• 제목/요약/키워드: Atomic absorption analysis

검색결과 274건 처리시간 0.028초

저온 ALD로 제조된 TiO2 나노 박막 물성 연구 (Property of the Nano-Thick TiO2 Films Using an ALD at Low Temperature)

  • 윤기정;송오성
    • 한국재료학회지
    • /
    • 제18권10호
    • /
    • pp.515-520
    • /
    • 2008
  • We fabricated 10 nm-$TiO_2$ thin films for DSSC (dye sensitized solar cell) electrode application using ALD (atomic layer deposition) method at the low temperatures of $150^{\circ}\;and\;250^{\circ}$. We characterized the crosssectional microstructure, phase, chemical binding energy, and absorption of the $TiO_2$ using TEM, HRXRD, XPS, and UV-VIS-NIR, respectively. TEM analysis showed a 10 nm-thick flat and uniform $TiO_2$ thin film regardless of the deposition temperatures. Through XPS analysis, it was found that the stoichiometric $TiO_2$ phase was formed and confirmed by measuring main characteristic peaks of Ti $2p^1$, Ti $2p^3$, and O 1s indicating the binding energy status. Through UV-VIS-NIR analysis, ALD-$TiO_2$ thin films were found to have a band gap of 3.4 eV resulting in the absorption edges at 360 nm, while the conventional $TiO_2$ films had a band gap of 3.0 eV (rutile)${\sim}$3.2 eV (anatase) with the absorption edges at 380 nm and 410 nm. Our results implied that the newly proposed nano-thick $TiO_2$ film using an ALD process at $150^{\circ}$ had almost the same properties as thsose of film at $250^{\circ}$. Therefore, we confirmed that the ALD-processed $TiO_2$ thin film with nano-thickness formed at low temperatures might be suitable for the electrode process of flexible devices.

Chemical Compositions and Pyrolysis Characteristics of Oil Shales Distributed in Korea

  • Yang, Moon Yul;Yang, Myoung Kee;Lee, Sang Hak;Wakita, Hisanobu
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.487-492
    • /
    • 1995
  • The chemical compositions and pyrolysis characteristics of oil shales and source rocks distributed in the southwestern and southeastern parts of the Korean peninsular have been investigated. In order to compare the results of Korean samples with those of shales giving high oil yields, two Colorado oil shale samples and one Paris source rock samples were also investigated. Chemical compositions of the samples were analysed by means of gravimetry, CHN analysis, X-ray diffraction method, inductively coupled plasma atomic emission spectrometry and atomic absorption spectrometry. A custom made pyrolyser and a Rock-Eval system were used for the pyrolysis studies. Pyrolyses of the samples were carried out by means of a temperature controlling device to $600^{\circ}C$ at a heating rate of $5^{\circ}C/min$ with a helium flow rate of $1200m{\ell}/min$. The results of pyrolysis study indicated that Colorado shale samples belong to type I and all the other samples belong to type II.

  • PDF

Study on production process of graphite for biological applications of 14C-accelerator mass spectrometry

  • Ha, Yeong Su;Kim, Kye-Ryung;Cho, Yong-Sub;Choe, Kyumin;Kang, Chaewon
    • 대한방사성의약품학회지
    • /
    • 제6권1호
    • /
    • pp.20-26
    • /
    • 2020
  • Accelerator mass spectrometry (AMS) is a powerful detection technique with the exquisite sensitivity and high precision compared with other traditional analytical techniques. Accelerator mass spectrometry can be widely applied in the technique of radiocarbon dating in the fields of archeology, geology and oceanography. The ability of accelerator mass spectrometry to measure rare 14C concentrations in microgram and even sub-microgram amounts suggests that extension of 14C-accelerator mass spectrometry to biomedical field is a natural and attractive application of the technology. Drug development processes are costly, risky, and time consuming. However, the use of 14C-accelerator mass spectrometry allows absorption, distribution, metabolism and excretion (ADME) studies easier to understand pharmacokinetics of drug candidates. Over the last few decades, accelerator mass spectrometry and its applications to preclinical/clinical trials have significantly increased. For accelerator mass spectrometry analysis of biological samples, graphitization processes of samples are important. In this paper, we present a detailed sample preparation procedure to apply to graphitization of biological samples for accelerator mass spectrometry.

