• 제목/요약/키워드: Atomic absorption

검색결과 880건 처리시간 0.027초

무염 원자흡광도법과 흡광광도법에 의한 제제중의 Metoclopramide의 정량 (Determination of Metoclopramide by Flameless Atomic Absorption and Spectrophotometry)

  • 박만기;임병연;유경수;용군호
    • 약학회지
    • /
    • 제22권1호
    • /
    • pp.27-32
    • /
    • 1978
  • Metoclopramide reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum of 625mm. The reaction product was insoluble in water but soluble in most organic solvents. 1,2-Dichlorethane was the best extracting solvent among the several organic solvents tested. Metoclopramide can be determinded not only by visible light spectrophotometry but also indirectly by estimation of cobalt in the organic phase by flameless atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of 10$^{-4/}$-10$^{-3}$M by spectrophotometry and 10$^{-5}$-10$^{-4}$M by flameless atomic absorption spectrophotometry. The coefficient of variation by spectrophotometry was 0.9% and that of flameless atomic absorption was 1.8%. There was no interference with excipients, pH, temperature and reaction time. With this method, it is possible to determine accurately metoclopramide and tertiary amines in pharmaceutical preparations.

  • PDF

Magnetic and Photo-catalytic Properties of Nanocrystalline Fe Doped $TiO_2$ Powder Synthesized by Mechanical Alloying

  • Uhm, Y.R.;Woo, S.H.;Lee, M.K.;Rhee, C.K.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.955-956
    • /
    • 2006
  • Fe-doped $TiO_2$ nanopowders were prepared by mechanical alloying (MA) varying Fe contents up to 8.0 wt.%. The UV-vis absorption showed that the UV absorption for the Fe-doped powder shifted to a longer wavelength (red shift). The absorption threshold depends on the concentration of nano-size Fe dopant. As the Fe concentration increased up to 4 wt.%, the UV-vis absorption and the magnetization were increased. The benefical effect of Fe doping for photocatalysis and ferromagnetism had the critical dopant concentration of 4 wt.%. Based on the UV absorption and magnetization, the dopant level is localized to the valence band of $TiO_2$.

  • PDF

Analysis of Acetone Absorption Spectra Using Off-axis Integrated Cavity Output Spectroscopy for a Real-time Breath Test

  • Lim Lee;Yonghee Kim;Byung Jae Chun;Taek-Soo Kim;Seung-Kyu Park;Kwang-Hoon Ko;Ki-Hee Song;Hyunmin Park
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.761-765
    • /
    • 2023
  • We analyzed the absorption spectra of acetone in the 3.37 ㎛ mid-infrared range using the off-axis integrated cavity output spectroscopy technique to develop a real-time, in-line breath analysis device. The linear relationship between acetone concentration and absorption increase was confirmed as 0.32%/ppm, indicating that the developed device allows for a quantitative analysis of acetone concentration in exhaled breath. To further confirm the feasibility of using our device for breath analysis, we measured the acetone concentration of human breath samples at the sub-ppm level.

증기증착 공정 감시를 위한 반도체 레이저 흡수 분광학 (Semiconductor laser-based absorption spectroscopy for monitoring physical vapor deposition process)

  • 정의창;송규석;차형기
    • 한국진공학회지
    • /
    • 제13권2호
    • /
    • pp.59-64
    • /
    • 2004
  • 반도체 레이저를 광원으로 사용하는 원자흡수분광 방법으로 금속증기의 증착 공정을 감시하는 연구를 수행하였다. 전자빔 가열 방식을 이용하여 gadolinium (Gd) 금속을 대량으로 증발시켰다. 파장 영역이 770-794 nm (중심파장 780 nm)인 반도체 레이저빔과 388-396 nm 영역의 제 2 고조파 빔을 진공용기에 입사시켜 증발되는 금속증기의 원자흡수 스펙트럼을 실시간으로 기록하였다. 흡수 스펙트럼을 분석하여 증기의 원자밀도를 구했다. 전자빔 출력을 변화시키면서 측정한 원자밀도를 수정 결정 모니터 장치를 사용하여 측정한 증착률과 비교하였다. 산업적으로 많이 사용되는 Ti 등의 증착 공정 감시에 이 실험에서 구현한 레이저 분광장치를 적용할 수 있다는 것을 제시하였다.

카드뮴의 장내흡수(腸內吸收)에 미치는 해조다당류(海藻多糖類)의 영향 (Effects of Algal Polysaccharides on the Intestinal Absorption of Cadmium in Albino Rat)

  • 김영배;강명희;이서래
    • Journal of Nutrition and Health
    • /
    • 제10권1호
    • /
    • pp.18-21
    • /
    • 1977
  • Effects of alginate and tangle on the suppression of intestinal absorption of heavy metals were tested by albino rats. The absorption of cadmium was suppressed by adding 5% or 10% alginate to the diets contaminated with 5 ppm cadmium, but not by 1% a1ginate or 10% tangle (p<0.05).

