• Title/Summary/Keyword: Atomic absorption analysis

Search Result 274, Processing Time 0.023 seconds

Temperature Dependent Cation Distribution in Tb2Bi1Ga1Fe4O12

  • Park, Il-Jin;Park, Chu-Sik;Kang, Kyoung-Soo;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.110-113
    • /
    • 2008
  • In this study, heavy rare earth garnet $Tb_2Bi_1Ga_1Fe_4O_{12}$ powders were fabricated by a sol-gel and vacuum annealing process. The crystal structure was found to be single-phase garnet with a space group of Ia3d. The lattice constant $a_0$ was determined to be 12.465 ${\AA}$. From the analysis of the vibrating sample magnetometer (VSM) hysteresis loop at room temperature, the saturation magnetization and coercivity of the sample are 7.64 emu/g and 229 Oe, respectively. The N$\acute{e}$el temperature($T_N$) was determined to be 525 K. The M$\ddot{o}$ssbauer spectrum of $Tb_2Bi_1Ga_1Fe_4O_{12}$ at room temperature consists of 2 sets of 6 Lorentzians, which is the pattern of single-phase garnet. From the results of the M$\ddot{o}$ssbauer spectrum at room temperature, the absorption area ratios of Fe ions on 24d and 16a sites are 74.7% and 25.3%(approximately 3:1), respectively. These results show that all of the non-magnetic Ga atoms occupy the 16a site by a vacuum annealing process. Absorption area ratios of Fe ions are dependent not only on a sintering condition but also on the temperature of the sample. It can then be interpreted that the Ga ion distribution is dependent on the temperature of the sample. The M$\ddot{o}$ssbauer measurement was carried out in order to investigate the atomic migration in $Tb_2Bi_1Ga_1Fe_4O_{12}$.

Fabrication of an Alternating Multilayer Film of Poly(ethylene-alt-maleic anhydride) and Poly(4-vinyl pyridine) by Layer-by-Layer Self-Assembly Method (Layer-by-Layer 자기조립법에 의한 Poly(ethyiene-alt-maleic anhydride)i Poly(4-vinyl pyrtdine) 다층막 제조)

  • Lee Joon Youl;Hong Sook-Young
    • Polymer(Korea)
    • /
    • v.29 no.4
    • /
    • pp.392-398
    • /
    • 2005
  • Self-assembled multilayer thin films of poly(ethylene-alt-maleic anhydride) (PEMAh) and poly(4-vinyl pyridine) (P4VP) were fabricated by layer-by-layer (LbL) sequential adsorption. Fourier transform infrared (FT-IR) spectroscopic analysis of the self-assembled PEMAh/P4VP multilayer films confirms that the driving forces for the multilayer buildup are the intermolecular hydrogen bonding and electrostatic interactions. The linear increase of absorption peak of P4VP at 256 nm with increasing number of PEMAh/P4VP bilayers indicates that the multilayer buildup is an uniform assembling process. We also investigate the effects of polyelectrolyte concenhation variation of the dipping solution and pH variation of the PEMAh solution on the multilayer film formation. Thickness. adsorbed polyelectrolyte mass and surface roughness of the multilayer films were measured by UV-visible spectroscopy, quartz crystal microbalance (QCM), and atomic force microscopy (AFM), respectively.

An Analysis of U-233 Resonance Absorption

  • Yoo, Kun-Joong;Mann Cho;Kim, Chang H.;Chi, Chang-Yul
    • Nuclear Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.267-275
    • /
    • 1975
  • The low-lying resolved resonance structure of U-233 is investigated in terms of the Adler-Adler multilevel formalism. The resonance capture and fission cross sections of U-233 below 60 eV are calculated using Adlers' effective resonance parameters. The infinite dilution resonance integrals of U-233 are computed with the use of the Alders' parameters adjusted to fit the cross section data. It is found that the agreement of calculations with experiments is generally good over most of the energy region covered. A transformation of the Adlers' multilevel parameters into an equivalent set of the single level pseudoparameters is made for the use of the existing computer codes which are useful in the reactor calculations but do not have capability to use the multilevel parameters. The results of this transformation are presented in the form of a table.

  • PDF

Quantification of Arsenic Species in Some Seafood by HPLC-AFS (HPLC-AFS를 이용한 해산물 중 비소 화학종 분리정량)

