• Title/Summary/Keyword: Auto Exposure Control

Search Result 42, Processing Time 0.021 seconds

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

CMOS Image Automatic Exposure System With Real-time and Robustness Style for the Journal of Korean Contents (실시간성과 강건성을 갖는 CMOS 자동노출 시스템)

  • Choi, Wonseok;Kim, HeeSu;Kim, Jaehyun;Cho, Youngki;Choi, Sungho;Lee, Yongseon
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.1-13
    • /
    • 2020
  • There are many factors that influence the image quality of CMOS camera images, among which the image exposure time is an important factor. If the image exposure time is long, the entire image on the screen becomes brighter. If the exposure time is shorter, the entire image becomes darker. When photographing a still image, real time is not required because the automatic exposure system is given sufficient time to obtain an appropriate exposure time. However, if the surroundings and environment change rapidly like the black box of a driving car, the exposure time should be applied in response to real time. To this end, a robust automatic exposure system for real-time performance and ambient light environment is required. An automatic exposure system that has real-time capability and is robust against the ambient light environment is required. we designed a real-time control sysem capable of parallel operation processing through the design of an embedded system using zynq's logic and ARM core, and developed a real-time CMOS automatic exposure system that is robust to noise and converges to a desired target value within 66 ms through PID control.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

Development of a Self-Travelling Sprayer for a Greenhouse (I) - Self-travelling - (시설원예용 파이프 유도식 무인방제기 개발 (I) - 무인 주행시스템 -)

  • 김태한;장익주;강춘태
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.209-216
    • /
    • 1999
  • A self-travelling sprayer was developed to avoid the exposure of an operator to agricultural chemicals and exhaust gas, to improve safety and to increase working efficiency during the application and transport work in the greenhouses. This system consists of self-travelling system and the control system for application and safety device. The auto-spray car is equipped with a liquid chemical tank of 80l capacity. The travelling system adopted mechanical steering system which link mechanism of front wheel is guided by guide rollers. The sprayer travels along the guiding pipe which is set on the furrow in the greenhouses. The sprayer stops automatically applying and traveling when the liquid chemical tank becomes empty or when the sprayer reach the turning point. The spray booms swings in a vertical plane. The control system of safety devices controls the automatic stop of the sprayer when there is an obstacle on the traveling path, or when the battery becomes discharged. The auto-spray car traveled smoothly and steadily along the guide pipe during traveling straightly and turning on the ground.

  • PDF

A Study on the Quantitative Analysis Method through the Absorbed Dose and the Histogram in the Performance Evaluation of the Detector according to the Sensitivity Change of Auto Exposure Control(AEC) in DR(Digital Radiography) (DR(Digital Radiography)에서 자동노출제어장치의 감도변화에 따른 검출기 성능평가 시 흡수선량과 히스토그램을 통한 정량적 분석방법에 관한 연구)

  • Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.232-240
    • /
    • 2018
  • This study is to suggest a method to evaluate the detector performance using change of absorbed dose and histogram according to sensitivity change of Auto Exposure Control(AEC). The experiment site is skull, abdomen pelvis and the accuracy of the detector was evaluated by measuring the absorbed dose of the detector sensitivity S200, S400, S800, S1000. Also the dynamic range of the detector was evaluated through the histogram analysis. As a result, the absorbed dose decreased gradually as the sensitivity was set higher from S200 to S1000. And through the sensitivity histogram analysis, as the sensitivity of the skull is set higher, the amount of information at both ends of the histogram is lost. Abdomen and pelvis areas showed underflow phenomena in which the amount of information in the first part of the histogram was lost as the sensitivity was set higher. In conclusion, the detector accurately implemented the sensitivity change, but the dynamic range of the image due to the sensitivity change of the AEC due to the deterioration of the detector performance can not be realized properly and it was found that the evaluation through the absorbed dose and the histogram is useful when evaluating the performance of the detector.

