• Title/Summary/Keyword: Atomic emission

Search Result 643, Processing Time 0.029 seconds

Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide of before/after a Decoction (전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 감기약을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.23 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives: To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods: The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer(ICP-AES) and mercury analyzer. In order to analyze pesticides in 5 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents(mg/kg) for the samples were as follows: Galgeun-tang(before decoction-Pb; 0.793, Cd; 0.133, As; 0.016 and Hg; 0.005, after decoction-Pb; 0.033, Cd; 0.004, As; 0.002 and Hg; not detected), Gumiganghwal-tang(before decoction-Pb; 0.934, Cd; 0.197, As; 0.046 and Hg; 0.006, after decoction-Pb; 0.062, Cd; 0.007, As; 0.004 and Hg; 0.0001), Sosiho-tang(before decoction-Pb; 0.891, Cd; 0.134, As; 0.091 and Hg; 0.014, after decoction-Pb; 0.036, Cd; 0.002, As; 0.004 and Hg; not detected), Ojuck-san(before decoction-Pb; 0.907, Cd; 0.136, As; 0.084 and Hg; 0.007, after decoction-Pb; 0.074, Cd; 0.007, As; 0.011 and Hg; 0.0005) and Samsoeum(before decoction-Pb; 1.234, Cd; 0.154, As; 0.016 and Hg; 0.007, after decoction-Pb; 0.094, Cd; 0.006, As; 0.002 and Hg; 0.001). 2. Contents(mg/kg) of residual pesticides before/after a decoction in all samples were not detected. 3. Contents(mg/kg) of sulfur dioxide($SO_2$) before a decoction in Galgeun-tang, Gumiganghwal-tang, Sosiho-tang, Ojuck-san and Samsoeum exhibited 1.2, 3.4, 11.1, 12.0 and 5.7, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. Conclusions: These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

  • PDF

Influence of thickness ratio and substrate bias voltage on mechanical properties of AlCrN/AlCrSiN double-layer coating (두께 비율과 기판 바이어스 전압이 AlCrN/AlCrSiN 이중층 코팅의 기계적 특성에 미치는 영향)

  • Kim, Hoe-Geun;Ra, Jeong-Hyeon;Lee, Sang-Yul;Han, Hui-Deok
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.162-162
    • /
    • 2017
  • AlCrN 코팅은 높은 경도, 낮은 표면 조도 등의 상온에서의 우수한 기계적 특성 이외에 고온에서 안정한 합금상의 형성으로 인하여 우수한 내열성을 보이는 코팅이며, Si을 첨가하여 나노복합구조를 갖는 AlCrSiN 코팅은 고경도 특성을 나타내는 나노결정립과 고내열성을 나타내는 $Si_3N_4$ 비정질이 동시에 존재함으로써 뛰어난 고온 특성까지 보유하여 공구 코팅으로의 적용 가능성이 크다. 본 연구에서는, 가혹화된 공구사용 환경 대응 하는 더욱 우수한 내마모성 및 내열성을 보이는 코팅막을 개발하기 위해 AlCrN/AlCrSiN 이중층 코팅을 합성하였다. 합성된 코팅의 구조 및 물성을 분석하기 위해 field emission scanning electron microscopy(FE-SEM), nano-indentation, atomic force microscopy(AFM) 및 ball-on-disk wear tester를 사용하였다. 내열성을 확인하기 위하여 코팅을 furnace에 넣어 500, 600, 700, 800, 900도에서 30분 동안 annealing한 후에 nano-indentation을 사용하여 경도를 측정을 하였다. 5:5, 7:3, 9:1의 두께 비율로 AlCrN/AlCrSiN 이중층 코팅을 합성하였으며 모든 코팅의 두께는 $3{\mu}m$로 제어되었다. AlCrN 코팅층의 두께가 증가할수록, 이중층 코팅의 경도 및 내마모성은 점차 향상되었지만 코팅의 밀착력은 감소하였다. 일반적으로 AlCrN 코팅은 상대적으로 높은 잔류응력을 갖고 있으므로, AlCrN 층의 두께비율이 증가함에 따라 코팅내의 잔류응력이 높아져 코팅의 경도는 증가하고 밀착특성은 낮아진 것으로 판단된다. AlCrSiN 상부층 공정시 기판 바이어스 전압을 -50 ~ -200V 로 증가시키면서 이중층 코팅을 합성하였다. XRD 분석 결과, 공정 바이어스 전압이 증가함에 따라 AlCrSiN 상부층은 점차 비정질화 되었고, 코팅의 경도와 표면 특성이 향상되는 것을 확인하였다. 이러한 특성 향상은 높은 바이어스 인가가 이온 충돌효과의 증가를 야기시켰으, 이로 인해 치밀한 코팅층 합성에 의한 결과로 판단된다. AlCrN/AlCrSiN 이중층 코팅을 어닐링 한 후 경도 분석 결과, -150, -200V에서 합성한 코팅은 900도 이상에서 26GPa 이상의 높은 경도를 보인 것으로 보아 우수한 내열성을 갖는 것으로 확인 되었다. 이는 AlCrSiN 상부층의 높은 Si 함량 (11at.%) 으로 인한 충분한 $Si_3N_4$ 비정질상의 형성과, 고바이어스 인가로 인한 AlCrN 결정상과 $Si_3N_4$ 비정질상의 고른 분배가 코팅의 내열성을 향상시키는데 기여를 한 결과로 판단된다.

