• Title/Summary/Keyword: Attaching film

Search Result 39, Processing Time 0.024 seconds

Emission Characteristics of Encapsulated Organic Light Emitting Devices Using Attaching Film and Flat Glass (접착 필름과 평판 유리를 이용하여 봉지된 유기 발광 소자의 발광 특성)

  • Lim, Su Yong;Yang, Jae-Woong;Ju, Sung-Hoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.3
    • /
    • pp.111-115
    • /
    • 2013
  • To study the encapsulation method for large-area organic light emitting devices (OLEDs), OLED of ITO / 2-TNATA / NPB / $Alq_3$:Rubrene / $Alq_3$ / LiF / Al structure was fabricated, which on $Alq_3$/LiF/Al as protective layer of OLED was deposited to protect the damage of OLED, and subsequently it was encapsulated using attaching film and flat glass. The current density and luminance of encapsulated OLED using attaching film and flat glass has similar characteristics compared with non-encapsulated OLED when thickness of Al as a protective layer was 1200 nm, otherwise power efficiency of encapsulated OLED was better than non-encapsulated OLED. Encapsulation process using attaching film and flat glass did not have any effects on the emission spectrum and the Commission International de L'Eclairage (CIE) coordinate. The lifetime of encapsulated OLED using attaching film and flat glass was 287 hours in 1200 nm Al thickness, which was increased according to thickness of Al protective layer, and was improved 54% compared with 186 hours in same Al thickness, lifetime of encapsulated OLED using epoxy and flat glass. As a result, it showed the improved efficiency and the long lifetime, because the encapsulation method using attaching film and flat glass could minimize the impact on OLED caused through UV hardening process in case of glass encapsulation using epoxy.

Encapsulation Method of OLED with Organic-Inorganic Protective Thin Films Sealed with Metal Sheet (금속판으로 봉인된 유-무기 보호 박막을 갖는 OLED 봉지 방법)

  • Lim, Su yong;Seo, Jung-Hyun;Ju, Sung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.7
    • /
    • pp.539-544
    • /
    • 2013
  • To study the encapsulation method for heat dissipation of high brightness organic light emitting diode (OLED), red emitting OLED of ITO (150 nm) / 2-TNATA (50 nm) / NPB (30 nm) / $Alq_3$ : 1 vol.% Rubrene (30 nm) / $Alq_3$ (30 nm) / LiF (0.7 nm) / Al (200 nm) structure was fabricated, which on $Alq_3$ (150 nm) / LiF (150 nm) as buffer layer and Al as protective layer was deposited to protect the damage of OLED, and subsequently it was encapsulated using attaching film and metal sheet. The current density, luminance and power efficiency was improved according to thickness of Al protective layer. The emission spectrum and the Commission International de L'Eclairage (CIE) coordinate did not have any effects on encapsulation process using attaching film and metal sheet The lifetime of encapsulated OLED using attaching film and metal sheet was 307 hours in 1,200 nm Al thickness, which was increased according to thickness of Al protective layer, and was improved 7% compared with 287 hours, lifetime of encapsulated OLED using attaching film and flat glass. As a result, it showed the improved current density, luminance, power efficiency and the long lifetime, because the encapsulation method using attaching film and metal sheet could radiate the heat on OLED effectively.

An investigation on flow characteristics of two dimensional inclined wall attaching offset jet (단이 진 경사벽면에 부착되는 2차원 제트유동에 관한 연구)

  • 송흥복;심재경;윤순현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.52-66
    • /
    • 1998
  • An experimental study on the flow characteristics was performed for a two-dimensional turbulent wall attaching offset jet at different oblique angles to a surface. The flow characteristics were investigated by using a split film probe with the modified Stock's calibration method. The jet mean velocity, turbulent intensity, wall static pressure coefficient profiles, and time-averaged reattachment point were measured at the Reynolds number Re (based on the nozzle width, D) ranging from 17700 to 53200, the offset ratio H/D from 2.5 to 10, and the inclined angle .alpha. from 0.deg. C to 40.deg. C. The Correlations between the maximum pressure position, minimum pressure position, and reattachment point and offset ratios, and inclined angles are presented.

  • PDF

An Investigation on Heat transfer Characteristics of Inclined Wall Attaching Offest jet (경사진 벽부착 제트의 열전달 특성에 대한 연구)

  • 심재경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.200-209
    • /
    • 1998
  • Experiments have been conducted to determine heat transfer characteristics for a two-dimen-sional turbulent wall attaching offset jet at different oblique angles to a flat surface. The local Nusselt number distributions were measured using liquid crystal as a temperature sensor. Wall static pressure coefficient profiles were measured at the Reynolds number Re 53200(based on the nozzle width, D) the offset ratio H/D from 2.5 to 10 and the oblique angle a from $0^{\circ}$, to $40^{\circ}$ It is observed that the maximum Nusselt number point occurs slightly upstream of time-averaged reattachment point for all oblique angles. The correlations between the maximum Nusselt number and Reynolds number offset ration and oblique angle are presented.

  • PDF

Development of Plastic Film Type Water Level Sensor for High Temperature (고온용 플라스틱 필름 수위 센서 개발)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.124-128
    • /
    • 2019
  • In this paper, a high temperature plastic film type water level sensor was developed. The high temperature film type water level sensor was manufactured by attaching a copper film to a polyimide film which can be used for a long time at 250℃, by laminating process and patterning the electrode by etching process. For the performance evaluation of the developed film type water level sensor, the temperature dependence of the capacitance was measured, and the deformation was examined after standing for 8 hours in 150℃ air. The developed film type water level sensor can be used at up to 150℃, and can be applied to electric ports and steam devices.