동적섭식경로모델 DYNACON에 대한 입력변수의 민감도분석 (Sensitivity Analysis of Input Parameters for a Dynamic Food-Chain Model DYNACON)

  • 황원태;이근창;한문회;조규성
    • Journal of Radiation Protection and Research
    • /
    • 제25권1호
    • /
    • pp.11-19
    • /
    • 2000
  • 동적섭식경로모델 DYNACON에 대한 입력변수의 민감도 분석을 장반감기 핵종 $(^{137}Cs,\;^{90}Sr)$에 대해 침적시점의 함수로 평가하였다. 또한 장, 단기간 음식물 (곡류, 엽채류, 우유) 오염에 대한 입력변수의 영향이 고찰되었다. 입력변수는 LHS 기법으로 표본 추출되었으며, 민감도 지수는 PRCC로 나타냈다. 핵종과 음식물의 종류에 따른 민감도 지수는 침적시점 뿐 아니라 장, 단기간 오염에 있어서도 뚜렷이 다르게 나타났다. 작물의 성장기 침적의 경우 장, 단기간 오염 모두 잎흡수에 의한 오염 관련변수가 중요하였다. 또한 작물의 비성장기 침적의 경우 단기간 오염에 있어서도 잎흡수에 의한 오염 관련변수가 중요하였다. 장기간 오염의 경우 잎흡수에 의한 오염 관련변수의 영향은 줄고 뿌리흡수에 의한 오염 관련변수의 영향이 증가하였다. 특히 이러한 현상은 작물의 성장기 침적에 비해 비성장기 침적의 경우에, $^{l37}Cs$ 침적에 비해 $^{90}Sr$ 침적의 경우에 보다 뚜렷하였다. 목초의 성장기 침적의 경우 우유로의 핵종 전달계수, 젖소의 일일 목초 섭취량과 같은 가축 특성 관련변수가 상대적으로 우유의 오염에 중요한 입력변수로 나타났다.

  • PDF

대전.충청 지역 초.중학교 급식의 나트륨, 칼륨 함량 및 섭취량 조사 (Survey on Sodium and Potassium Content of School Meals as well as Sodium and Potassium Intake by Students in the Daejeon and Chungcheong Area)

  • 이은미;박유경;정우영;김미라;서은채;정래석;나미애;이진하;허옥순
    • 동아시아식생활학회지
    • /
    • 제20권6호
    • /
    • pp.853-862
    • /
    • 2010
  • This study was conducted as a nationwide project in order to obtain data on the content and intake of sodium in school meals. For this purpose, we selected two elementary and two middle schools in Daejeon as well as four elementary schools in the Chungcheong area. We measured the sodium and potassium contents of 842 dishes as well as their intake levels over 154 days. Sodium content was analyzed using an AAS (Atomic Absorption Spectrometer). The average meal intakes of second and fifth grade elementary school students were 244 g/meal and 304 g/meal, respectively. The meal intake of middle school students was 401 g/meal. Boys tended to eat slightly more than did girls, and students tended to eat more in the spring than in the summer. The average sodium intake per meal was 642 mg (570 mg by elementary school students, 1068 mg by middle school students), which was 32.1% of the UL (Tolerable Upper Intake Level, 2,000 mg per day) according to the KDRIs (Dietary Reference Intakes for Koreans). The sodium intake per meal was not significantly differ between boys and girls or between spring and summer (p>0.05). This study provides fundamental data that can be used to establishment a nutrition policy concerning the adequate content of sodium in school meals.