  • PDF

Effect of Various Interlayer Deposition on Room Temperature and High Temperature Properties of CrAlN Coatings (다양한 중간층 증착이 CrAlN 코팅의 상온 및 고온 특성에 미치는 효과에 관한 연구)

  • Kim, Hoe-Geun;Ra, Jeong-Hyeon;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.143-143
    • /
    • 2017
  • CrAlN 코팅은 높은 경도, 낮은 표면 조도 등의 상온에서의 우수한 기계적 특성 이외에 고온에서 안정한 합금상의 형성으로 인하여 우수한 내산화성 및 내열성을 보유하여 공구 코팅으로의 적용 가능성이 크다. 그러나 최근 공구사용 환경의 가혹화로 인하여 코팅의 내마모성 및 내열성 등의 물성 향상을 통한 공구의 수명 향상이 필요시 되고 있으며, 다양한 코팅 물질을 활용하여 다층 코팅을 합성함으로써 난삭재용 공구 코팅의 물성을 높이는 연구들이 진행되고 있다. 본 연구에서는 CrAlN 코팅과 WC-Co 6wt.% 모재 사이에 CrZrN, CrN, CrN/CrZrSiN 등의 중간층을 합성하여 CrAlN 코팅의 상온 및 고온 특성을 향상시키는 연구가 진행되었다. 합성된 코팅의 구조 및 물성을 분석하기 위해 field emission scanning electron microscopy(FE-SEM), nano-indentation, atomic force microscopy(AFM) 및 ball-on-disk wear tester를 사용하였다. 코팅의 고온 특성을 확인하기 위해 코팅을 furnace에 넣어 공기중에서 30분 동안 annealing 한 후에 nano-indentation을 사용하여 경도를 측정하였고, $500^{\circ}C$ annealing 코팅의 표면 조도 분석 및 $500^{\circ}C$에서 마찰마모시험을 실시하였다. CrAlN 코팅의 상온 특성을 분석한 결과, 모든 코팅의 경도(35.5-36.2 GPa)와 탄성계수(424.3-429.2 GPa)는 중간층의 종류에 상관없이 비슷한 값을 보인 것으로 확인됐다. 그러나, CrN/CrZrSiN 중간층을 증착한 CrAlN 코팅의 마찰계수는 0.33로 CrZrN 중간층을 증착한 CrAlN 코팅의 마찰계수(0.41)에 비해 향상된 값 보였으며, 코팅의 마모율 및 마모폭도 비슷한 경향을 보인 것으로 보아 코팅의 내마모성이 향상된 것으로 판단된다. 이것은 중간층의 H/E ratio가 코팅의 내마모성에 미치는 영향에 의한 결과로 사료된다. H/E ratio는 파단시의 최대 탄성 변형율로써, 모재/중간층/코팅의 H/E ratio 구배에 따라 코팅 내의 응력의 완화 정도가 변하게 된다. WC 모재 (H/E=0.040)와 CrAlN 코팅(H/E=0.089) 사이에서 CrN, CrZrSiN 중간층의 H/E ratio는 각각 0.076, 0.083 으로 모재/중간층/코팅의 H/E ratio 구배가 점차 증가함을 확인 할 수 있었고, 일정 응력이 지속적으로 가해지면서 진행되는 마모시험중에 CrN과 CrZrSiN 중간층이 WC와 CrAlN 코팅 사이에서 코팅 내부의 응력구배를 완화시키는 역할을 함으로써 CrAlN 코팅의 내마모성이 향상된 것으로 판단된다. 내열성 시험 결과, CrN/CrZrSiN 중간층을 증착한 코팅은 $1,000^{\circ}C$까지 약 28GPa의 높은 경도를 유지한 것으로 확인 되었다. $500^{\circ}C$ annealing 후 진행된 표면 조도와 마모시험 결과, 모든 코팅의 조도 값 및 마찰계수는 상온 값에 비해 증가하였으며 CrN/CrZrSiN 중간층을 증착한 CrAlN 코팅의 변화량이 가장 낮은 값을 보였다. 이는 CrZrSiN 중간층 내에 존재하는 $SiN_x$ 비정질상이 고온 annealing시에 산소 차폐막 역할을 하여, 코팅내의 잔류 산소에 의한 산화작용을 효과적으로 방지함으로써 코팅의 고온 특성이 향상된 것으로 판단된다.