Auto-Exposure Control using Loop-Up Table Based on Scene-Luminance Curve in Mobile Phone Camera (입.출력 특성곡선에 기초한 Look-Up Table 방식의 자동노출제어)

  • Lee, Tae-Hyoug;Kyung, Wang-Jun;Lee, Cheol Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • Auto-exposure control automatically calculates and adjusts the exposure for consecutive input image. Recently, this is usually controlled by the sensor gain, however, unsuitable control causes oscillation of luminance for sonsecutive input images, called as flickering. Also, in mobile phone cameras, only simple information, such as the average luminance value, can be utilized due to coarse performance. Therefore, this paper presents a new real-time AE control method using a Look Up Table(LUT) based on Scene-Luminance curves to avoid the generation of flickering. Prior to the AE control, a LUT is constructed, which illustrates the characteristic of outputs for input patches corresponding to sensor gains. The AE control is first performed by estimating a current scene as a patch using the proposed LUT. A new sensor gain is then estimated using also LUT with previously estimated patch. The entire estimation process is performed using linear interpolation to achieve real-time execution. Based on experimental results, the proposed AE control is demonstrated with real-time, flicker-free.

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

An Improved AE System for Mobile Digital Still Camera (모바일 디지털카메라 모듈에 대한 개선된 AE 알고리즘 구현)

  • Cho, Sun-Ho;Kim, Dong-Han;Park, Chong-Kug
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.426-431
    • /
    • 2008
  • In this paper, an improved AE system for digital still camera is proposed. AE system is auto exposure system to maintain optimized brightness of output image. But there is limitation for mobile devices to get high quality image with the conventional AE algorithm, because of organizational restriction of system. The conventional research has been studied only electronic shutter and AGC on the AE algorithm. In this paper, we suggest new AE algorithm included target setting, frame delay, Gamma Correction as well as electronic shutter and AGC to get high quality image. The proposed algorithm show improved result at control speed and ability of luminance expression.

Research for The Environmental Optimization of Dose and Image quality in Digital Radiography (디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구)

  • Lee, Kwang Jae;Kim, MinGi;Lee, Jong Woong;Kim, Ho Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.203-209
    • /
    • 2013
  • Digital Radiography (DR) has improved a quality of resolution based on a wide dynamic range, high detective quantum efficiency (DQE), and modulation transfer function (MTF), compared with film/screen(F/s). Unlike expectation that a low level of radiation can be used in examination, high level of signal to noise ratio(SNR) due to over-exposure caused increase of exposed dose to patients. Also, the auto exposure control (AEC) using Kilovolage(kVp) in F/S can cause over-exposure. Hence, in this study, we proposed a proper method for using DR, in which effect of tubing Kilovolage on device's image, DR MTF measurement with changes of tubing current (mA), and the quantitative evaluation of skull phantom captured images' PSNR were evaluated. Changes of contrast with tubing Kilovolage can be improved by retouching, and MTF changes according to tubing current(1.41~1.39 lp/mm in 50% area, and 3.19~2.8 lp/mm in 10% area) does not influence on resolution of image. As a result, high tubing Kilovoltage, and tubing current will be suitable to use of DR.

Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method (자동노출제어장치 센서적용을 위한 스크린 프린팅 제작방식의 고흡수율 광도전체 특성평가)

  • Kim, Dae-Kuk;Kim, Kyo-Tae;Park, Jeong-Eun;Hong, Ju-Yeon;Kim, Jin-Seon;Oh, Kyung-Min;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • In diagnostic radiology, the use of automatic exposure control device is internationally recommended for diagnosis and optimization. However, if exposed to prolonged radiation is a complicated manufacturing process, there is a problem that occurs decrease of various performance overall brightness sensor, which is commercially available conventional. Therefore, in this study, absorption of X-ray is high, and I want to evaluate the AEC applicability of the sensor of the photoconductor-based production has an easy advantage. Experimental results confirms the possibility of fabrication of the sensor through an increase in the SNR, with the detection efficiency superior, accurate turn-off. In addition, it is confirmed that the experimental results of the transmittance and the latent image, Ghost effect by the light conductor does not appear, in the case of a photoconductor with the exception of the PbO, 80% - and it was confirmed good transmittance of 90%. Therefore, excellent mechanical stability and poor performance due to a change of the doping concentration than the existing products that have been put to practical use, the sensor easy photoconductor based, fabrication and can be applied as AEC sensor is expected.