An Investigation of Roughness Effects on 2-Dimensional Wall Attaching Offset Jet Flow (조도가 2차원 벽부착 제트유동에 미치는 영향에 관한 연구)

  • 윤순현;김대성;박승철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.219-230
    • /
    • 1995
  • The flow characteristics of a two-dimensional offset jet issuing parallel to a rough wall is experimentally investigated by using a split film probe with the modified Stock's calibration method. The mean velocity and turbulent stresses profiles in the up and down-stream locations of the wall-attachment regions are measured and compared with those of the smooth wall attaching offset jet cases. It is found that the wall-attachment region on the rough wall is wider than on the smooth wall for the same offset height and the jet speed. The position of the maximum velocity point is farther away from the wall than that for the smooth wall case because of the thick wall boundary layer established by the surface roughness. It is concluded that the roughness of the wall accelerates the relaxation process to a redeveloped plane wall jet and produces a quite different turbulent diffusion behavior especially near the wall from comparing with the smooth plane wall jet turbulence.

Convective heat transfer characteristics of a two-dimensional turbulent wall attaching offset jet (2차원 난류 벽부착제트의 대류열전달 특성)

  • Yun, Sun-Hyeon;Lee, Dae-Hui;Song, Heung-Bok;Kim, Dae-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3304-3312
    • /
    • 1996
  • An experimental study on the convective heat transfer characteristics was performed for a two-dimensional wall attaching offset jet(WAOJ). Thermochromic liquid crystal was used to measure the plate wall temperature. The Nusselt number was measured for Reynolds numbers from 6, 500 to 39, 000, and the offset ratios from 0.5 to 15. The maximum Nusselt number point coincides with the time-averaged reattachment point and Nusselt number decreases monotonically after the jet reattaches on the wall. In the recirculation region Nusselt number minimize near the upstream corner and then increases as X/D decreases to vanishes. This suggests the existence of secondary vortices, causing an additional mixing of the flow in the corner. The correlations between the local Nusselt number and Reynolds number, Re, offset ratio, H/D, and streamwise distance, X/D are presented.

An investigation on heat transfer effects of two dimensional plane jet attaching offseted obliqued wall (단이 진 경사벽면에 부착되는 2차원 평면제트의 열전달 효과에 관한 연구)

  • Yun, Sun-Hyeon;Lee, Dae-Hui;Sim, Jae-Gyeong;Song, Heung-Bok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1314-1325
    • /
    • 1997
  • Experiments have been conducted to determine the flow and heat transfer characteristics for a two-dimensional turbulent wall attaching offset jet at different oblique angles to a flat surface. The distributions of the wall static pressure coefficient and time-averaged reattachment position for various offset ratios and oblique angles have been measured. The local Nusselt number distributions on the plate surface were also measured using liquid crystal as a temperature indicator. The new hue-capturing technique utilizing a true color image processing system was used to accurately determine the temperature of the liquid crystal. The experiments were carried out at Reynolds number, Re (based on D) of from 7300 to 21,300 with offset ratio, H/D from 2.5 to 10, and oblique angle, .alpha. from 0 deg. to 400 deg..

Folate Contents of Oriental Melon (Cucumis melo) Cultivated in Greenhouse Covered with Different Films and Varieties (시설 피복자재와 품종에 따른 참외 엽산 함량)

  • Chun, Hee;Choi, Yeung-Ha;Um, Yeong-Cheol;Paek, Y;Yu, In-Ho;You, Hee-Yong;Hyun, Tai-Sun;Yon, Mi-Yong;Shin, Yong-Seub
    • Journal of Bio-Environment Control
    • /
    • v.17 no.1
    • /
    • pp.32-37
    • /
    • 2008
  • Light transmittance of PO-2 film was 71.2% higher than any other films, because of low amount of pending water and attaching dust on film surface. On dawn, the air temperature of tunnel were higher than that of outdoors as much as between 11.8 and $14.5^{\circ}C$ on Feb. 19 to 20, 2007. The air temperature in the greenhouse covered with PO-2 film was higher than any other films as much as $2.3^{\circ}C$. Analyzing of folate in oriental melon, the folate contents of fruit were between 68.9 and $113.4\;{\mu}g/100\;g$ according to varieties. In winter, the folate contents in the treatment of PO-2 film was higher than that in the treatment of PE film as much as 17%. Above $15^{\circ}C$ in outdoors mean air temperature, the folate contents were as much as between 55.2 and $75.2\;{\mu}g/100\;g$. The folate contents in the treatment of PO-2 film was higher than that in the treatment of PE film as much as 36%.

The Evaluation of Cooling Load by The Window Film Insulation in College Building (대학 건물에 적용한 열 차단 필름이 냉방부하에 미치는 영향 평가)

  • Kim, Seok-Hyun;Kang, Su-Hyun;Yu, Si-Wan;Cho, Young-Hum
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.549-552
    • /
    • 2012
  • Recently the world is trying to reduce carbon emissions for global warming. Reducing use of fossil fuels can decrease carbon emission. In this reason the construction field has tried to reduce the use of fossil fuels relating to heating and cooling of buildings. An energy loss through the window system is about 10 to 30 percent of energy consumption of the whole building. The use of window film insulation is increasing to control the heat loss at the windows. The window film insulation absorbs solar radiation and makes the surface temperature of windows high. In this study, window surface temperature is measured, and an impact on indoor air is identified after attaching window film insulation. Finally, we found that cooling load decreases through simulation.

  • PDF