  • PDF

Concentration of Hazardous Substances of before/after a Decoction in Prescription of Herbal Medicine -In Prescription of tonify Yang and tonify Yin- (한방처방의 전탕 전과 후의 위해물질 농도변화 -보양.보음 처방을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.17 no.2
    • /
    • pp.53-63
    • /
    • 2009
  • Objective : To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods : The heavy metal contents before/after a decoction were measured by Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 4 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Jaeumganghwa-tang (before decoction - Pb; 1.190, Cd; 0.184, As; 0.099 and Hg; 0.028, after decoction - Pb; .033, Cd; 0.003, As; 0.005 and Hg; 0.001), Yukmijiwhang-tang (before decoction - Pb; 0.484, Cd; 0.133, As; 0.053 and Hg; 0.009, after decoction - Pb; 0.065, Cd; 0.008, As; 0.007 and Hg; not detected), Bojungikgi-tang (before decoction - Pb; 0.863, Cd; 0.197, As; below 0.016 and Hg; 0.011, after decoction - Pb; 0.071, Cd; 0.009, As; 0.004 and Hg; 0.001) and Ssangwha-tang (before decoction - Pb; 1.511, Cd; 0.212, As; 0.094 and Hg; 0.016, after decoction - Pb; 0.029, Cd; 0.006, As; 0.005 and Hg; 0.0004). 2. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Jaeumganghwa-tang, Yukmijiwhang-tang and Ssangwha-tang exhibited 22.7, 107.3 and 5.5, respectively. However, contents of sulfur dioxide after a decoction in all samples were not detected. 3. Contents (mg/kg) of residual pesticides before/after a decoction in all samples were not detected. Conclusion : These results will be used to establish a criterion of heavy metals, residual pesticides and sulfur dioxide.

  • PDF

Concentration of Heavy Metals, Residual Pesticides and Sulfur Dioxide before/after a Decoction - In Prescription consist of Sipjeondaebo-tang - (전탕 전과 후의 중금속, 잔류농약 및 잔류이산화황의 농도변화 - 십전대보탕 구성처방을 중심으로 -)

  • Seo, Chang-Seob;Huang, Dae-Sun;Lee, Jun-Kyoung;Ha, Hye-Kyung;Chun, Jin-Mi;Um, Young-Ran;Jang, Seol;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.108-117
    • /
    • 2009
  • Objective: To compare the contents of heavy metals, residual pesticides and sulfur dioxide before/after a decoction. Methods: The heavy metal contents before/after a decoction were measured by inductively-coupled plasma atomic emission spectrometer (ICP-AES) and mercury analyzer. In order to analyze pesticides in 5 samples we used simultaneous multi-residue analysis of pesticides by GC/ECD, which was followed by GC/MSD analysis to confirm the identity of the detected pesticide in each sample. In addition, the contents of sulfur dioxide ($SO_2$) were performed by Monier-Williams distillation method. Results: 1. The mean values of heavy metal contents (mg/kg) for the samples were as follows: Sipjeondaebo-tang (before decoction - Pb; 1.163, Cd; 0.257, As; 0.080 and Hg; 0.016, after decoction - Pb; 0.059, Cd; 0.007, As; 0.006 and Hg; 0.0003), Palmul-tang (before decoction - Pb; 1.181, Cd; 0.242, As; 0.152 and Hg; 0.014, after decoction - Pb; 0.067, Cd; 0.008, As; 0.008 and Hg; 0.0003), Sagunja-tang (before decoction - Pb; 1.285, Cd; 0.283, As; 0.063 and Hg; 0.012, after decoction - Pb; 0.047, Cd; 0.009, As; 0.004 and Hg; not detected) and Samul-tang (before decoction - Pb; 1.025, Cd; 0.169, As; 0.099 and Hg; 0.013, after decoction - Pb; 0.065, Cd; 0.007, As; 0.010 and Hg; 0.001). 2. Contents (mg/kg) of residual pesticides before/after a decoction were not detected in any samples. 3. Contents (mg/kg) of sulfur dioxide ($SO_2$) before a decoction in Sipjeondaebo-tang, Palmul-tang, Sagunja-tang and Samul-tang exhibited 5.0, 6.0, 14.0 and 6.9, respectively. However, contents of sulfur dioxide after a decoction were not detected in any samples. Conclusion: These results will be used to establish a criterion for heavy metals, residual pesticides and sulfur dioxide.

