• Title/Summary/Keyword: Attached material

Search Result 622, Processing Time 0.031 seconds

Histological Changes in the Normal Tissues of Rat after Local Application of the Holmium-166-Chitosan Complex attached to Biodegradable Solid Material (생분해성 고형물에 흡착시켜 실험동물에 국소 투여한 홀미움- 166-키토산 복합체의 투여량, 기간 및 부위에 따른 조직의 괴사 정도와 양상)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Cho, Wan-Hyung;Lee, Soo-Yong;Oh, Jung-Moon;Kim, Jin-Wook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • Purpose: The aim of this study was to find out a clinically appliable method to insert a biodegradable solid material containing holmium-166-chitosan complex into the surgical field, and to evaluate the histological changes in the normal tissues after ${\beta}$ -ray irradiation from holmium-166 according to the dose, period and type of tissues. Materials and Methods: 3.0 mCi, 50 ${\mu}l$ of the liquid state $^{166}$Ho-chitosan complex was attached to the absorbable gelatin sponge. The radiation activity measured by dose caliberator was 1.5 mCi. These $^{166}$Ho-chitosan complex containing absorbable gelatin sponges were inserted into the thigh muscles and over the femur bones of the Wistar rats. The cases were evaluated at 2 weeks after insertion, and 4, 6 weeks with respect to the histological changes of the soft tissues and bone, the depth of the tissue necrosis, and the changes of the $^{166}$Ho-chitosan complex containing absorbable gelatin sponges. Results: At 2 weeks, the muscles showed coagulation necrosis, degenerating myocytes, regenerating myocytes, intermuscular edema, and inflammatory cells. The necrosis depth was 3.3 mm. In the bones, there was no osteocyte in the lacuna of cortex (empty lacuna), marrow fibrosis, inflammation. The necrosis depth was 2.9 mm. At 4 weeks, in the muscle, calcification and increased fibrosis with necrosis depth by 3.3 mm were the additional findings. In the bone, marrow fibrosis with necrosis depth by 3.3 mm were detected. At 6 weeks, soft tissue shrinkage, increased fibrosis and granulation tissue formation, and nearly resolving inflammatory reaction were the findings. Conclusion: The local application of the $^{166}$Ho-chitosan complex attached to biodegradable gelatin material with surgery in the laboratory animals resulted in no mortality and morbidity, and satisfactory tissue necrosis. Holmium-166 can be applied to the treatment of the malignant tumor patients.

  • PDF

A study on design and structural strength analysis for the rake of rotary screeners (로터리 제진기의 Rake에 대한 설계 및 구조강도해석에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.210-215
    • /
    • 2017
  • This study examined the mechanical design and the structural strength analysis of the rake used in a rotary screener. For the case of the mid-water part, an additional load condition was given by calculating the underwater frictional force generated by the water. For the upper-water part, the analysis was done by dividing the 500kg additional load into the left-concentrated load, center-concentrated load, and right-concentrated load depending on the location of the attached narrow material, and it was determined that all 3 additional load conditions were free from plastic deformation and were secure. The additional load that can occur from the weight of the attached narrow material was divided into three, 1,000kg, 1,300kg, and 1,500kg, and then analyzed. The results of the analysis show that in the case of 1,000kg and 1,300kg, an equivalent strength of 143.6MPa and 186.6MPa occurred, respectively. These figures are lower than the yield strength of the STS304 used in the rotary screener. Therefore, plastic deformation does not occur and is considered to be secure. In the case of 1500kg, however, the equivalent strength that occurred was 215.41MPa, which is greater than the yield strength of STS304, and was judged to be unsafe.

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

Experimental Study on Long-term Characteristics of Sprayable Waterproofing Membrane (차수용 박층 멤브레인의 장기 성능 변화에 관한 실험 연구)

  • Choi, Soon-Wook;Kim, Jintae;Choi, Myung-Sik;Chang, Soo-Ho;Kang, Tae-Ho;Lee, Chulho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.15-23
    • /
    • 2019
  • The sprayable waterproofing membrane is a recently introduced material in the civil engineering field, and is a material that sprays and attaches a single phase or two phase powder or liquid material to a surface to be covered using a pump and nozzle. Although the material properties are gradually reported through researches, there is a lack of studies on long-term performance compared to concrete materials used with the membranes. In this study, the long-term performance of materials was estimated using the Arrhenius equation. The temperature conditions used in this study were 65℃, 80℃ and 95℃, and the temperature was maintained with the membrane attached to the concrete block for long-term behavior. Then the membranes were tested for tensile strength and adhesion strength in the order of 30, 90, 150, 200, and 300 days. The long-term performance of the material was determined from a long-term perspective by estimating the activation energy by the Arrhenius equation. Consequently, the time to reach 50% of the performance standard could be estimated by long-term test.

