• Title/Summary/Keyword: Atomic absorption analysis

Search Result 274, Processing Time 0.025 seconds

EPR Investigation on a Quantitative Analysis of Eu(II) and Eu(III) in LiCl/KCl Eutectic Molten Salt

  • Park, Yong-Joon;Kim, Tack-Jin;Cho, Young-Hwan;Jung, Yong-Ju;Im, Hee-Jung;Song, Kyu-Seok;Jee, Kwang-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.127-129
    • /
    • 2008
  • EPR spectroscopic technique was applied for a quantitative analysis of Eu(II) for a speciation of europium in a LiCl-KCl eutectic melt. By adopting the first absorption line of each isotopes (151Eu and 153Eu), a calibration plot was obtained. The calibration of the EPR intensity shows a good linearity according to the amount of Eu(II). The EPR intensity was identified to increase proportionally with a decrease of the attenuation parameter for EPR microwave power. The fluorescence technique was used qualitatively to find whether either of Eu(II) or Eu(III) ions exists in a molten salt sample. The ICP-AES technique was also adopted to determine the total concentration of europium in the sample, since EPR is only sensitive for detecting the Eu(II) ion. The extent of the reduction of Eu(III) in the LiCl-KCl eutectic melt at 723 K was determined by using this technique.

Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry (Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석)

  • Cheon, Mi-Hee;Kim, Chul;Lee, Hyun-Joo;Kang, Lim-Seok
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.399-406
    • /
    • 2003
  • This study was conducted to find out the analysis condition of selenium(Se) in oil refinery wastewater with a high concentration of Se using the atomic absorption spectrometry with hydride generation system (HG-AAS). From various experiments that reduced Se(VI) to Se(IV), the optimum pretreatment condition was determined to be a sample volume of 10 mL, HCl 10 mL, with a 30 min heating time in a water bath. In oil refinery wastewater, as the concentration of organics and constitution became higher, the recovery rates of Se decreased. Therefore, three acid digestion methods ($HNO_3/HClO_4$ digestion, $KMnO_4$ digestion, and microwave acid digestion) were tested on the recovery rates of Se in reference to the digestion of organics, petroleum and oxidation from organic Se(org.), Se(IV) to Se(VI). The experiment results showed that the average recovery rate of Se was the highest in microwave acid digestion, although all of the digestions were more than 90%. In consequence, the pretreatment procedure of microwave digestion followed by HCl addition was the most suitable for selenium analysis in oil refinery wastewater by using HG-AAS.

The Simultaneous Extraction and Determination of Trace Copper and Zinc in Solvent Extraction (용매추출법에 의한 토양중의 미량 구리와 아연원소의 동시추출 및 정량에 관한 연구)

  • 정창웅;지석주;박종안
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.3
    • /
    • pp.87-95
    • /
    • 1995
  • A rapid and selective co-extraction systems of copper and zinc-thiocyanate complex into various types of alkylamine for the simultaneous determination of two metal ions by atomic absorption spectrometry and ion chromatograph have been proposed. The quantitative extractions of Cu(II) and Zn(II) at 0.1 M-thiocyanate and 0.1 M-HCI were achieved with Aliquat 336-$CHCl_3$. The detection limits of Cu and Zn were 2 ppb and 0.9 ppb respectively.

  • PDF

Determination of Trace Metals in Fel Ursi (시판 웅담의 미량금속 정량에 관한 연구)

  • Lee, Sook-Yun;Yu, Bong-Shin;Mun, Hye-Ryoung;Kim, Sung-Kyung
    • Korean Journal of Pharmacognosy
    • /
    • v.13 no.3
    • /
    • pp.102-105
    • /
    • 1982
  • Nine trace elements in Bear Galls(Fel Ursi) studied in this paper are Na, Mg, K, Ca, Cu, Zn, Fe, Pb and Ge. The contents of Na, Mg, K, Ca, Cu, Zn, Fe, Pb are determined by atomic absorption spectrometry and Ge is determined by graphite atomic absorption spectrometry. In both methods, the sample is digested with nitric-perchloric acid and then ashed. The results of analysis are shown in table and the result obtained from this study are as follows. a. The highest content of trace element of Bear Gall is Na and other elements are getting lower in order of K, Mg, Ca, Ge, Zn, Fe, Cu, and Pb. b. Particularly the content of Ge in Bear Gall was determined.

