• 제목/요약/키워드: Auscultatory

검색결과 18건 처리시간 0.031초

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • 제65권2호
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

Development of an Automatic Blood Pressure Device based on Korotkoff Sounds

  • Li, Xiong;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • 제8권2호
    • /
    • pp.227-236
    • /
    • 2019
  • In this study, we develop a Korotkoff sound based automatic blood pressure measurement device including sensor, hardware, and analysis algorithm. PVDF-based sensor pattern was developed to function as a vibration sensor to detect of Korotkoff sounds, and the film's output was connected to an impedance-matching circuit. An algorithm for determining starting and ending points of the Korotkoff sounds was established, and clinical data from subjects were acquired and analyzed to find the relationship between the values obtained by the auscultatory method and from the developed device. The results from 86 out of 90 systolic measurements and 84 out of 90 diastolic measurements indicate that the developed device pass the validation criteria of the international protocol. Correlation coefficients for the values obtained by the auscultatory method and from the developed device were 0.982 and 0.980 for systolic and diastolic blood pressure, respectively. Blood pressure measurements based on Korotkoff sound signals obtained by using the developed PVDF film-based sensor module are accurate and highly correlated with measurements obtained by the traditional auscultatory method.

Automatic blood pressure measurement device using oscillometric method and Korotkoff sounds

  • Wei, Ran;Lim, Young Chul;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • 제1권2호
    • /
    • pp.20-25
    • /
    • 2012
  • The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.

Replacing Mercury Sphygmomanometers With Mercury-Free Sphygmomanometers for the National Health Survey in Children: Direct Comparisons Applying Two Types of Mercury-Free Sphygmomanometer

  • Sung Hye Kim;Yu-Mi Kim;Seong Heon Kim;Jinho Shin;Eun Mi Lee
    • Korean Circulation Journal
    • /
    • 제54권5호
    • /
    • pp.270-287
    • /
    • 2024
  • Background and Objectives: Blood pressure (BP) measurement using an auscultatory sphygmomanometer is recommended for diagnosing hypertension in children. As mercury sphygmomanometers (MSs) are banned owing to environmental concerns, it is crucial to determine the accuracy of mercury-free sphygmomanometers to replace them. We analyzed the accuracy of these devices to guide the National Survey selection. Methods: BP was measured thrice each with MS, auscultatory device (AD), and oscillometric device (OD) in 104 participants aged 10-18 using the National Survey data. The difference in BP was defined as the difference between MS and other devices. The BP differences, correlations, and influencing factors were analyzed. The frequencies of hypertension were also compared. Results: Systolic BP (SBP) and diastolic BP (DBP) differences between MS and AD were 0.88±3.36 mmHg and 0.63±3.95 mmHg, and those between MS and OD were 0.43±5.83 mmHg and 4.57±6.89 mmHg, respectively. The absolute error of <10 mmHg for DBP between MS and OD was 76%. The concordance correlation coefficient between MS and AD was 0.94 for SBP and 0.90 for DBP, and 0.81 and 0.67, respectively for MS and OD. Arm circumference negatively correlated with BP differences except for SBP between the MS and OD. The frequency of hypertension was not different between MS and AD but was underestimated by OD. Conclusions: AD correlated well with MS, while OD did not, especially for DBP. The superiority of AD over OD suggests AD as a possible alternative for MS in the National Survey.

누두흉의 임상적 고찰-14례 보고- (A Clinical Study of the Funnel Chest: Report of 14 Cases)

  • 이상호
    • Journal of Chest Surgery
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 1982
  • Fourteen cases of funnel deformity, 11 were male and the others female, treated over a eleven-year period, are presented. The overall results with the methods described by the authors, Wada, Shannon, Adkins and Ravitch appear to be excellent. The symmetric depression was more common In children under the age of 12 years and asymmetric one Increased after the age of 12. Six cases of abnormal cardiac auscultatory findings revealed no consistent hemodynamic abnormalities. An 21-year-old female was associated with left lung agenesis and dextroversion of the heart, and a 6-year-old boy with congenital bronchogenic cyst who underwent right upper lobectomy. EKG changes associated with the anomaly were observed in all. Pulmonary function test showed the range from normal to moderate restriction which did not Improve in only one patient after operation, but the patient did not complain any restriction In activity. Some transient complications were developed which resulted in improvement.

  • PDF

다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상 (Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals)

  • 정운모;심명헌;정상오;김민용;윤찬솔;정인철;윤형로
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

직접혈압측정치와 3가지 간접혈압측정치의 비교 (A Comparision of a Direct and Three Indirect Methods of Measuring Blood Pressure)

  • 이명화;박효경;손수경
    • 기본간호학회지
    • /
    • 제5권1호
    • /
    • pp.95-106
    • /
    • 1998
  • The purpose of this study was to compare direct and three indirect blood pressure measurements in adults and to compare among three indirect blood pressure measurements in adults. One direct(intraarterial) and three indirect(using a mecury sphygmomanometer, a aneroid type sphygmomanometer and an automatic auscultatory device) methods of blood pressure measurement were compared in adult patients who had an arterial line. The subjects for this study consisted of 29 patients in K medical center, B medical center, B hospital and M hospital in Pusan. The data was collected from October 1, 1992 to June 30, 1993. The collected data was analysed with the SPSS program, frequency, percentage, mean, S.D., t-test, ANOVA. The results of this study were as follows : 1) There was a significant difference in the systolic BP when using the direct and three indirect measurements(P<0.05). 2) There was no overall significant difference in the diastolic BP when using the direct and three indirect measurements. 3) There was no significant difference in the SBP and DBP among the three indirect measurements.

  • PDF

자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발 (A Simulator for the Validation of Non-invasive Blood Pressure (NIBP) Monitoring Devices)

  • 도일;임현균;안봉영;지영준;이종실;오재훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.111-115
    • /
    • 2017
  • Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device.

무선통신기술과 MAA 알고리즘을 이용한 휴대형 혈압측정 시스템 구현 (Implementation of the Potable Blood Pressure Measurement System Using Wireless Communication Technology and MAA Algorithm)

  • 김보성;김세진;정도운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.678-681
    • /
    • 2007
  • 본 연구에서는 오실로메크릭법에 의한 혈압측정을 위하여 비관혈적인 방법으로 보다 정확하게 혈압을 추정할 수 있는 시스템을 구현하였다. 구현된 혈압 측정 시스템은 압력 제어부, 신호 측정부 그리고 혈압 신호처리부, 무선센서네트워크부 등으로 구성하였다. 구현된 혈압측정 실험 시스템의 타당성을 검증하기 위하여 압력 측정부의 특성 평가 실험, 혈압 추정을 위한 특성비율 산출 실험, 오실로 메트릭법에 의한 혈압 추정 및 평가 실험을 수행하였다. 본 연구에서 구현된 혈압 측정 실험 시스템으로 성인남성 5명을 실험 대상군으로 선정하여 데이터를 계측하고 혈압을 추정하는 실험을 한 결과 오실로메트릭에 의한 혈압 추정 및 평가 실험에서 청진법과의 평균동맥압, 수축기 혈압, 그리고 이완기 혈압에서 최대 절대편차 비율이 각각 1.38 %, 1.63 그리고 2.97 % 이었고 최대 표준오차가 각각 5.00, 3.72, 그리고 4.34인 혈압 측정 시스템을 구현하였다.

  • PDF