A Study on Development of Drying Method of Paddy Rice in Sack (포대단위 곡물건조방법의 개발에 관한 연구)

  • 서상룡;최재갑
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3980-3990
    • /
    • 1975
  • This study was carried out to develop a method of grain drying ststem that can be done by forcing the heated-air directly into the grains within the sack. The air duct was pushed into the central position of the grain-deposited sack and the heated-air was forced to flow in the radial direction. The system is referred here as the unit sack drying system. At a first step of this study, an air flow resistance tester was constructed to measure the resistance of air flow to grains in cooperated with some different sack materials, the sack materials, the tested were rice-straw bag, sack of polyethylene film, and jute sack In addition, unit sack drying system was constructed to investigate the drying characteristics of the dryer. on this dryer, two kind of terminal air ducts were attached and tested to examine its effects on uniform drying, and also, aseries of drying test was performed to trace the effect of increasing air flow rate on uniform drying. The results are as follows: 1) Resistance of air flow for each sack material was increased almost proportional to the increasing rate of air flow. Experimental data showed little significant differences of the air flow resistance among the materials. 2) From the comparison with air flow resistance of sack material and that of roughrice, it was indicated that airflow resistance of sack material was much higher than that of rice rough Therefore, in the unit sack drying sysle in which air flow is destined to face the sach material after leaving the grain, it was suggested that air flow would be inuniform to each part of grain within sack because of much higher air flow resistance of sack material than that of grain, and the fact would results inuniform grain drying. 3) Drying test on the unit sack drying system in cooperated with different type of terminal air ducts showed that high speed air is better for uniform drying than in high pressure. with the drying system which was assembled with the air ducts delivering higher speed air, there also involved a problem of significant inuniform drying. Therefore, any means to improve the inuniform drying should be undertaken for practical use. 4) A series of drying test with in creasing air flow rate resulted that increasing air flow rate in the unitsack drying system gave little effect on uniform drying, therefore, it is recommened to change its drying system for drying grain uniformly.

  • PDF

Studies on Adhesive Nonwovenfabrics for Padding Cloths (접착심지에 관한 연구)

  • 성화경
    • Journal of the Korean Home Economics Association
    • /
    • v.11 no.3
    • /
    • pp.276-284
    • /
    • 1973
  • An experiment, aimed at finding out the adhesive condition when adhesive non-woven fabrics for padding cloths are used for padding cloths of blouse, has been conducted. Materials used were three different kinds-scoured, sanforized, and permanent pressed- of combined fabrics of polyester and cotton. As for padding cloth material, mixed spinning nonwoven fabrics of polyster and viscose rayon have been used. Adhesive conditions were made each at $120^{\circ}C$, $140^{\circ}C$, $160^{\circ}C$ and $180^{\circ}C$, respectively, and adhesive time has been limited to 5, 10, 20, 30, 40 seconds each. External appearance as well as quality have been watched through washing experiment. In case of 12$0^{\circ}C$, all experimental materials were separated at the seventh washing and as for $140^{\circ}C$, all but the material which has been attached on scoured cloth for 40 seconds were separated. In case of 20 seconds only permanent pressed cloth and sanforized cloth were separated. At 30 and 40 seconds, the adhesive conditions have been maintained up to the seventh washing. In case of 5 seconds $180^{\circ}C$it was not turned yellow, but all were separated. In case of 10, 20, 30 and 40 seconds, at above temperature all were turned yellow in the adhesive process. Therefore, the adhesive power could be said strong enough, though it was not very practical. In this experiment, the lower the temperature of iron is, the longer time it has to be touched. At higher temperature however, relatively short time makesn it possible for adhesion and depending upon the finishing methode of cloth, there is slight difference in adhesive power. As a result, the best adhesive condition for all experimental materials is $160^{\circ}C$of iron temperature, and the time of adhesion is between 30 and 40 seconds.

