절대오차에서 일치하였다.

산(Acid)류의 자연발화온도와 방화지연시간의 관계 (Relationship between Autoigniton Temperature(AIT) and Ignition Delay Time for Acids)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.27-33
    • /
    • 2004
  • 화학물질의 최소자연발화온도의 정확한 지식은 산업화재를 예방하고 제어하는데 중요하다. 최소자연발화온도(AIT)는 화염이나, 스파크 없이 주위로부터 충분한 에너지를 받아서 스스로 점화할 수 있는 최저온도를 말한다. AIT는 실험 개시온도, 압력, 농도, 용기의 크기, 양론혼합비, 촉매, 증기의 농도, 발화지연시간 등 많은 인자에 영향을 받는다. 본 연구에서는 1994년에 제작된 ASTM E659-78 장치를 이용하여 산류(Acids) 발화지연시간과 AIT관계를 측정하였고, 실험에서 얻은 자료는 본 연구에서 제시한 예측 모델과 적은 오차 범위에서 일치하였다.

크실렌 이성질체의 인화점과 최소자연발화온도의 측정 (Measurement of Flash Points and Autoignition Temperatures for Xylene Isomers)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제13권4호
    • /
    • pp.40-45
    • /
    • 2009
  • MSDS 자료의 적정성을 고찰하기 위해 크실렌 이성질체에 대해 Pensky-Martens 밀폐식(ASTM D93), Setaflash 밀폐식(ASTM D3278), Tag 개방식(ASTM D1310), Cleveland 개방식(ASTM D92) 장치 등을 이용하여 인화점을 측정하였으며, 또한 최소자연발화온도는 ASTM E659-78장치를 사용하여 측정하고, 문헌값들과 한국산업안전보건공단의 MSDS 자료와 비교하였다. 그 결과, 측정된 인화점과 최소자연발화온도는 이들과 차이를 나타내어 안전의 목적을 위해 연소특성치 고찰이 필요함을 알 수 있었다.

  • PDF

벤젠의 위험성 평가를 위한 연소 특성치 고찰 (Investigation of Combustible Characteristics for Risk Assessment of Benzene)

  • 하동명
    • 한국안전학회지
    • /
    • 제24권5호
    • /
    • pp.28-33
    • /
    • 2009
  • The thermochemical parameters for safe handling, storage, transport, operation and process design of flammable substances are explosion limit, flash point, autoignition temperatures(AITs), minimum oxygen concentration(MOC), heat of combustion etc.. Also it is necessary to know explosion limit at high temperature and pressure. For the safe handling of benzene, lower explosion limit(LEL) at $25^{\circ}C$, the temperature dependence of the explosion limits and flash point were investigated. And the AITs for benzene were experimented. By using the literatures data, the lower and upper explosion limits of benzene recommended 1.3 vol% and 8.0 vol%, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for benzene, and the experimental AIT of benzene was $583^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of benzene is proposed. The values calculated by the proposed equations were a good agreement with the literature data.