  • Jeong, Seung-Woo;Lee, Chae-Hyeok;Lee, Jong-Wha;Jang, Bong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.496-503
    • /
    • 2021
  • Background: Considering the expenses of and difficulties in arsenic speciation by high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), alternative measurement methods should be useful, especially for large-scale research and projects. Objectives: A measurement method was developed for arsenic speciation using HPLC-atomic fluorescence spectrometry (HPLC-AFS) as an alternative to HPLC-ICP-MS. Methods: Total arsenic and toxic arsenic species in some seafoods were determined by atomic absorption spectrometry coupled with hydride vapor generation (AAS-HVG) and HPLC-AFS, respectively. Recovery rate of arsenic species in seafood was evaluated by ultra sonication, microwave and enzyme (pepsin) for the optimal extraction method. Results: Limits of detection of HPLC-AFS for As3+, dimethylarsinate (DMA), monomethylarsonate (MMA) and As5+ were 0.39, 0.53, 0.60 and 0.64 ㎍/L, respectively. The average accuracy ranged from 97.5 to 108.7%, and the coefficient of variation was in the range of 1.2~16.7%. As3+, DMA, MMA and As5+ were detected in kelp, the sum of toxic arsenic in kelp was 40.4 mg/kg. As3+, DMA, MMA and As5+ were not detected in shrimp and squid, but total arsenic (iAS and oAS) content in shrimp and squid analyzed by AAS-HVG were 18.1 and 24.7 mg/kg, respectively. Conclusions: HPLC-AFS was recommendable for the quantitative analysis method of arsenic species. As toxic arsenic species are detected in seaweeds, further researches are needed for the contribution degree of seafood in arsenic exposure.

Seismic Fragility Analysis Considering the Inelastic Behavior of Equipment Anchorages for High-Frequency Earthquakes (고진동수 지진에 대한 기기 정착부의 비탄성 거동을 고려한 지진취약도 평가)

  • Eem, Seunghyun;Kwag, Shinyoung;Choi, In-Kil;Jung, Jae-Wook;Kim, Seokchul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.261-266
    • /
    • 2021
  • Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교)

  • Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kang, Min-Kyung;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.491-501
    • /
    • 2018
  • Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: $0.000{\mu}g/L$, MDL: $0.06{\mu}g/L$) was lower than that of GF-AAS (IDL: $0.085{\mu}g/L$, MDL: $0.327{\mu}g/L$). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ${\pm}30%$ of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Relationship between Heavy Metal Concentrations in the Soil with the Blood and Urine of Residents around Abandoned Metal Mines (폐금속 광산지역 토양 중 중금속 농도와 주민의 혈액 및 요중 중금속 농도와의 관련성)

  • Jang, Bong-Ki;Park, Sang-Il;Kim, Nam-Soo;Jung, Kyung-Sick;Lee, Byung-Kook;Lee, Jong-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.5
    • /
    • pp.348-357
    • /
    • 2011
  • Objectives: This study was conducted in order to examine the relationship between heavy metal concentrations in the soil and the level of heavy metals in the blood or urine of 216 local residents living near abandoned metal mines. Methods: Residents around abandoned metal mines were interviewed about their dietary habits, including seafood consumption, medical history, cigarette smoking, and drug history. Metal concentrations in the soil were determined by atomic absorption spectrophotometer (AA-7000, Shimadzu, Japan). Lead (Pb) and cadmium (Cd) contents in the blood or urine were analyzed by GF-AAS (AA-6800, Shimadzu). Mercury (Hg) contents in the blood were determined by means of a mercury analyzer (SP-3DS, NIC). Arsenic (As) content in the soil and urine were measured by a HG-AAS (hydride vapor generation-atomic absorption spectrophotometer). Results: The heavy metal concentrations in the soil showed a log normal distribution and the geometric means of the four villages were 8.61 mg/kg for Pb, 0.19 mg/kg for Cd, 1.81 mg/kg for As and 0.035 mg/kg for Hg. The heavy metal levels of the 216 local residents showed a regular distribution for Pb, Cd, Hg in the blood and As in the urine. The arithmetic means were 3.37 ${\mu}g$/dl for Pb, 3.07 ${\mu}g$/l for Cd and 2.32 ${\mu}g$/l for Hg, 10.41 ${\mu}g$/l for As, respectively. Conclusions: As a result of multi-variate analysis for the affecting factors on the bodily heavy metal concentrations, gender and concentration in the soil (each, p<0.01) for blood lead levels; gender and smoking status (each, p<0.01) for blood cadmium levels; gender (p<0.01) for urine arsenic levels; gender, age and concentration in the soil (p<0.01) for blood mercury levels were shown to be the affecting factors.

A STUDY OF ION BEAM ASSISTED DEPOSITION(IBAD) OF TiN ON Ni-Cr Be ALLOY FOR SURFACE CHARACTERISTIC (이온빔 보조 증착법에 의한 TiN 박막도포가 니켈-크롬-베릴륨 합금의 표면 성상에 미치는 영향에 관한 연구)

  • Choi, Soo-Young;Lee, Sun-Hyung;Chang, Ik-Tae;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.212-234
    • /
    • 1999
  • Dental restorative materials must have the physical properties to withstand wear and corrosion. Base metal alloys possess better mechanical properties and lower price than the gold alloys. For these reasons such alloys have largely replaced the precious metal alloys. One aspect to con-sider is the release of metal substances to oral environment. The release of elements from dental alloys is a continuing concern because the elements may have the potentially harmful biological effects on local tissues. The purpose of this study was to minimize metal release on the nonprecious metal surfaces by ion beam assisted deposition(IBAD) of titanium nitride (TiN) Ni-Cr-Be alloys with and without TiN coatings were secured in an wear test machine opposing ruby ball to determine their relative resistance to wear with loom, 200m, 300m and 400m sliding distance. And the corrosion behavior of the Ni-Cr-Be alloys with and without TiN coatings and 3 dental noble alloys have been studied. Potentiodynamic curves were used to analyse the corrosion characteristics of the alloys. The measurement of the released Ni and Cr ions was conducted by analysis of the electrolyte solution with atomic absorption spectroscopy. The results were as follows : 1. The critical sliding distance that wore down TiN coatings of $2.5{\mu}m$ thickness in this study condition was 300m. 2. Ion beam assisted deposition of TiN showed a good surface modification with respect to the properties of wear and corrosion resistance. 3. X-ray diffraction showed that the strongest peak of TiN is TiN(111) in the coatings. 4. The release of Ni and Cr ions from alloys measured by means of atomic absorption spectroscopy was reduced by ion beam assisted deposition of TiN.

