Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • v.65 no.2
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

Development of an Automatic Blood Pressure Device based on Korotkoff Sounds

  • Li, Xiong;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.8 no.2
    • /
    • pp.227-236
    • /
    • 2019
  • In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.

Automatic blood pressure measurement device using oscillometric method and Korotkoff sounds

  • Wei, Ran;Lim, Young Chul;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.1 no.2
    • /
    • pp.20-25
    • /
    • 2012
  • The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Implementation of the Potable Blood Pressure Measurement System Using Wireless Communication Technology and MAA Algorithm (무선통신기술과 MAA 알고리즘을 이용한 휴대형 혈압측정 시스템 구현)

  • Kim, Bo-Sung;Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.678-681
    • /
    • 2007
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed. The system were composed of pressure control, signal measurement, blood pressure signal processing units and wireless sensor network parts. For verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Viral Patterns and Clincal Analysis of Acute Respiratory Tract Infections of Children in Korea(September, 1998~August, 2002) (바이러스에 의한 소아 급성 하기도 감염의 유행 및 임상양상(1998년 9월~2002년 8월))

  • Lee, Su-Jin;Park, Eun-Young;Oh, Phil-Soo;Lee, Kon-Hee;Kim, Kwang-Nam;Lee, Kyu-Man
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.1
    • /
    • pp.102-113
    • /
    • 2003
  • Purpose : Acute respiratory tract infections are the most common illnesses in children. The great majority of these infections involving lower respiratory tracts infections(LRTI) are caused by respiratory viruses such as respiratory syncytial virus(RSV), parainfluenza virus (PIV), influenza virus(INF), adenovirus(ADV), etc. Our purpose of this study was to examine the seasonal occurrence, clinical and laboratory features of each viral infections. Methods : Nasopharyngeal aspirates(NPA) were collected from 913 hospitalized children on the first day of admission. They were all admitted to Hangang Sacred Heart hospital and diagnosed as LRTIs. The study period was from September 1998 to August 2002. Specimens were inoculated onto HEp-2 cell, LLC-MK2 cell and MDCK cell. Viruses were detected by immunofluorescent method performed at day 10 postinoculation. Respiratory viruses were detected in 251(27%) cases. Medical records of 208 cases diagnosed as acute LRTIs were all taken reviewed and analyzed. Results : The identified pathogens were RSV 122 cases(58%), PIV 30 cases(14%), INFA 20 cases(10%), INFB 21 cases(11%) and ADV 15 cases(7%) during the study period. Outbreaks of RSV infections occurred every year but mostly on December, 1998 and November, 1999. LRTIs by PIV and ADV occurred during all seasons of the year. INFA was isolated moslty on March, 1999 and January, 2000. INFB infections occurred largely on April, 2002. The clinical diagnoses were bronchiolitis 88 cases(43%), pneumonia 87 cases(42%), croup 19 cases(9%) and tracheobronchitis 14 cases(6%). Common symptoms and signs were cough, rhinorrhea, sputum and fever. WBC counts in peripheral blood showed normal findings in 123 cases(59%). Each viral infections also showed some differences in auscultatory findings and chest X-ray findings. Conclusion : We learned that viruses are one of the major and important etiologic agents of acute LRTIs of children in Korea. However, we still need to find out more about its characteristic clinical features and continue studying on their seasonal occurrence to focus on their management and also prevention.

  • PDF