용매 추출법에 의한 폐수중 6가크롬의 원자흡수 분광분석에 관한 연구 (Studies on Atomic Absorption Spectrophotometric Analysis of Hexavalent Chromium in Waste Water by Solvent Extraction)

  • 김응표;김영상
    • 대한화학회지
    • /
    • 제30권5호
    • /
    • pp.423-432
    • /
    • 1986
  • 폐수 중의 6가크롬을 음이온 교환체인 aliquat-336(tri-caprylmethyl ammonium chloride)으로 이온쌍을 형성시켜 유기용매인 p-xylene으로 추출하여 원자흡수분광도법으로 정량하는 방법에 대하여 조사 검토하였다. Toluene을 용매로 사용하여 유기물을 제거한 폐수 100ml를 취하여 염산으로 pH 0.5 되게 산성화시킨 다음 aliquat-336을 0.01M되게 녹인 p-xylene 20ml로 6가크롬을 추출하였다. 표준물첨가법에 의해 air-acetylene 불꽃에서 용매중에 추출된 6가크롬을 정량하였다. Al(III), Fe(III), Cr(III)이온들은 6가크롬의 추출 및 흡광도 측정에 방해 하지 않았으며, Fe(III)이온이 6가크롬을 3가크롬으로 환원시키기 때문이다. 또한 유기물이 존재하면 6가크롬의 흡광도를 감소시키므로 이런 방해유기물을 toluene으로 추출 제거하였다. 최적 조건으로 분석한 결과는 96%이상의 회수율을 보여 주었고 이는 미량 분석에서 정확한 방법이라 할 수 있고, 상대평균편차가 3.95%로서 재현성도 비교적 좋았다.

  • PDF

Preconcentration of Iron(III), Lead(II), Cobalt(II) and Chromium(III) on Amberlite XAD-1180 Resin Loaded with 4-(2-Pyridylazo)-resorcinol (PAR) and Their Determination by FAAS

  • Tokalloglu, Serife;Kartal, Senol
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권9호
    • /
    • pp.1293-1296
    • /
    • 2006
  • In this study, a solid phase extraction method has been developed for the preconcentration and separation of the elements Cr(III), Fe(III), Co(II) and Pb(II) at trace levels by using a column packed with Amberlite XAD-1180 resin loaded with 4-(2-pyridylazo)-resorcinol (PAR) reagent. After preconcentrating, the metals retained on the column were eluted with 20 mL of 3 mol/L $HNO_3$ and then determined by flame atomic absorption spectrometry (FAAS). The factors affecting the recovery of the elements, such as pH, type and concentration of eluent, volume of sample and elution solution, and matrix components, were also ascertained. The recoveries of Cr(III), Fe(III), Co(II) and Pb(II) were found to be $99\;{\pm}\;4,\;97\;{\pm}\;3,\;95\;{\pm}\;3$ and $98\;{\pm}\;4$%, respectively, under the optimum conditions at 95% confidence level and the relative standard deviations found by analyzing of nine replicates were $\leq4.4$%. The preconcentration factors for Cr(III), Fe(III), Co(II) and Pb(II) were found as 75, 125, 50 and 75 respectively. The detection limits (DL, 3s/b) were 3.0 $\mu g/L$ for Cr(III), 1.25 $\mu g/L$ for Fe(III), 3.3 $\mu g/L$ for Co(II), and 7.2 $\mu g/L$ for Pb(II). The recoveries achieved by adding of metals at known concentrations to samples and the analysis results of Buffalo river sediment (RM 8704) show that the described method has a good accuracy. The proposed method was applied to tap water, stream water, salt and street dust samples.

강릉·태백지역 석탄광산의 탄 및 호흡성 탄분진중 금속 농도 비교에 관한 연구 (Determination of Metals of Coal and Respirable Coal Dust in Gangneung and Taebaek Coal Mines)

