• Title/Summary/Keyword: Attenuation of Noise

Search Result 480, Processing Time 0.03 seconds

Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method - (방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 -)

  • Kim, Chul-Hwan;Chan, Tae-Sun;Kang, Hee-Man;Jeon, Ki-Seong;Kim, Dong-Joon;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

Implementation of multi-channel active noise control systems for active barriers (능동방음벽을 위한 다중채널 능동소음제어 시스템의 구현)

  • Choi, Jung-Il;Cho, Hyun-Gi;Nam, Hyun-Do;Ahn, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2007-2008
    • /
    • 2011
  • In this paper, we implemented active noise control systems for active barriers with attenuation of road noise. And then we constructed by multi-channel audio systems and DAQ part, high performance DSP H/W. Active noise control firmware program was implemented for multi-channel off-line/on-line estimation methods for secondary path transfer functions and FIR/IIR filter structure main noise control algorithms. To evaluate performance of implemented systems, active barriers test bed was implemented and several experiments was performed by various noise cases.

  • PDF

Development of a Silencer for an Acoustic Enclosure of a Large Transformer (대형 변압기의 밀폐장치용 소음기 개발)

  • Lee, Jun-Shin;Lee, Wook-Ryun;Lee, Tae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.786-789
    • /
    • 2005
  • An acoustic total or partial enclosure is widely used to reduce the sound pressure level propagating from a noise source. However, the performance of the acoustic enclosure is decreased by its inherent limitations such as temperature rise or acoustic pressure build up inside the enclosed acoustic field. In general, a silencer is installed to overcome these limitations, for large amount of air can be exchanged through the silencers. In this reason, a parallel baffle type duct silencer with acoustic resonators is studied to reduce the transmitted noise from a transformer. In this silencer, the high frequency components of the transmitted noise over 360Hz are effectively absorbed by the parallel baffles and the other ones, 120 and 240 Hz, are reduced due to the presence of Helmholtz resonators. Large sound attenuation is achieved by applying the sound resonating barrier to the large transformers in a substation.

  • PDF

Analysis of C/N Variation of Ku Band Satellite Beacon Receiver According to Rain Attenuation (강우 감쇠에 따른 Ku 대역 위성 비콘 수신기 C/N 변화 해석)

  • Park, Dae-Kil;Lee, Kyung-Soon;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.415-419
    • /
    • 2018
  • This paper predicts and measures the C/N ratio of a beacon signal transmitted from geostationary orbit satellite KorSat 5A ($113^{\circ}E$) at a ground station located in Kimpo. Based on the ground stations, we compared the rain attenuation of the zone K of ITU-R and the rain attenuation which analyzed the domestic weather information. In ITU-R, the Korean rainfall characteristics are classified into zone K, but forecasting the rainfall intensity and attenuation of three adjacent cities based on the cumulative rainfall data per minute from 2013 to 2017. The calculation of rainfall path and attenuation is based on ITU-R recommendations. The change of the C/N according to the rainfall amount was confirmed through the 2 week satellite beacon signal C/N measurement. The predicted critical C/N was decreased to 12 dB at $A_{0.3}$. During the experiment, it was confirmed that it decreased up to 8 dB according to the concentrated rainfall.

Noise Reduction in Real-time Context Aware using Wearable Device (웨어러블 기기를 이용한 실시간 상황인식에서의 잡음제거)

  • Kim, Tae Ho;Suh, Dong Hyeok;Yoon, Shin Sook;Ryu, Keun Ho
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1803-1810
    • /
    • 2018
  • Recently, many researches related to IoT (Internet of Things) have been actively conducted. In order to improve the context aware function of smart wearable devices using the IoT, we proposed a noise reduction method for the event data of the sensor part. In thisstudy, the adoption of the low - pass filter induces the attenuation of the abnormally measured value, and the benefit was obtained from the situation recognition using the event data of the sensor. As a result, we have validated attenuation for abnormal or excessive noise using event data detected and reported by 3-axis acceleration sensors on some devices, such as smartphones and smart watches. In addition, various pattern data necessary for real - time context aware were obtained through noise pattern analysis.