  • PDF

카드뮴의 장내흡수(腸內吸收)에 미치는 알진산(酸)의 억제(抑制)효과 (A Suppressive Effect of Alginate on the Intestinal Absorption of Cadmium in vitro)

  • 양재승;한성희;이서래
    • Journal of Nutrition and Health
    • /
    • 제11권3호
    • /
    • pp.9-12
    • /
    • 1978
  • An effect of alginate and seaweeds on the intestinal absorption of cadmium was tested in vitro. The absorption of cadmium was remarkably suppressed by alginate though the effect was not selective toward cadmium or calcium. The suppressive effect was also observed with tangle and laver, differing in some aspects from alginate only.

  • PDF

原子吸光分析에 의한 鋼鐵속에 있는 Cr, Mn 및 Ni 의 定量 (Atomic Absorption Spectrophotometric Analysis of Chromium, Nickel and Manganese in Stainless Steel)

  • 황재영
    • 대한화학회지
    • /
    • 제10권3호
    • /
    • pp.133-135
    • /
    • 1966
  • Stainless steel 속에 들어 있는 chromium, nickel, 및 manganess를 原子吸光分光分析法(atomic absorption spectrophotomer)으로써 보다 빨리 定量할 수 있는 方法을 記述하였다. 現行되고 있는 濕式分析法과 比較한 結果 原子吸光分光分析法도 stainless steel의 分析에 믿을만한 한가지 分析法임을 알게 되었다.

  • PDF

원자흡수법을 이용한 다원소 동시 분석 실험 조건에 관한 기초 특성 연구 (Characterization and Studies of Compromised Experimental Conditions for the Simultaneous Multielemental Analysis by Flame Atomic Absorption Spectrometry)

  • 최성규;이현주;박양순;김효진
    • 약학회지
    • /
    • 제39권2호
    • /
    • pp.148-152
    • /
    • 1995
  • For comparison between the compromised experimental condition and the best conditions for each element by flame atomic absorption spectrometer, the absorbances were measured with changing the burner height and HCL current. The optimum absorbance for simultaneous analysis of 6 elements was observed at 1 mA of HCL current and at 4 mm of burner height except Cr and Co. The stability of flame atomic absorption spectrometer on each element was found to be better than 5%. To investigated the accuracy of this instrument, POSCO RM-07 as a real sample was analysed at these compromised experimental conditions and found to be better than 0.04%.

  • PDF

p-type HPGe 검출기 특성에 따른 밀도 보정인자 의존도 평가 (Dependence Evaluation of the Self-Absorption Correction Factor for p-type High Purity Germanium Detector Characteristics)

  • 장미;지영용;김창종;이완로;강문자
    • 방사성폐기물학회지
    • /
    • 제13권4호
    • /
    • pp.295-300
    • /
    • 2015
  • HPGe 검출기를 이용하여 밀도가 다양한 환경시료에 대한 정밀 분석시 정확한 분석을 위해서는 밀도보정인자가 필요하다. 밀도에 대한 보정인자를 구하기 위해서 본 연구에서는 몬테카를로 코드인 MCNPX 코드를 사용하여 크리스털의 높이, 지름 및 코어의 크기와 같은 특성이 다른 세 대의 p-type HPGe 검출기를 모사하고 밀도 $1g/m^3$의 교정용 표준시료를 이용하여 모델링을 검증하였다. 검증을 통하여 모델링을 확정한 후 0.3, 0.6, 0.9, 1.0, 1.2, $1.5g/m^3$ 밀도를 가진 샘플에 대한 효율을 시뮬레이션하고 밀도보정인자를 도출하였다. 도출된 각 검출기에 대한 밀도보정인자를 비교하였을 때 전 에너지 범위에서 그 차이가 거의 없음을 확인하였으며 이는 검출기의 크리스털과 같은 주요 특성에 대해 밀도보정인자가 독립적임을 의미한다.

흡광광도법 및 원자흡광광도법에 의한 Pipethanate$\cdot$HCl의 정량 (Determination of Pipethanate$\cdot$HCl by Spectrophotometry and Atomic Absorption Spectrophotometry)

  • 이왕규;박만기;김박광;손채연
    • 약학회지
    • /
    • 제27권4호
    • /
    • pp.303-307
    • /
    • 1983
  • Pipethanate*HCl reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum at 626nm. The reaction product was insoluble in water but freely soluble in most organic solvents. 1, 2-Dichloroethane was the best extracting solvent among the several organic solvents. Pipethanate*HCl can be determined not only by the spectrophotometry but also inderectly by estimation of cobalt in the organic phase by atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of $1.0{\times}10^{-3}~4.0{\times}10^{-3}M$ by spectrophotometry and $1.5{\times}10^{-4}~4.0{\times}10^{-4}M$ by atomic absorption spectrophotometry. With this method it was possible to determine pipethanate$\cdot$HCl in the pharmaceutical preparations.

  • PDF