  • 김해정;최호춘;정호근
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.82-88
    • /
    • 1991
  • Determination of Cu, Fe, Ni, Pb, and Zn concentrations in coal and respirable coal dust were performed by atomic absorption spectrophotometry. The coal samples of 18 coal mines in Gangneung area were collected and 25 coal mines in Taebaek area. Crushed coal samples were divided into three mesh sizes. The results were as follows : 1. Metal concentrations of coals in Gangneung area by sieve sizes( -100/+200 mesh, -200/+325 mesh, -325 mesh) were as follows: Cu ; 20, 18, 19, Fe ; 1,830, 1,765, 1,107, Pb ; 6, 8, 14, Ni ; 17, 17, 14, Zn ; 4, 2, $4{\mu}g/g$, respectively. Metal concentrations in coals in Taebaek area by sieve sizes(-100/+200 mesh, -200/+325 mesh, -325 mesh) were as follows: Cu ; 30, 32, 26, Fe ; 1,741, 1,822, 1,773, Pb ; 8, 9, 7, Ni ; 13, 13, 13, Zn ; 8, 5, $4{\mu}g/g$, respectively. There were not significant differences of Cu, Fe, Ni, Pb, and Zn concentrations of coals statistically in Gangneung and Taebaek area by sieve size. 2. Metal concentrations of coals in Gangneung and Taeback area were as follows : Cu ; 19, 30, Fe ; 1,514, 1,778, Pb ; 9, 8, Ni ; 16, 13, Zn ; 3, $6{\mu}g/g$, respectively. Differences of copper and zinc concentrations of coal samples were significant between Gangneung and Taebaek area, but those of iron, nickel and lead concentrations were not significant. 3. Copper, iron, lead, nickel and zinc concentrations of coals and respirable coal dust were as follows : Cu ; 30, 6, Fe ; 1,779, 5,075, Pb ; 8, 7,814, Ni ; 13, 5,681, Zn ; 5, $134{\mu}g/g$, respectively. Differences of nickel, lead and zinc concentrations were significant between coals and respirable coal dust but those of copper and iron concentrations were not significant.

  • PDF

FAAS를 이용한 혈중 Cisplatin의 분석법 개발 (The Development of Cisplatin Analysis Method in Plasma by Flameless Atomic Absorption Spectrometry)

  • 백만정;임호섭;정미진;이경옥;신호상
    • 분석과학
    • /
    • 제11권4호
    • /
    • pp.243-247
    • /
    • 1998
  • 백금을 함유한 항암제로 신장과 신경계에 심각한 부작용을 일으키는 cisplatin의 혈중 농도를 flameless atomic absorption spectrometry법(FAAS)으로 분석하였다. 이 방법은 시료전처리 과정이 필요 없어 신속하고 간단한 분석법이다. 검정곡선에 대한 직선성을 조사한 결과 20~1000ng/mL 농도 범위에서 r=0.999로 나타났으며, 정확도는 50 ng/mL 이상의 농도에서 상대표준편차가 5.0% 이하 이었다. 그리고, 혈장시료 $200{\mu}L$에 대한 검출한계는 10 ng/mL 이었다. 본 방법은 cisplatin의 최적 치료 조건과 독성 경감을 위한 혈중 모니터링에 그 활용이 크게 기대된다.

  • PDF

흑연로 원자흡수분광법에 의한 혈중 납분석시 매트릭스 변형제의 역할 (The role of matrix modifier for the determination of Lead (Pb) in blood by graphite furnace atomic absorption spectrometry)

  • 유광식;권진기
    • 분석과학
    • /
    • 제5권4호
    • /
    • pp.349-358
    • /
    • 1992
  • 본 연구에서는 흑연로 원자흡수분광법을 이용하여 혈액을 1% Triton X-100을 5배 희석시킨 다음 납 함량을 직접 측정하였다. 혈액내 방해 성분을 제거하기 위하여 매트릭스 변형제를 사용하여 최적의 분석 조건을 조사하였다. 매트릭스 변형제로서 1% $(NH_4)_2HPO_4$와 0.1% $PdCl_2$를 같이 사용하고 700도에서 회화시켰을 때에, 일본 비교 분석 프로그램에 의해 제공된 혈중 납 함량에 대한 정도관리용 표준시료(우혈)의 공인값과 비교적 잘 일치하였다. 이 실험에서 얻은 표준편차는 $31{\mu}gPb/l$에서 $624{\mu}gPb/l$ 범위에서는 1% $(NH_4)_2HPO_4$ 및 1% $(NH_4)_2HPO_4$와 0.1% $PdCl_2$를 매트릭스 변형제로서 사용했을 경우 각각 2.2~6.3%, 3.1~9.1%였다.

  • PDF