Construction of acoustics laboratory on the basis of ISO regulations (ISO 음향시험동 설치사례)

  • Han, Hee-Gap;Kim, Kyong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.379-382
    • /
    • 2005
  • Recently, we founded acoustic research laboratory consist of five reverberation rooms on the basis of ISO regulations. Four kinds of experiment are possible in our laboratory such as sound transmission loss of wall, sound attenuation of suspended ceiling, absorption coefficient, reduction of transmitted impact sound by floor coverings. We are going to provide our customers with officially authorized acoustics data.

  • PDF

A Study on the Development of a New Muffler Component required in the Geometrically Constrained Space (제한된 공간에 맞는 새로운 소음기부품의 개발에 대한 연구)

  • 이정권;이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.76-81
    • /
    • 1982
  • To get minimum noise level by making full use of the constrained geometric space and being compatible with the minimum pressure-drop condition, 3-pipe through-flow system is designed by inserting a new pipe which is shaped a resonator in the cavity of 2-pipe system. As a result of the 1/3-octave-band frequency analysis for the noise reduction characteristics, this system is proved to have good sound attenuation effect in the high frequency region, so that it is found to be a useful component of a muffler.

  • PDF

Multiple Model Adaptive Active Control of Noise in a Duct (덕트 잡음 제거를 위한 다중 모델 적응 능동 소음 제어)

  • 남현도;정종대
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.56-59
    • /
    • 1992
  • Adaptive active attenuation of noise in a duct is considered. A duct is modelled when the acoustic feedback exists. The secondary path transfer function is estimated using multiple model approaches. An IIR structure is assumed for the control filter, and the recursive least mean squares algorithm is used to adjust the filter coefficients.

  • PDF

Development of Integrated HVAC Noise Analysis Program for Ships (선박용 통합 HVAC 소음해석 프로그램 개발)

  • Han, Ju-Bum;Hong, Suk-Yoon;Song, Jee-Hun;Kim, Nho-Seong;Chun, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.588-593
    • /
    • 2011
  • The Main design parameters of ship HVAC systems are pressure drop and noise analysis of ducts. The Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994), but NEBB's method is not suitable for the ship HVAC systems. In this paper, numerical analysis methods are used to develop a noise prediction method for the ship HVAC systems, especially for large ducts. To develop regression formula of attenuation of sound pressure level in large duct, Boundary Element Method(BEM) is used. Using dynamic loss coefficient which is suggested by ASHRAE fitting data base and numerical methods of HVAC noise analysis, integrated HVAC noise analysis of Program is developed. The developed program can present pressure drop and noise analysis of the ship HVAC systems. To verify the accuracy and convenience of the developed program, prediction of HVAC system for Semi-Submersible Drilling RIG is carried out and the results are compared with measurement of noise level during sea trial.

  • PDF

Utilizing Noise Mapping in Environmental Impact Assessment in a Downtown Redevelopment Area (도심지 재개발사업 환경영향평가시 소음지도 적용방안에 관한 연구)

  • Lee, Shi-Won;Park, Young-Min;Choi, Jin-Kwon;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1311-1317
    • /
    • 2005
  • In environmental Impact assessment, noise impact assessment usually consists of three stages-surveying the existing noise levels by measurements, predicting noise levels induced by construction works and predicting noise levels after the completion of a project. The distance-attenuation relation of a point source, which has been used to predict the noise level due to its simplicity does not consider complex acoustic phenomena like multi-reflection, -diffraction and -absorption due to complex topographic configuration of buildings and terrains. For the consideration of such physical complexities. a noise mapping tool is adopted to produce a series of noise maps, which are those for the present, tot the works of construction and for the future. For accurate noise mapping, acoustical and topographic Information is used. Standard sound power levels and directivities of various construction equipments are need and scheduling of construction processes and locations of the equipments should be provided. In the case of exceeding legal limit, mitigation measures are applied to satisfy the legal limits and subsequent noise map is obtained and checked.