  • PDF

Determination of boron in steel by HNO3-NH4HF2 digestion and ICP-MS (질산-이플루오린화암모늄 분해 및 ICP-MS에 의한 철강 중 붕소 정량에 관한 연구)

  • Choi, Won Myung;Eum, Chul Hun;Park, Ilyong
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.352-356
    • /
    • 2014
  • Various studies have been done to improve the properties of the steel by adding boron to the steel. Some studies have reported on the analysis of the boron in steel by AAS (atomic absorption spectrometry), ICP-OES(inductively coupled plasma-optical emission spectrometry), ICP-MS (inductively coupled plasma/mass spectrometry). The volatile loss of boron of steel in sample digestion and the separation procedure for avoiding matrix effect by high concentration of iron are difficulties for determination of boron in steel. The method to determine boron in steel by ICP-MS was developed without volatilization of boron in sample digestion step with $HNO_3-NH_4HF_2$ digestion method, and the additional separation process for avoiding matrix effect. Complete decomposition of steel with $HNO_3-NH_4HF_2$ digestion method, and boron determination by ICP-MS in the matrix of high concentration of iron were possible. Quantitative recoveries of boron in certified standard steel by new method in this study were 103 to 111%, and the relative standard deviation is less than 5%. The method detection limit was $1.17{\mu}g/g$.

Formation and Characteristics of the Fluorocarbonated SiOF Film by $O_2$/FTES-Helicon Plasma CVD Method

  • Kyoung-Suk Oh;Min-Sung Kang;Chi-Kyu Choi;Seok-Min Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.77-77
    • /
    • 1998
  • Present silicon dioxide (SiOz) 떠m as intennetal dielectridIMD) layers will result in high parasitic c capacitance and crosstalk interference in 비gh density devices. Low dielectric materials such as f f1uorina뼈 silicon oxide(SiOF) and f1uoropolymer IMD layers have been tried to s이ve this problem. I In the SiOF ftlm, as fluorine concentration increases the dielectric constant of t뼈 film decreases but i it becomes unstable and wa않r absorptivity increases. The dielectric constant above 3.0 is obtain어 i in these ftlms. Fluoropolymers such as polyte$\sigma$따luoroethylene(PTFE) are known as low dielectric c constant (>2.0) materials. However, their $\alpha$)Or thermal stability and low adhesive fa$\pi$e have h hindered 야1리ru뚱 as IMD ma따"ials. 1 The concept of a plasma processing a찌Jaratus with 비gh density plasma at low pressure has r received much attention for deposition because films made in these plasma reactors have many a advantages such as go여 film quality and gap filling profile. High ion flux with low ion energy in m the high density plasma make the low contamination and go어 $\sigma$'Oss피lked ftlm. Especially the h helicon plasma reactor have attractive features for ftlm deposition 야~au똥 of i앙 high density plasma p production compared with other conventional type plasma soun:es. I In this pa야Jr, we present the results on the low dielectric constant fluorocarbonated-SiOF film d밑JOsited on p-Si(loo) 5 inch silicon substrates with 00% of 0dFTES gas mixture and 20% of Ar g gas in a helicon plasma reactor. High density 띠asma is generated in the conventional helicon p plasma soun:e with Nagoya type ill antenna, 5-15 MHz and 1 kW RF power, 700 Gauss of m magnetic field, and 1.5 mTorr of pressure. The electron density and temperature of the 0dFTES d discharge are measUI벼 by Langmuir probe. The relative density of radicals are measured by optic허 e emission spe따'Oscopy(OES). Chemical bonding structure 3I피 atomic concentration 따'C characterized u using fourier transform infrared(FTIR) s야3띠"Oscopy and X -ray photonelectron spl:’따'Oscopy (XPS). D Dielectric constant is measured using a metal insulator semiconductor (MIS;AVO.4 $\mu$ m thick f fIlmlp-SD s$\sigma$ucture. A chemical stoichiome$\sigma$y of 야Ie fluorocarbina$textsc{k}$영-SiOF film 따~si야영 at room temperature, which t the flow rate of Oz and FTES gas is Isccm and 6sccm, res야~tvely, is form려 야Ie SiouFo.36Co.14. A d dielec$\sigma$ic constant of this fIlm is 2.8, but the s$\alpha$'!Cimen at annealed 5OOt: is obtain려 3.24, and the s stepcoverage in the 0.4 $\mu$ m and 0.5 $\mu$ m pattern 킹'C above 92% and 91% without void, res야~tively. res야~tively.

