• Title/Summary/Keyword: Attenuation of Noise

검색결과 479건 처리시간 0.028초

평탄부 선로에서 철도소음의 전파예측에 관한 연구 (A Study on the Predition of Train Noise Propagation from a Level Railroad)

  • 주진수;박병전
    • 소음진동
    • /
    • 제8권1호
    • /
    • pp.187-194
    • /
    • 1998
  • In order to predict the train noise propagation from a level railroad, this paper presents the model of train noise source and the prediction model based on the results by using the sound intensity method. The prediction model gives the effects of geometric attenuation, ground attenuation, and barrier attenuation of noise. There are several principal assumption in developing model: (a) the train noise is primarily rolling noise; (b) the rail head and wheels are in good condition; (c) the height of source is 10cm above track; (d) the directivity pattern of train noise sources is a dipole source. Calculated results based on this model are compared with available field data and good agreement has been obtained.

  • PDF

지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구 (A study of estimation for excess attenuation of Noise propagated on the ground)

  • 오재응;김동규;임동규
    • 한국음향학회지
    • /
    • 제7권2호
    • /
    • pp.20-25
    • /
    • 1988
  • 본 연구는 소음전파에 대한 옥외실험과 축적 음향모형실험에 의해서 지표면에 의한 초과감쇠 특징을 밝힌 것으로써, 옥외실험에 의한 소음전파감쇠는 음향출력이 큰 소형엔진을 사용하여, 거리감쇠로부터 산출한 실측의 초과감쇠와 Log(D/(Hs+Hr))의 관계를 확인했다. 그 결과 소음전파감쇠는 풍향, 주파수에 따라 다르며 직선회귀 된다는 것을 알 수 있었다. 그리고, 지표면상의 초과감쇠치는 통기저항을 이용해서 Log(D/Hs+Hr))을 파라미터로써 구할 수 있었고, 가장 적당한 통기저항$\sigma$는 실측의 초과감쇠치와 임의의 $\sigma$에 대한 $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ 식의 평균자승 오차가 가장 적어질 때 결정된다. 모형의 지표로써 축척 1/40의 모형실험으로, 큰 무향실내에서 거리감쇠의 측정을 한 결과, 실측치와의 대응이 충분하다는 것을 확인했다.

  • PDF

유동조건과 내부관 구명형상의 변화에 따른 소음기의 소음저감 특성 (Characteristics of Noise Attenuation with the Variation of Flow Condition and Hole Shape of Perforated Intruding Tues in Muffler)

  • 정진년;김원진;조범례
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.87-93
    • /
    • 1999
  • To propose a useful modelling method for an actual muffler, the noise attenuation effects of muffler was investigated according to the flow condition and the hole shape of tubes. In this work, the finite element method was used to calculate the transmission loss of muffler, The noise attenuation characteristics of four different types of muffler in the hole shape of tubes were compared mutually to find a more simple equivalent model. Analytical results showed that the overall value of transmission loss increases and the peaks of transmission loss curve shift to the low frequency with mean flow for the given muffler, Also the noise attenuation characteristics of the equivalent model having the split holes is almost the same as those of the actual muffler having many circular holes.

  • PDF

수목의 소음감쇄효과 (Noise Attenuation Effects of Trees)

  • 김성일;오동하
    • 한국산림과학회지
    • /
    • 제83권3호
    • /
    • pp.400-409
    • /
    • 1994
  • 본 연구는 다양한 유형의 수림대가 갖는 소음감쇄효과를 측정하기 위하여 수행되었다. 차량통행이 빈번한 도로변 6개 조사지를 대상으로 측정한 결과 수림대의 소음감쇄효과를 확인하였다. 도로로부터 1m와 10m 상의 최대음압도의 차이는 10-15dB로 수림대의 속성에 따라 다소간의 차이를 보이고 있다. 초지를 대조구로 비교하였을 때 조사지 중에서 음압도의 최대차이는 밀생한 관목림에서 보이는 5dB 수준이다. 도로로부터 상향 경사면에 위치하는 조사지의 경우에는 오히려 대조구보다 소음감쇄 정도가 미미하였다. 연구를 통하여 분석된 제한된 정보와 국내외의 이전 연구결과를 토대로 단층 건물 주변의 10m 폭 방음수림대의 적절한 유형을 제시한다면 최소 3m 폭, 2m 수고의 밀식된 관목수림대와 앞뒤로 각각 3m 폭의 부드러운 초지의 조성을 들 수 있다. 위의 처방은 본 연구의 결과로 유추하여 볼 때 소음원인으로부터 발생되는 음압도를 15dB 이상 감소시킬 수 있을 것으로 판단된다.

