• Title/Summary/Keyword: Auto Exposure Control

Search Result 42, Processing Time 0.017 seconds

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Epicardial Repair of Acute Atrioventricular Groove Disruption Complicating Mitral Valve Replacement - A case report - (승모판막치환술 후 발생한 급성 제1형 좌심실 파열에 대한 심외막적 봉합 - 1예 보고 -)

  • Cho, Kwang-Ree;Kang, Jae-Geul;Jin, Sung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.855-858
    • /
    • 2007
  • A left ventricular rupture might be one of the most disastrous complications after a mitral valve replacement. An acute atrioventricular groove rupture (type I) was detected in a 54-year-old female diagnosed with a mitral stenosis combined with severe tricuspid regurgitation. She had a prior medical history of an open mitral commissurotomy in Japan at 30 years ago. The surgical findings suggested that the previous procedure was not a simple commissurotomy but a commissurotomy combined with a posteromedial annuloplasty procedure. After a successful mitral valve replacement and a measured (De Vega type) tricuspid annuloplasty, the weaning from a cardiopulmonary bypass was uneventful. However, copious intraoperative bleeding from the posterior wall was detected and the cardiopulmonary bypass was restarted. Exposure of the posterior wall of the left ventricle showed bleeding from the atrioventricular groove 3 cm lateral to the left atrial auricle. Under the impression of a Type I left ventricular rupture, epicardial repair (primary repair of the Teflon felt pledgetted suture, continuous sealing suture using auto-pericardial patch and application of fibrin-sealant) was attempted. Successful local control was made and the patient recovered uneventfully. The patient was discharged at 14 postoperative days without complications. We report this successful epicardial repair of an acute type I left ventricular rupture after mitral valve replacement.