  • PDF

Vibration Isolation Characteristics of CRP Materials and SNORE Ring on the Multi-Curved Structure (CRP 재질 및 SNORE 링 부착에 따른 다층 곡면 구조물의 진동 차단 특성 연구)

  • Lee, Jong-Kil;Jo, Chi-Yong
    • 대한공업교육학회지
    • /
    • v.35 no.2
    • /
    • pp.224-237
    • /
    • 2010
  • When the underwater structure sails high speed, noise and vibration propagate to the sensor in the nose of the dome. In this paper, to avoid this kind of noise and vibration CRP(Carbon Reinforced Plastic) material and SNORE ring(Self-NOise REduction Ring) are attached at the curved structure and simulates its isolation characteristics using commercial software. Vibration displacement and stress are calculated at the planar sensor array. The material of the curved structure is aluminum and maximum outer diameter is 53Omm, 215mm in length, 270mm in planar diameter, respectively. Based on the simulation results, reduction ratio of the received normal stress at the sensor is above 95% at the frequency of 12kHz and 15kHz. At the mid point of the planar sensor the normal stress is higher than 20mm and 40mm apart. This results can be used to increase the sensitivity of the acoustic sensor as a basic data.

  • PDF

A Study on the Actual Condition for Air Respirators Using Air-breathing (공기호흡기용 압축공기 시스템에 대한 실태 연구)

  • Lee Chang-Woo;Lee Young-Jae;Hyun Seong-Ho;Seong Jae-Man;Song Yun-Suk;Choi Don-Muk;Yoon Myung-O
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.16-21
    • /
    • 2004
  • This paper has investigated influences of pollutants in air-breathing on the respirators and it by year of disused air respirators that fire fighter is using in domestic cutting done air respirators after collection observed state of cylinder material through instrumental analysis, and cut open pipe to confirm pollution degree of pipe from cylinder of air respirators to airline mask and confirm pollution availability. The metal surface inside the air respirators was corroded by moisture included in the compressed air. The material generated by corrosion is white powder of less then 100㎛, which is analyzed as aluminum hydroxide corroded by moisture. This aluminum hydroxide powder may get into the lung while one breathes in, and it is easy to be attached to the lung so it will cause a serious influences to human health. This study suggests that Korea should set out the standards for components and composition of breathing air as soon as possible.

Development of NFC Mobile Application for Information on Textile Materials (패션소재 정보 전달을 위한 NFC 모바일 어플리케이션 개발)

  • Park, Sohyun;Kim, Jongjun
    • Journal of Fashion Business
    • /
    • v.20 no.1
    • /
    • pp.142-156
    • /
    • 2016
  • Convergence of IT devices and fashion is enabling the industry to take fully different approaches in various areas including product planning, fabric selecting, distributing, and marketing. At the same time, it also transforms the definition of clothing itself. Convergence of IT technologies in the realm of fashion and textiles industries can create a powerful synergy through connection digital devices, such as mobile phone. In this context, this study attempts to suggest how IT technology can be efficiently harnessed through the usage of mobile devices in the planning stage of fashion materials, where the initial production plan of a clothing item is mapped out. This study ultimately aims to enhance the effectiveness of databases on fashion material information by using mobile devices to utilize NFC, an RFID technology having as much revolutionary power as Internet - which can be the convergence between IT and fashion across the software dimensions. To pursue this research, data on fashion material information regarding 200 woven fabric specimens were provided by textile companies. The information includes elements such as its composition, weight, width, yarn, density and sales report. These pieces of information were organized into a database. Drawing on this data, Android-based applications that allow smart phones to read off fabric information from NFC tags were developed for this study using two methods. The system works as follows: 1. NFC tag stickers are attached onto the hangers where 200 fabric samples are hanging. 2. The NFC tag stickers are tagged, or read off from a smart phone that support NFC functions. 3. Upon tagging, the Smart phone swiftly displays all information available on its screen - not only the aforementioned six elements, but also the image of the clothing item from the fabric in its finalized product form, and the video of the model wearing the item - for convenient view. The method harbors immense potential for the fashion industry in general, and will also be useful in those fields inside the industry that harness NFC technology.