  • PDF

Electrical and optical properties of Ag/ZnO multilayer thin film by the FTS (FTS법으로 제작한 Ag/ZnO 박막의 전기적, 광학적 특성)

  • Rim, Y.S.;Kim, S.M.;Son, I.H.;Lee, W.J.;Choi, M.K.;Kim, K.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.2
    • /
    • pp.102-108
    • /
    • 2008
  • We have studied the properties of Ag/undoped ZnO (ZnO) multilayer thin films deposited on glass substrate by the facing targets sputtering method. In an attempt to find out the optimum conditions of the Ag thin film, which would be coated on the ZnO thin film, we investigated the changes of sheet resistance, transmittance and surface morphology as a function of deposition times and the substrate temperature. The electrical and optical characteristics of Ag/ZnO multilayers were evaluated by a four-point probe, a UV/VIS spectrometer with a spectral range of 390-770 nm, a X-ray Diffractometer (XRD), an atomic force microscope (AFM) and a Field Emission Scanning Electron Microscope (SEM), respectively. We were able to prepare the Ag/ZnO multilayer thin film with sheet resistance of 9.25 $\Omega/sq.$ and transmittance of over 80% at 550nm.

Influence of Nanostructured TiO2 Electrode Fabricated with Acid-treated Paste on the Photovoltaic Efficiency of Dye-Sensitized Solar Cells (산처리된 페이스트로 제조한 나노 구조체 TiO2 전극이 염료감응형 태양전지의 효율에 미치는 영향)

  • Lee, Jae-Wook;Hwang, Kyung-Jun;Roh, Sung-Hee;Kim, Sun-Il
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.356-360
    • /
    • 2007
  • Recently, dye sensitized solar cells (DSSCs) composed of nanoporous $TiO_2$, light-sensitive dyes, electrolytes, and counter electrode have been received much attention. Nanostructured particles with higher surface area for the higher adsorption of Ru (II) dye are required to increase the quantity of light absorption. Also, it has been reported that the key factor to achieve high energy conversion efficiency in the photoelectrode of DSSC is the heat treatment of $TiO_2$ paste with acid addition. In this work, we investigated the influence of acid treatment of $TiO_2$ solar cell on the photovoltaic performance of DSSC. The working electrodes fabricated in this work were characterized by X-ray photoelectron spectroscopy (XPS), extended X-ray absorption fine structure (EXAFS), field emission scanning electron microscope (FE-SEM), and atomic force microscope (AFM). In addition, the influence of nanostructured photoelectrode fabricated with the acid-treated paste on the energy conversion efficiency was investigated on the basis of photocurrent-potential curves. It was found that the influence of acid-treated paste on the photovoltaic efficiency was significant.

Application of Laser-Induced Breakdown Spectroscopy (LIBS) for In-situ Detection of Heavy Metals in Soil (토양내 중금속 실시간 탐지를 위한 레이저 유도붕괴 분광법의 활용에 대한 소개)

  • Ko, Eun-Joung;Hamm, Se-Yeong;Kim, Kyoung-Woong
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.563-574
    • /
    • 2007
  • Laser induced breakdown spectroscopy (LIBS) is a recently developed analytical technique that is based upon the measurement of emission lines generated by atomic species close to the surface of the sample, thus allowing their chemical detection, identification and quantification. With powerful advantages of LIBS compared to the conventional analytical methodology, this technique can be applied in the detection of heavy metals in the field. LIBS allows the rapid analysis by avoiding laborious chemical steps. LES have already been applied for the determination of element concentration in a wide range of materials in the solid, liquid and gaseous phase with simplicity of the instrument and diversity of the analytical application. These feasibility of rapid multi elemental analysis are appealing proprieties for the in-situ analytical technique in geochemical investigation, exploration and environmental analysis. There remain still some limitations to be solved for LIBS to be applied in soil environment as an in-situ analytical technology. We would like to provide the basic principle related to the plasma formation and laser-induced breakdown of sample materials. In addition, the matrix effect, laser properties and the various factors affecting on the analytical signal of LIBS was dealt with to enhance understanding of LIBS through literature review. Ultimately, it was investigated the feasibility of LIBS application in soil environment monitoring by considering the basic idea to enhance the data quality of LIBS including the calibration method for the various effects on the analytical signal of LIBS.