  • PDF

도로교통소음의 전파특성 및 영향 (Propagation Characteristics and Effects of Road Traffic Noise)

  • 박준철;김윤신;강대준
    • 한국환경보건학회지
    • /
    • 제34권4호
    • /
    • pp.311-315
    • /
    • 2008
  • This study was performed to investigate propagation characteristics and effects of road traffic noise generated from vehicles. Noise levels of expressway and general road were measured at four points in a straight line based on distance from the road, and analyzed. The average noise level of expressway was 78.9 dBA at 5 m, 76.4 dBA at 10 m, 72.0 dBA at 20 m, 69.0 dBA at 30 m. That of general road was lower about $3.1{\sim}3.5\;dBA$ than that of expressway. There was no significant difference in distance attenuation between expressway noise and general road noise. The farer the distance from source is, the more the attenuation is. The influence range of noise is assessed by noise environmental standards or road noise limits. Noise levels of the time zone were measured at a boundary line of apartment to grasp noise variation by time. The time zone of lowest noises was $3{\sim}4$ a.m. and that of highest noise was $8{\sim}10$ a.m. Data recorded on tapes were analyzed to understand the characteristics of frequency because these characteristics are important factors to plan the noise reduction measures, namely path measures.

칼리머 증기발생기에서 물-소듐 반응에 의한 소음 발생과 수소 기포의 소음 흡수 (Noise Generation by Water-Sodium Reaction and its Absorption on Hydrogen Bubbles for KALIMER Steam Generator)

  • 김태준;;황성태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1829-1835
    • /
    • 2000
  • The experimental results of sodium-water reaction noise measurement in frequency range $1{/sim}200kHz$ are presented. The experiments of noise generation under the condition of sodium test facility, water leak rate $0.01{\sim}1.2g/s$ and temperature of sodium $250{\sim}500^{\circ}C$, were carried out. From theoretical study it is noted that the noise resonant attenuation on hydrogen bubbles in liquid sodium plays the significant role for leak noise spectra formation. Interaction of leak noise and hydrogen bubbles in sodium being accompanied by thermal, emission and viscosity energy dissipation was studied. Acoustic noise spectra were investigated from point of view of water leak detection in sodium/water steam generator. The results of sodium-water reaction noise absorption on hydrogen bubbles in liquid sodium by temperature $250{\sim}500^{\circ}C$ are presented. The theoretical model of noise absorption using the coefficients of attenuation was developed. From calculation the coefficients of attenuation were estimated.

  • PDF

두 개의 각주형 건물에 의한 도로교통소음의 감쇠에 관한 연구 (A Study on the Attenuation of Road Traffic Noise with two Pillar Buildings)

  • 김화일
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.69-76
    • /
    • 2003
  • When houses or buildings are adjacent to roads, with no effective prevention of road traffic noise, neighbors are exposed to it. It is important to understand the properties of sound propagation before taking a countermeasure against road traffic noise. It is easy to estimate the properties of sound propagation without obstacles, but very difficult and complex to estimate them with ones. The purpose of this study is to present a useful tool that can estimate the properties of sound propagation. In the beginning of this study, we investigated the attenuation of road traffic noise with two pillar buildings, and presented practical approximate calculation method, and verified that through scale model. The outcomes from this study are as follows : (1) Over second reflection sound waves can be ignored. (2) Diffraction sound waves that happen when reflection sound and first diffraction wave are projected at the wedge of other building can be ignored.

Duct ANC 시스템에서 2차음원 방향별 소음감소효과 (An attenuation effect of noise according to the direction of secondary sound source in duct ANC system)

  • 이형석;이응석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.497-502
    • /
    • 2008
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of secondary sound source in duct ANC system. Automobile exhaust noise was recorded at 800rpm. 3500rpm and 5000rpm of a diesel engine. Directions of loudspeaker(second sound source) can be exchanged to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for experimentation. DSP board with TMS320C6416 chip of Texas Instrument Co used to control adaptive ANC system. This ANC system is based on the single-channel FxLMS algorithm. In experiment result, when the loud speaker direction was $150^{\circ}$, the attenuation effect showed largely. In case of $90^{\circ}$ duct, the noise was a little increased. In case of $30^{\circ}$ duct, the noise was a little increased or decreased according to the frequency range and the sound pressure(dB) of exhaust noise to comply with engine rpm.

  • PDF

Duct ANC System에서 부가음원 방향별 소음감소효과 (Noise Attenuation Effect According to the Direction of Secondary Sound Source in Duct ANC System)

  • 이응석;이형석
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.251-260
    • /
    • 2009
  • In this paper, we studied on an attenuation effect of automobile exhaust noise according to the direction of canceling speaker in ANC system. Automobile exhaust noise was recorded at 800 rpm, 3500 rpm and 5000 rpm of a diesel engine. Directions of canceling speaker can be set to $30^{\circ}$, $90^{\circ}$ and $150^{\circ}$ against the primary noise flow by acrylic ducts to be made for the experimentation. DSP board with TMS320C6416 chip of Texas Instrument Co. used to control the ANC system. The algorithm of this ANC system applied the Filtered-x-LMS algorithm that is modified to compensate for a property of DSP input signal and the secondary-path effect. As an experiment result, the direction of canceling speaker was proved to influence the reduction effect of noise. The $150^{\circ}$ duct in the attenuation effect of noise showed a better result than the $90^{\circ}$ or $30^{\circ}$ duct.