• 제목/요약/키워드: Auto-feeding system

검색결과 38건 처리시간 0.017초

Auto-dump Design of Postharvest Bulk Handling Machinery System for Onions

  • Park, Jongmin;Choi, Wonsik;Kim, Ghiseok;Kim, Jongsoon
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.379-385
    • /
    • 2018
  • Purpose: Postharvest handling of onions (harvesting, cleaning, grading, cooling, storing, and transport) should be performed continually to reduce costs and improve quality. The purpose of this study is to a) determine the design parameters and operating conditions of anion auto-dumping that constitutes a key component of the postharvest bulk handling machinery system, and b) to perform a performance test with the auto-dump prototype system. Methods: Kinematic analyses and computer simulations of the auto-dump mechanism were applied to analyze the operating conditions and design parameters. Results: The optimum working condition for the auto-dump was determined from kinetic analyses. In addition, the interaction between the velocity of the hydraulic cylinder and the angular velocity of the auto-dump were analyzed in order to control the bulk handling machinery system. The acting forces and optimum operating conditions of the hydraulic cylinder were determined by analyzing the forces related to the mass of inertia of the auto-dump assembly during rotation. The method of controlling the feeding rate of onions in terms of the uniformity of the stacking pattern and the control of the entire system was better than the two-stage method of controlling the rotational speed of the auto-dump. Based on the performance test with the prototype for the auto-dump, the stacking pattern and rigidity of the system were analyzed. Conclusions: These results would be of great importance in the postharvest bulk handling machinery system for onions.

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

양식장용 자동 먹이공급시스템 설계 (Design of Auto Feed Supply System for Fish Farm)

  • 오진석;조관준
    • 한국항해항만학회지
    • /
    • 제33권10호
    • /
    • pp.709-713
    • /
    • 2009
  • 근해의 수질오염은 수산양식 산업에 큰 영향을 미친다. 이러한 문제점을 해결하기 위하여 근해에서 외해로 양식장이 이동하고 있다. 외해 양식장의 구축을 위해서는 자동먹이 공급장치 및 원격 관리 시스템이 필요하다. 본 논문은 해상의 양식장에서의 자동 먹이 공급 시스템에 관하여 설명하고자 한다. 어류는 수온 및 어체 중량에 따라 먹이를 먹는 양이 변화하며, 해상 양식장의 경우 육상에 비하여 온도 변화가 크게 일어난다. 본 논문은 수온 및 어체 중량에 따라 먹이량을 계산하고 자동으로 먹이를 공급하는 시스템을 연구하였으며 모형 실험을 통하여 먹이 공급 장치의 성능을 검증하였다.

LED 융합조명의 자동화 조립 시스템에서 전자동 매거진 피더에 관한 구조해석과 동특성 분석 (Structural and Dynamic Characteristic Analysis for Automatic Magazine Feeder in Automation Assembly System for LED Convergency Lighting)

  • 추세웅;정상화
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.23-33
    • /
    • 2018
  • In the general manual feeder of an LED lighting assembly system, many workers are needed to supply parts to the main conveyor. The automatic feeder for modern automation lighting assembly systems consists of a completely automated feeding system and a magazine system that supplies the parts automatically. A standardized LED panel and diffusion cover is stacked in the cartridge of the magazine system. The structural safety of the automatic feeding system with regard to handling the load from the panels and covers stored in the cartridge should be guaranteed. LED convergency lighting modules are assembled using two LED panels and one diffusion cover in an automatic feeder. In this study, the structural safety and fatigue life of the automatic feeder and magazine were analyzed by considering the load generated in the automatically assembled LED convergency lighting system. In addition, the dynamic behavior of each auto-feeding system and magazine delivery system was visualized, and the working process was evaluated via dynamic simulation using a virtual engineering method. A tack time table for automatic feeding systems was derived by developing a virtual prototype.

AT 급전계통 해석 알고리즘 연구 (A Study Algorithm of AT Feeding Systems)

  • 추동욱;김재철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권4호
    • /
    • pp.174-179
    • /
    • 2002
  • In this paper, the modified simulation algorithms of the Auto Transformer (AT) feeding electric train system were proposed. To obtain terminal voltage of train by using equivalent circuit or the AT feeding system, the iterative method is proposed for which determine the train voltages. The train voltages are iteratively calculated from the system voltage drop and line impedance. In the carte study, the proposed method is verified from actual operation data of the Kwa-Chon line. Also it is verified that the proposed method can be extent to the multi-train simulation tool. The terminal voltage of the multi-train can be calculated by using superposition principle and it is easily applied to the proposed method. Therefore, the proposed method can be a solution for the complexity of the circuit analysis in the existing methods.

AT 철도 급전계통에서의 고장점 표정 알고리즘 (Algorithm for Fault Location in AT Feeding Railway System)

  • 서재범;강상희;이승재;정병태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.333-335
    • /
    • 2001
  • In this paper, an algorithm for fault location in Auto Transformer(AT) Feeding Railway system is presented. If a fault occurs at the AT feeding circuits of electrical railway system, it is very important to find fault location and to remove it immediately for the purpose of ensuring safety for transportation. Because the characteristics of reactance-distance are not linear, only using one terminal signals to give fault distance is difficult. In this paper, first, using the KVL, 4 voltage equation are obtained. Secondly, eliminating voltage a distance equation which consists of currents at rail and line parameters including mutual effects.

  • PDF

AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구 (A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method)

  • 김민석;최승혁;이종우
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

AT 교류 철도급전계통 내 다수 열차 운행시 새로운 계통해석 알고리즘 연구 (Applying New Algorithm on AC Auto-Transformer Feeding System under Multiple Trains Operating)

  • 전용주;추동욱;전명수;임성정;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.712-719
    • /
    • 2000
  • This paper presents a new algorithm to analyze a train voltages of multi-trains in auto-transformer-fed AC railway systems, using electrical equivalent change. The train current will be divided into circulation and return currents, and these current values are the same. By evaluating each current independently, the result will be more precise. The train current flows through the all auto-transformer corresponding to track impedance. In analyzing the railway system, the algorithm is based on the K.C.L, K.V.L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that tile proposed method is easily applied.

  • PDF

철도 전력공급시스템에서의 고조파전류 확대현상에 관한 연구 (A Study on the Propagation of Harmonic Current in the Traction Power Supply System)

  • 오광해;창상훈;한문섭;이장무;신한순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.908-910
    • /
    • 1998
  • Modern AC electric car has PWM(Pulse Width Modulation) -controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit. As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current. The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

철도 급전시스템에서의 고조파 해석 및 대책 연구 (A Study on the Countermeasures to Suppress Harmonics in the Traction Power Supply System)

  • 오광해;이장무;창상훈;한문섭;김길상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.318-325
    • /
    • 1999
  • Modern AC electric car has PWM(Pulse Width Modulation)-controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit, As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF