• Title/Summary/Keyword: Atmospheric conditions

Search Result 1,391, Processing Time 0.024 seconds

Dielectric Thin Film Using Atmospheric Pressure Plasma Polymerization

  • Choi, Sung-Lan;Kim, Hong-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1444-1446
    • /
    • 2009
  • The atmospheric pressure plasma polymerization of acrylate monomers was carried out to have dielectrics with easy preparation and high performance. The effects of discharge power, monomer concentration and deposition time on film properties were investigated using various characterization tools. With proper conditions, smooth dielectric layer of 100nm thickness was obtained. Dielectric property as organic dielectric layer has been studied for future applications in organic thin film transistors(OTFT).

  • PDF

Photocatalytic Degradation Characteristics of Organic Compound by Boron-doped TiO2 Catalysts

  • Nam, Chang-Mo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.649-656
    • /
    • 2010
  • Boron-doped $TiO_2$ photocatalysts were synthesized by a modified sol-gel method and their photocatalytic activities were performed and compared with those of pure synthetic and commercial $TiO_2$ catalysts under UV or visible light conditions. Pure $TiO_2$ itself exhibited very negligible photocatalytic performance under visible light conditions in the aspects of toluene decomposition reactions, although significant decomposition potential was observed as expected with UV light conditions. However, boron doping over $TiO_2$ significantly improved photocatalytic activity particularly under visible conditions, where over 95% degradation of toluene was achieved with 1wt% $B-TiO_2$ within 2 hrs. All the decomposition reactions seemed to follow pseudo first-order kinetics. The effects of boron-doping and its characteristics are further discussed through the kinetic studies and comparison of results.

The Effect of Similarity Condition for the Test Results in a Wind Tunnel Test (풍동실험에서 상사조건이 실험결과에 미치는 영향에 관한 연구)

  • 봉춘근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.351-362
    • /
    • 2000
  • To set the similarity conditions between a prototype usually in the field and its reduced-scale model is a crucial part in model tests. No technique is available to keep perfect similarity for this procedure so far. The experimental work using a wind tunnel is not exceptional. based on the field measurements, the effect of stack parameters and wind conditions on the dispersion of stack plume has been investigated in the laboratory. in this paper intensive methodology is focused on matching these similarities. Due to the limitations to keep perfect similarity conditions some simplifications are involved in common. In this study geometric conditions and kinematic conditions using Froude number and Reynolds number have been con-sidered to keep the similarity conditions required. From the tests it is found that the critical Reynolds number (Recrit) is 2,700 when the height of stack discharge is 50mm. The dispersion has a similar trend for the higher Reynolds number than the critical Reynolds number. It is also found that different Froude number does not make any significant influence for the normalized tracer gas concentrations at the recipient providing the same ratio of the wind speed to the discharge speed. No significant effect of stack diameter is observed in the normalized tracer gas concentrations with the same Frounde number. The similarity conditions therefore used in this study are reliable to simulate the conditions in prototype into the wind tunnel tests.

  • PDF

A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement (대기압이 가스유량측정에 미치는 영향에 관한 연구)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.363-369
    • /
    • 2002
  • Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

  • PDF

Determination of Size Distribution of Atmospheric Paticulates in Urban Air Using Andersen Sampler (Andersen 시료채취기를 이용한 도시대기중 부유입자상 물질의 입도분포 측정)

  • 이용근;김만구;원정호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.93-98
    • /
    • 1985
  • Mass size distribution of atmospheric particulates were measured using an Andersen using an Andersen sampler in urban air. The atmospheric particulates were fractionated in eight stages of an Andersen sampler operating at 28.4$\ell/min$ and collected on polyester sheets. A quartz filter was placed behind the last stage collect permeated partculates. The size distribution of atmospheric particulates were divided around 1-2 $\mu$m into two groups, coarse and fine particulates regardless of sampling times. The variation of course particulates concentration was higher than fine particulates among sampling times. Different meterorological conditions and natural phenomena brought high variation of course particulates' concentration. The rain caused removal of coarse particulates seriously and the yellow and may take part in a increase of the course particulates in spring. The average concentration of atmospheric particulates to be collected by Andersen sampler was 170.8 $\mug/m^3$ during 3 times of sampling. Among them the average concentration of atmospheric particulates which could penetrated under a bronchi and alveoli were 70.4$\mug/m^3$ and 36.6$\mug/m^3$ respectively.

  • PDF

RETRIEVAL OF LAND SURFACE TEMPERATURE FROM MTSAT-1R

  • Kwak, Seo-Youn;Suh, Myoung-Seok;Kang, Jeon-Ho;Kwak, Chong-Heum;Kim, Chan-Soo
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.250-252
    • /
    • 2006
  • The land surface temperature (LST) can be defined as a weighted average temperature of components which constitute a pixel. The coefficients of split-window algorithm for MTSAT-1R were obtained by means of a statistical regression analysis from radiative transfer simulations using MODTRAN 4.0 for a wide range of atmospheric, satellite viewing angle (SVA) and lapse rate conditions. 6 types of atmospheric profile data imbedded in the MODTRAN 4 are used for the radiative transfer simulations. The RMSE is clearly larger on warm and humid profiles than cold and dry profiles, especially when the satellite viewing angle and lapse rate are large. The derivation of LST equations according to the atmospheric profiles clearly decreased the RMSE without regard to the SVA and lapse rate. The bias and RMSE are decreased as the more controls factors included. This preliminary result indicates that the characteristics of atmosphere, SVA and lapse rate should be included in the LST equation.