  • PDF

Determination Of Dissolved Trace Metals In Sea Water By Atomic Absorption Spectrophotometry After Concentration By Fe (III) - APDC Coprecipitation

  • Lee, Dong-Soo;Lee, Soo-Hyung;Kwak, Hi-Sang;Lee, Kwang Woo
    • 한국해양학회지
    • /
    • v.15 no.1
    • /
    • pp.66-70
    • /
    • 1980
  • A method for the determination of dissolved species of Cd, Co, Cu, Ni, Pb and Zn in sea water by flame atomic absorption spectrophotometry (AAS) is described. Prior to analysis by AAS, these elements are concentrated by coprecipitation with iron pyrrolidinedithiocarbamate at pH 3 because of matrix effects and their low concentration levels in sea water. The detection limits are 0.01, 0.04, 0.02, 0.05, 0.08, and 0.03$\mu\textrm{g}$/l, and the relative standard deviations are 1.0, 2.4, 1.3, 2.9, 2.0 and 2.9% for Cd, Co, Cu, Ni, Pb and Zn, respectively. The method is shown to be satisfactory in terms of recovery and precision for the determination of these metals in sea water.

  • PDF

Absorption and Fluorescence Spectra of Dy(Ⅲ) Complexes with Some Terdentate Ligands

  • Jung Seung Hee;Yoon Soo Kyung;Kim Jong Goo;Kang Jun-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.6
    • /
    • pp.650-654
    • /
    • 1992
  • Absorption and fluorescence spectra are reported for four different 1 : 3 $Dy^{3+}$ : ligand systems in aqueous solution under mild alkaline pH conditions. The ligands included in this study are oxidiacetate, dipicolinate, iminodiacetate and methyliminodiacetate. The oscillator strengths for the 4f→4f multiplet-to-multiplet transitions are empirically determined from the absorption spectra and the intensity parameters ${\Omega}_{\lambda}$}(${\lambda}$ = 2, 4, 6) for the systems are also obtained by applying the Judd-Ofelt theorem to the observed oscillator strengths. The values of the intensity parameters for the systems are compared and discussed in terms of ligand structural properties to investigate how the intensity parameters can response to the minor changes in the ligand environment. In addition, the relative oscillator strengths for fluorescence are evaluated and compared to the results obtained from absorption spectra.

Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy (다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정)

  • Park, Sang-Eon;Jung, Do-Young;Kim, Jae-Woo;Ko, Kwang-Hoon;Im, Kwon;Jung, Eui-Chang;Kim, Chul-Joong
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2004
  • Tunable diode laser absorption spectroscopy was performed for analysis of the H$_2$$^{18}$ O/H$_2$$^{16}$ O isotope ratio of a water sample which was enriched by the membrane distillation method. In order to improve the signal-to-noise ratio, the wavelength modulation spectroscopic method was used with a lock-in amplifier. The fringe noise could be suppressed by using the FFT (Fast Fourier Transform) lowpass filter and the optimization of the modulation depth of the laser frequency. The maximum deviation of $\delta$-value was measured to be$\pm$4$\textperthousand$.

The Impact Properties and Wear Resistance of Polybutylene terephthalate (PBT) Cross-linked by Electron Beam Irradiation (전자선 가교된 PBT의 충격 특성 및 내마모 특성 연구)

  • Shin, Bum Sik;Ko, Keum Jin;Jeun, Joon Pyo;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.145-149
    • /
    • 2011
  • Poly(butylenes terephthalate) have made large strides in applications of injection, extrusion, and molding material due to their excellent thermal resistance and appropriate mechanical properties. However, PBT was not hard polymer but a soft polymer which caused low absorption of external energy and the defect of being easily broken with the strong impact. Thus, the electron beam irradiation was carried out over a range of irradiation doses from 100 to 1,000 kGy for enhancing the properties. The decreases of $T_m$, $T_c$, and enthalpy were observed as increasing the absorbed dose in the results of DSC analysis. The improvement in the impact strength of PBT was clearly observed as the absorbed dose was increased. This was probably due to the 3-dimensional network structures, resulting in increasing the absorption of impact energy. In addition, the wear properties had increased at higher than 300 kGy. The negative deviation of weight loss confirmed the improvement of the wear properties of PBT, as evidenced by SEM observation on the wear surfaces.

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE

  • Lee, Jong-Il;Lee, Tae-Young;Kim, Bong-Whan;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.109-114
    • /
    • 2010
  • Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.

Variation of the Detection Efficiency of a HPGe Detector with the Density of the Sample in the Radioactivity Analysis (방사능 분석에서 밀도에 따른 HPGe 검출기의 검출효율 변화)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Jung, Ki-Jung;Oh, Won-Zin;Lee, Kune-Woo
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2005
  • When the low level radioactivity sample is measured, it is required to have many samples. For increase of the sample volume, a scattering and absorbing probability of the emitted gamma-ray in the sample are to be increased. In order to correct the self-absorption effect, the counting efficiency must be calibrated according to a geometrical condition and sample density. But, it is impossible to determine efficiency for counting sample using standard source with the same geometrical condition and density. In this study, the measuring efficiencies were determined with various counting containers and densities. In order to compare the self-absorption effect with the sample density in the various sample container, the variation of the counting efficiency with the densities was investigated by adding NaI, which has high solubility and density. Also, they were compared with Monte Carlo simulation. The self-absorption effect was found to be significant in the low energy region below 0.5 MeV.