• Title/Summary/Keyword: Auditory Stimulus

Search Result 112, Processing Time 0.018 seconds

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

Study on Human Physiological Responses to Emotional Lighting System using LED Flat Lighting (LED 면조명을 이용한 감성조명시스템의 인체 생리학적 반응에 관한 연구)

  • Kim, Kyung-Tae;Oh, Seung-Yong;Yu, Mi;Yu, Chang-Ho;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.29-38
    • /
    • 2014
  • The purpose of this study was to verify human physiological responses to emotional lighting system using LED (light emitting diode) flat lighting. Subjects were ten males in their twenties without medical history to eyes. Colors of LED lighting are red, orange, yellow, green, blue, purple and colorless (white). They were stimulated by LED lighting for 5 minutes. We measured body temperature, heart rate variability (HRV) and electroencephalogram (EEG) before and after color stimulus. In case of EEG analysis, relative power ${\alpha}$ wave ratio decreased in the groups of colorless, red and orange color light. Also, sympathetic nerve was more activated than parasympathetic nerve and the body temperature was increased in the groups of colorless, red, orange, yellow color light. On the other hand, relative power ${\alpha}$ wave ratio increased and parasympathetic nerve was more activated than sympathetic nerve and the body temperature was decreased in the groups of green, blue and purple color light. The results imply that the LED color lighting system in the realistic experiment environment. In the future, studies with compounded both colors and modes according to situation or auditory as nature sound or olfactory as aroma will be required.