  • PDF

Geochemistry of Mn Scales Formed in Groundwater in the Damyang Area (담양 지역 음용 지하수에 형성된 망간 스케일에 대한 지구화학)

  • Park, Cheon-Young;Kim, Seoung-Ku;Shin, In-Hyun;Ahan, Kun-Sang;Kim, Young-In
    • Journal of the Korean earth science society
    • /
    • v.27 no.3
    • /
    • pp.313-327
    • /
    • 2006
  • This study investigated the geochernical characteristics of Mn scale formed in groundwater wells at the Damyang area. The composition of Mn scale consists mainly of MnO and $SiO_2$. The content of Mn ranges from56.61wt.% to 68.69wt.%, and $SiO_2$ content ranges from 1.56wt.% to 10.45wt.%. The contents of Mo and Ba in Mn scale increased with increased depth; whereas, the content of Zn and Pb decreased with increased depth. Birnessite, quartz and feldspars were identified in Mn scales using x-ray powder diffraction studies. The IR absorption bands for Mn scales show major absorption band due to OH stretching, adsorbed molecular water, and birnessite stretching, respectively. In the SEM and EDS analysis, the Mn scale consists of botryoidal, spherical, spherulite, and empty straw structure. Those structure may be precipitated simply due to oversaturation with concentrated Mn content or may be formed through biogenic precipitation by Lepthothrix discophora. Under microanalysis using EDS on those structure surface of Mn scales, the Mn atomic percent range from 28 to 44, and such elements revealed the presence of Si, K, Na, Ca, Cl, Cu, Zn, and Ba.

A Comparative Analysis of Whole Blood Cadmium by Atomic Absorption Spectrophotometry with a Graphite Furnace (흑연로 원자흡수분광법에 의한 혈액중 카드뮴 정량분석)

  • Park, Jong An;Oh, Hye Jeong;Lee, Jong Hwa
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.301-312
    • /
    • 1996
  • This study was performed to search a optimal analyzing method of cadmium in whole-blood. Cadmium was determined by graphite furnace atomic absorption spectrometry(GFAAS). We investigated the effect of ashing temperature on the absorbance of cadmium in a simple dilution(ten-fold) method with triton X-100 and matrix modifier methods treated with $NH_4H_2PO_4$(1 and 3%) and $Pd(NO_3)_2$(0.00l and 0.005%) as matrix modifier. We also compared the reported reference values of standard blood with values resulted from optimal analyzing conditions of this study. In case of a simple dilution method, when ashing temperature was set at $450^{\circ}C$, the absorbance of sample and background were $0.334{\pm}0.012$ and $1.382{\pm}0.245$, respectively. Background level was higher than the value(0.8) that can be corrected by $D_2$ background correction method. As ashing temperature was rised to $500^{\circ}C$, the absorbance of sample and background were $0.178{\pm}0.008$ and $0.711{\pm}0.223$ respectively. The higher ashing temperature($450^{\circ}C-650^{\circ}C$) was, the lower the absorbance of sample was. In case of a matrix modifier method with $NH_4H_2PO_4$(1 and 3%), when ashing temperature was rised from $500^{\circ}C$ to $650^{\circ}C$, the absorbance of sample slightly changed. The absorbances of sample at $600^{\circ}C$ were $0.230{\pm}0.017$ and $0.137{\pm}0.012$, respectively. These values were larger than that of simple dilution method. But the absorbance of background was higher than the level that can be corrected by $D_2$ method. In case of a matrix modifier method with $Pd(NO_3)_2$(0.001 and 0.005%), the absorbance of sample and background were higher than those of other methods and were stable and reproducible. When ashing temperature was over $550^{\circ}C$, the absorbance of sample was significantly decreased. In case of 0.005% $Pd(NO_3)_2$ carbon residue remained in graphite tube affected the absorbance of sample and background. From these results, We propose that in case of a simple dilution(ten-fold) method with triton X-100 ashing temperature must be maintained below $400^{\circ}C$. In order to diminish the absorbance of background, the alternative method is attenuation of injection volume or multiplication of dilution ratio. We recommend $Pd(NO_3)_2$ than $NH_4H_2PO_4$ as a matrix modifier. In case of a matrix modifier method with $Pd(NO_3)_2$ ashing temperature might be maintained below $550^{\circ}C$.

  • PDF