  • PDF

Retrieval of land Surface Temperature from MTSAT-1R

  • Kwak, Seo-Youn;Suh, Myoung-Seok;Kang, Jeon-Ho;Kwak, Chong-Heum;Kim, Chan-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.5
    • /
    • pp.385-388
    • /
    • 2006
  • The land surface temperature (LST) can be defined as a weighted average temperature of components which constitute a pixel. The coefficients of split-window algorithm for MTSAT-1R were obtained by means of a statistical regression analysis from radiative transfer simulations using MODTRAN 4.0 for a wide range of atmospheric, satellite viewing angle (SVA) and lapse rate conditions. 6 types of atmospheric profile data imbedded in the MODTRAN 4 are used for the radiative transfer simulations. The RMSE is clearly larger on warm and humid profiles than cold and dry profiles, especially when the satellite viewing angle and lapse rate are large. The derivation of LST equations according to the atmospheric profiles clearly decreased the RMSE without regard to the SVA and lapse rate. The bias and RMSE are decreased as the more controls factors included. This preliminary result indicates that the characteristics of atmosphere, SVA and lapse rate should be included in the LST equation.

Measurement and Interpretation of Time Variations of Particulate Matter Observed in the Busan Coastal Area in Korea

  • Kim, Cheol-Hee;Son, Hye-Young
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • In order to investigate the effects of local and synoptic meteorological conditions on urban scale particulate air pollutants observed over the Busan coastal area, power spectrum analysis was applied to observed particulate matter with an aerodynamic diameter $\leq10\;{\mu}m$ ($PM_{10}$) for the period from 1 October, 1993 to 31 December, 2004. Fast Fourier Transform (FFT) analysis was used to obtain the hourly mean observed $PM_{10}$ concentrations to identify different periodicity scales of $PM_{10}$ concentrations. The results showed that, aside from the typical and well-known periodicities such as diurnal and annual variations caused by anthropogenic influences, three other significant power spectral density peaks were identified: 7-day, 21-day and 2.25-year periodicities. Cospectrum analysis indicated that the seven-day variations were closely related to the synoptic meteorological conditions such as weak wind speed, which are relevant to the stagnant high pressure system slowly passing through the Korean Peninsula. The intra-seasonal 21-day variation was negatively correlated with wind speed but was consistently positively correlated with relative humidity, which is related to aerosol formation that can be achieved as a result of the hygroscopic characteristics of aerosols. However, the quasibiennial 2.25-year variation was correlated with the frequency of Asian dust occurrence, the periodicities of which have been recorded inter-annually over the Korean Peninsula.

Effect of Atmospheric Pressure Flame Plasma Treatment on Surface and Adhesive Bonding Properties between Steel Plate and Rubber (대기압 화염 플라즈마 처리가 강판의 표면 및 고무와의 접착특성에 미치는 영향)

  • Ryu, Sang-Ryeoul;Lee, Dong-Joo
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • To increase the adhesive strength of acrylonitrile butadiene rubber(NBR) and steel plate, the atmospheric pressure flame plasma(APFP) treatment device is applied. The effect of various conditions(processing velocity and distance) is experimentally investigated to ascertain the optimum conditions to yield the best adhesive properties. It is found that the optimum distance between burner port and steel plate is 40mm and the optimum processing velocity is 50m/min at given condition. When the surface is coated twice with the bonding agent, the adhesion strength of APFP treated steel plate is increased to about 20.5%. It suggests that the surface modification of steel by flame plasma treatment at atmospheric pressure is a proper and applicable method to improve the adhesion strength between steel and rubber.

Optimization of Atmospheric Cold Plasma Treatment with Different Gases for Reduction of Escherichia coli in Wheat Flour

  • Lee, Jeongmin;Park, Seul-Ki;Korber, Darren;Baik, Oon-Doo
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.6
    • /
    • pp.768-775
    • /
    • 2022
  • In this study we aimed to derive the response surface models for Escherichia coli reduction in wheat flour using atmospheric cold plasma (ACP) with three types of gas. The jet-type atmospheric cold plasma wand system was used with a 30 W power supply, and three gases (argon, air, and nitrogen) were applied as the treatment gas. The operating parameters for process optimization considered were wheat flour mass (g), treatment time (min), and gas flow rate (L/min). The wheat flour samples were artificially contaminated with E. coli at a concentration of 9.25 ± 0.74 log CFU/g. ACP treatments with argon, air, and nitrogen resulted in 2.66, 4.21, and 5.55 log CFU/g reduction of E. coli, respectively, in wheat flour under optimized conditions. The optimized conditions to reduce E. coli were 0.5 g of the flour mass, 15 min of treatment time, and 0.20 L/min of nitrogen gas flow rate, and the predicted highest reduction level from modeling was 5.63 log CFU/g.